These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 18970208)

  • 1. Trace metal speciation measurements in waters by the liquid binding phase DGT device.
    Li W; Zhao H; Teasdale PR; Wang F
    Talanta; 2005 Sep; 67(3):571-8. PubMed ID: 18970208
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of polymer-bound Schiff base as a new liquid binding agent of diffusive gradients in thin-films for the measurement of labile Cu²⁺, Cd²⁺ and Pb²⁺.
    Fan HT; Liu JX; Sui DP; Yao H; Yan F; Sun T
    J Hazard Mater; 2013 Sep; 260():762-9. PubMed ID: 23856306
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation of trace metal binding properties of lignin by diffusive gradients in thin films.
    Hojaji E
    Chemosphere; 2012 Sep; 89(3):319-26. PubMed ID: 22608133
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct in situ measurements of labile inorganic and organically bound metal species in synthetic solutions and natural waters using diffusive gradients in thin films.
    Zhang H; Davison W
    Anal Chem; 2000 Sep; 72(18):4447-57. PubMed ID: 11008782
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Trace metal measurements in low ionic strength synthetic solutions by diffusive gradients in thin films.
    Warnken KW; Zhang H; Davison W
    Anal Chem; 2005 Sep; 77(17):5440-6. PubMed ID: 16131050
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Trace metal speciation during dry and wet weather flows in the Tama River, Japan, by using diffusive gradients in thin films (DGT).
    Nyein Aung N; Nakajima F; Furumai H
    J Environ Monit; 2008 Feb; 10(2):219-30. PubMed ID: 18246216
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrations.
    Allan IJ; Knutsson J; Guigues N; Mills GA; Fouillac AM; Greenwood R
    J Environ Monit; 2007 Jul; 9(7):672-81. PubMed ID: 17607387
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of poly (ethyleneimine) solution as a binding agent in DGT technique for measurement of heavy metals in water.
    Sui DP; Fan HT; Li J; Li Y; Li Q; Sun T
    Talanta; 2013 Sep; 114():276-82. PubMed ID: 23953471
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of DGT as a metal speciation technique for municipal wastes and aqueous mine effluents.
    Yapici T; Fasfous II; Murimboh J; Chakrabarti CL
    Anal Chim Acta; 2008 Aug; 622(1-2):70-6. PubMed ID: 18602536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of diffusive gradients in thin films (DGT) technique for speciation of trace metals in estuarine waters - A multimethodological approach.
    Cindrić AM; Marcinek S; Garnier C; Salaün P; Cukrov N; Oursel B; Lenoble V; Omanović D
    Sci Total Environ; 2020 Jun; 721():137784. PubMed ID: 32172124
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sodium polyacrylate as a binding agent in diffusive gradients in thin-films technique for the measurement of Cu2+ and Cd2+ in waters.
    Fan H; Sun T; Li W; Sui D; Jin S; Lian X
    Talanta; 2009 Oct; 79(5):1228-32. PubMed ID: 19635351
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of diffusive gradients in thin films and tangential flow ultrafiltration for fractionation of Al(III) and Cu(II) in organic-rich river waters.
    Tonello PS; Rosa AH; Abreu CH; Menegário AA
    Anal Chim Acta; 2007 Aug; 598(1):162-8. PubMed ID: 17693321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Kinetic studies of Ni organic complexes using diffusive gradients in thin films (DGT) with double binding layers and a dynamic numerical model.
    Shafaei Arvajeh MR; Lehto N; Garmo ØA; Zhang H
    Environ Sci Technol; 2013 Jan; 47(1):463-70. PubMed ID: 23153338
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Application of a poly(4-styrenesulfonate) liquid binding layer for measurement of Cu2+ and Cd2+ with the diffusive gradients in thin-films technique.
    Li W; Teasdale PR; Zhang S; John R; Zhao H
    Anal Chem; 2003 Jun; 75(11):2578-83. PubMed ID: 12948123
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diffusive gradients in thin films technique for uranium measurements in river water.
    Li W; Li C; Zhao J; Cornett RJ
    Anal Chim Acta; 2007 May; 592(1):106-13. PubMed ID: 17499077
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a miniaturized diffusive gradients in thin films (DGT) device.
    Alexa N; Zhang H; Lead JR
    Anal Chim Acta; 2009 Nov; 655(1-2):80-5. PubMed ID: 19925919
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of binding of metals to the hydrogel and filter membrane on the accuracy of the diffusive gradients in thin films technique.
    Garmo ØA; Davison W; Zhang H
    Anal Chem; 2008 Dec; 80(23):9220-5. PubMed ID: 19551987
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Copper complexation by tannic acid in aqueous solution.
    Kraal P; Jansen B; Nierop KG; Verstraten JM
    Chemosphere; 2006 Dec; 65(11):2193-8. PubMed ID: 16837024
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of DGT as a metal speciation tool in wastewater.
    Buzier R; Tusseau-Vuillemin MH; Mouchel JM
    Sci Total Environ; 2006 Apr; 358(1-3):277-85. PubMed ID: 16213006
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effective concentration difference model to study the effect of various factors on the effective diffusion coefficient in the dialysis membrane.
    Chen H; Sun T; Sui D; Dong J
    Anal Chim Acta; 2011 Jul; 698(1-2):27-35. PubMed ID: 21645656
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.