BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 18970465)

  • 1. Determination of atrazine and simazine in environmental water samples using multiwalled carbon nanotubes as the adsorbents for preconcentration prior to high performance liquid chromatography with diode array detector.
    Zhou Q; Xiao J; Wang W; Liu G; Shi Q; Wang J
    Talanta; 2006 Feb; 68(4):1309-15. PubMed ID: 18970465
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of bamboo charcoal as solid-phase extraction adsorbent for the determination of atrazine and simazine in environmental water samples by high-performance liquid chromatography-ultraviolet detector.
    Zhao RS; Yuan JP; Jiang T; Shi JB; Cheng CG
    Talanta; 2008 Aug; 76(4):956-9. PubMed ID: 18656684
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of atrazine and simazine in water samples by high-performance liquid chromatography after preconcentration with heat-treated diatomaceous earth.
    Katsumata H; Kaneco S; Suzuki T; Ohta K
    Anal Chim Acta; 2006 Sep; 577(2):214-9. PubMed ID: 17723674
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Using multi-walled carbon nanotubes as solid phase extraction adsorbents to determine dichlorodiphenyltrichloroethane and its metabolites at trace level in water samples by high performance liquid chromatography with UV detection.
    Zhou Q; Xiao J; Wang W
    J Chromatogr A; 2006 Sep; 1125(2):152-8. PubMed ID: 16797570
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simultaneous determination of pesticides at trace levels in water using multiwalled carbon nanotubes as solid-phase extractant and multivariate calibration.
    Al-Degs YS; Al-Ghouti MA; El-Sheikh AH
    J Hazard Mater; 2009 Sep; 169(1-3):128-35. PubMed ID: 19395164
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sensitive determination of fungicides and prometryn in environmental water samples using multiwalled carbon nanotubes solid-phase extraction cartridge.
    Zhou Q; Xiao J; Ding Y
    Anal Chim Acta; 2007 Oct; 602(2):223-8. PubMed ID: 17933607
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multiwalled carbon nanotubes as adsorbents of solid-phase extraction for determination of polycyclic aromatic hydrocarbons in environmental waters coupled with high-performance liquid chromatography.
    Wang WD; Huang YM; Shu WQ; Cao J
    J Chromatogr A; 2007 Nov; 1173(1-2):27-36. PubMed ID: 17977550
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of pesticides residues in environmental water samples using multiwalled carbon nanotubes dispersive solid-phase extraction.
    González-Curbelo MÁ; Herrera-Herrera AV; Hernández-Borges J; Rodríguez-Delgado MÁ
    J Sep Sci; 2013 Feb; 36(3):556-63. PubMed ID: 23303564
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of trace organophosphorus pesticides in water samples with TiO2 nanotubes cartridge prior to GC-flame photometric detection.
    Huang Y; Zhou Q; Xiao J; Xie G
    J Sep Sci; 2010 Jul; 33(14):2184-90. PubMed ID: 20533349
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preconcentration sensitive determination of pyrethroid insecticides in environmental water samples with solid phase extraction with SiO2 microspheres cartridge prior to high performance liquid chromatography.
    Zhou Q; Gao Y; Bai H; Xie G
    J Chromatogr A; 2010 Jul; 1217(31):5021-5. PubMed ID: 20591434
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of magnetic multiwalled carbon nanotubes as solid-phase extraction technique for the determination of p-hydroxybenzoates in beverage.
    Huang D; Fu C; Li Z; Deng C
    J Sep Sci; 2012 Jul; 35(13):1667-74. PubMed ID: 22761146
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitive determination of amide herbicides in environmental water samples by a combination of solid-phase extraction and dispersive liquid-liquid microextraction prior to GC-MS.
    Zhao RS; Diao CP; Chen QF; Wang X
    J Sep Sci; 2009 Apr; 32(7):1069-74. PubMed ID: 19266545
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Flow-through dispersed carbon nanofiber-based microsolid-phase extraction coupled to liquid chromatography for automatic determination of trace levels of priority environmental pollutants.
    Boonjob W; Miró M; Segundo MA; Cerdà V
    Anal Chem; 2011 Jul; 83(13):5237-44. PubMed ID: 21553915
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Application of NaClO-treated multiwalled carbon nanotubes as solid phase extraction sorbents for preconcentration of trace 2,4-dichlorophenoxyacetic acid in aqueous samples.
    Lu P; Deng D; Ni X
    J Sep Sci; 2012 Sep; 35(17):2307-12. PubMed ID: 22807406
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Powdered activated carbons as effective phases for bar adsorptive micro-extraction (BAμE) to monitor levels of triazinic herbicides in environmental water matrices.
    Neng NR; Mestre AS; Carvalho AP; Nogueira JM
    Talanta; 2011 Feb; 83(5):1643-9. PubMed ID: 21238763
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of micro-solid phase extraction with titanate nanotube array modified by cetyltrimethylammonium bromide for sensitive determination of polycyclic aromatic hydrocarbons from environmental water samples.
    Huang Y; Zhou Q; Xie G
    J Hazard Mater; 2011 Oct; 193():82-9. PubMed ID: 21807462
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of oxidation and dimensions of multi-walled carbon nanotubes on solid phase extraction and enrichment of some pesticides from environmental waters prior to their simultaneous determination by high performance liquid chromatography.
    El-Sheikh AH; Insisi AA; Sweileh JA
    J Chromatogr A; 2007 Sep; 1164(1-2):25-32. PubMed ID: 17673220
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of multiwalled carbon nanotubes and a conventional absorbent on the enrichment of sulfonylurea herbicides in water samples.
    Zhou Q; Xiao J; Wang W
    Anal Sci; 2007 Feb; 23(2):189-92. PubMed ID: 17297231
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of atrazine and simazine in environmental water samples by dispersive liquid-liquid microextraction with high performance liquid chromatography.
    Zhou Q; Pang L; Xie G; Xiao J; Bai H
    Anal Sci; 2009 Jan; 25(1):73-6. PubMed ID: 19139576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of sensitive determination method for fungicides from environmental water samples with Titanate nanotube array micro-solid phase extraction prior to high performance liquid chromatography.
    Huang Y; Zhou Q; Xie G
    Chemosphere; 2013 Jan; 90(2):338-43. PubMed ID: 22921656
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.