  • 1. A highly selective thallium(I) electrode based on a thia substituted macrocyclic ionophore.
    Singh AK; Saxena P
    Talanta; 2005 May; 66(4):993-8. PubMed ID: 18970082
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
    Singh AK; Saxena P; Mehtab S; Gupta B
    Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base.
    Gholivand MB; Rahimi-Nasrabadi M; Ganjali MR; Salavati-Niasari M
    Talanta; 2007 Sep; 73(3):553-60. PubMed ID: 19073070
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sub-micro level monitoring of beryllium ions with a novel beryllium sensor based on 2,6-diphenyl-4-benzo-9-crown-3-pyridine.
    Ganjali MR; Rahimi-Nasrabadi M; Maddah B; Moghimi A; Faal-Rastegar M; Borhany S; Namazian M
    Talanta; 2004 Jul; 63(4):899-906. PubMed ID: 18969516
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selective electrochemical sensor for copper (II) ion based on chelating ionophores.
    Singh AK; Mehtab S; Jain AK
    Anal Chim Acta; 2006 Aug; 575(1):25-31. PubMed ID: 17723567
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A PVC-based 1,8-diaminonaphthalen electrode for selective determination of vanadyl ion.
    Akbari A; Mousavi MF; Shamsipur M; Rahmanifar MS
    Talanta; 2003 Jul; 60(4):853-9. PubMed ID: 18969110
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ytterbium-selective polymeric membrane electrode based on substituted urea and thiourea as a suitable carrier.
    Singh AK; Jain AK; Mehtab S
    Anal Chim Acta; 2007 Aug; 597(2):322-30. PubMed ID: 17683746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores.
    Singh AK; Gupta VK; Gupta B
    Anal Chim Acta; 2007 Feb; 585(1):171-8. PubMed ID: 17386662
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine.
    Gupta VK; Singh AK; Gupta B
    Anal Chim Acta; 2006 Aug; 575(2):198-204. PubMed ID: 17723591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A selective membrane electrode for lanthanum(III) ion based on a hexaaza macrocycle derivative as ionophore.
    Singh AK; Saxena P; Mehtab S; Gupta B
    Anal Sci; 2006 Oct; 22(10):1339-44. PubMed ID: 17038773
    [TBL] [Abstract][Full Text] [Related]  

  • 11. PVC-based dicyclohexano-18-crown-6 sensor for La(III) ions.
    Mittal SK; Kumar SK; Sharma HK
    Talanta; 2004 Mar; 62(4):801-5. PubMed ID: 18969365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative study of Ag(I) selective poly(vinyl chloride) membrane sensors based on newly developed Schiff-base lariat ethers derived from 4,13-diaza-18-crown-6.
    Gupta VK; Pal MK; Singh AK
    Anal Chim Acta; 2009 Jan; 631(2):161-9. PubMed ID: 19084621
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nickel(II)-selective sensor based on dibenzo-18-crown-6 in PVC matrix.
    Gupta VK; Goyal RN; Agarwal S; Kumar P; Bachheti N
    Talanta; 2007 Feb; 71(2):795-800. PubMed ID: 19071376
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative studies on Tb (III)-selective PVC membrane sensors.
    Gupta VK; Pal MK; Sharma RA
    Talanta; 2010 Sep; 82(4):1136-42. PubMed ID: 20801309
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle.
    Singh AK; Singh P
    Anal Chim Acta; 2010 Aug; 675(2):170-80. PubMed ID: 20800729
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative study on 2-amino-1,4-naphthoquinone derived ligands as indium (III) selective PVC-based sensors.
    Gupta VK; Hamdan AJ; Pal MK
    Talanta; 2010 Jun; 82(1):44-50. PubMed ID: 20685433
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode.
    Singh AK; Singh P; Bhattacharjee G
    Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Strontium-selective membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides.
    Shamsipur M; Rouhani S; Sharghi H; Ganjali MR; Eshghi H
    Anal Chem; 1999 Nov; 71(21):4938-43. PubMed ID: 21662839
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier.
    Zamani HA; Zanganeh-Asadabadi A; Rohani M; Zabihi MS; Fadaee J; Ganjali MR; Faridbod F; Meghdadi S
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):984-8. PubMed ID: 25427515
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrix.
    Gupta VK; Jain AK; Maheshwari G
    Talanta; 2007 Jun; 72(4):1469-73. PubMed ID: 19071785
    [TBL] [Abstract][Full Text] [Related]  