These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

294 related articles for article (PubMed ID: 18976778)

  • 1. An unusual presentation of implantable cardioverter-defibrillator lead perforation.
    Crusio RH; Greenberg YJ
    J Electrocardiol; 2009; 42(3):265-6. PubMed ID: 18976778
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.
    Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Management of traumatic implantable cardioverter defibrillator lead perforation of the right ventricle after car accident: a case report.
    Sassone B; Gabrieli L; Boggian G; Pilato E
    Europace; 2009 Jul; 11(7):961-2. PubMed ID: 19451098
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Asymptomatic right ventricular perforation by an implantable cardioverter defibrillator lead detected by home monitoring system.
    Migliore F; Leoni L; Torregrossa G; Guglielmi C; Tarantini G; Buja G; Iliceto S; Corrado D
    J Electrocardiol; 2010; 43(6):673-5. PubMed ID: 20888001
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Right ventricular perforation with an ICD defibrillation lead managed by surgical revision and epicardial leads--case reports.
    Krivan L; Kozák M; Vlasínová J; Sepsi M
    Pacing Clin Electrophysiol; 2008 Jan; 31(1):3-6. PubMed ID: 18181900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Delayed cardiac perforation by defibrillator lead placed in the right ventricular outflow tract resulting in massive pericardial effusion.
    Lau EW; Shannon HJ; McKavanagh P
    Pacing Clin Electrophysiol; 2008 Dec; 31(12):1646-9. PubMed ID: 19067821
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Subacute implantable cardioverter defibrillator lead perforation: a potentially life-threatening event.
    Tavernier R; Duytschaever M; Dossche K; Verleyen D; Van Den Brande F; De Greef Y; Vandekerckhove Y
    Europace; 2009 Jul; 11(7):966-7. PubMed ID: 19406850
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Re: Implantable cardioverter-defibrillator.
    Mond HG
    Pacing Clin Electrophysiol; 2008 Apr; 31(4):517. PubMed ID: 18373777
    [No Abstract]   [Full Text] [Related]  

  • 9. Delayed cardiac perforation by one small body diameter defibrillator lead.
    Haghjoo M; Alizadeh A; Fazelifar AF; Hajahmadi M; Sadr-Ameli MA
    J Electrocardiol; 2010; 43(1):71-3. PubMed ID: 19520384
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Management of subacute and delayed right ventricular perforation with a pacing or an implantable cardioverter-defibrillator lead.
    Laborderie J; Barandon L; Ploux S; Deplagne A; Mokrani B; Reuter S; Le Gal F; Jais P; Haissaguerre M; Clementy J; Bordachar P
    Am J Cardiol; 2008 Nov; 102(10):1352-5. PubMed ID: 18993154
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biventricular implantable cardioverter defibrillator right ventricle pace-sense ring electrode failure: lead switch fix.
    Venkataraman G; Moore H; Karasik P; Singh S; Fletcher R
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):899-903. PubMed ID: 18684289
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Perforation of the right ventricular free wall by an ICD lead in a patient with isolated noncompaction of the ventricular myocardium.
    Sakai Y; Sato Y; Matsuo S; Imai S; Kunimasa T; Matsumoto N; Saito S
    Int J Cardiol; 2007 May; 117(3):e104-6. PubMed ID: 17350119
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Delayed pericarditis associated with an implantable cardioverter defibrillator implantation using an active-fixation atrial lead.
    Kono K; Todoroki M; Karasawa T; Ito I; Tadokoro K; Shinbo G; Horinaka S; Matsuoka H; Mochizuki Y
    Pacing Clin Electrophysiol; 2008 May; 31(5):621-3. PubMed ID: 18439181
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Successful management of a late right ventricular and diaphragmatic perforation by a defibrillator lead.
    Fuenmayor A AJ; Rodríguez S YA
    Europace; 2014 Jun; 16(6):886. PubMed ID: 24008496
    [No Abstract]   [Full Text] [Related]  

  • 15. Lead fracture and free-wall perforation in a patient with an implantable cardioverter-defibrillator.
    Kwon O; Kang SH; Park HW; Choi SW; Kim SH; Kim KH; Jin ES; Nam GB
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e167-9. PubMed ID: 21070262
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Perforation of the right ventricular free wall by an active fixation transvenous cardioverter defibrillator lead.
    Shohat-Zabarski R; Kusniec J; Strasberg B
    Pacing Clin Electrophysiol; 1999 Jul; 22(7):1118-9. PubMed ID: 10456650
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inadequate ICD discharges due to diaphragmatic electromyopotential oversensing as the first sign of right ventricular lead perforation.
    Wiegand UK; Wilke I; Bonnemeier H; Eberhardt F; Bode F
    Pacing Clin Electrophysiol; 2006 Oct; 29(10):1176-8. PubMed ID: 17038150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Asymptomatic anterior perforation of an ICD lead into subcutaneous tissues.
    Fisher JD; Fox M; Kim SG; Goldstein D; Haramati LB
    Pacing Clin Electrophysiol; 2008 Jan; 31(1):7-9. PubMed ID: 18181901
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Delayed defibrillator lead perforation.
    Park RE; Melton IC; Crozier IG
    Pacing Clin Electrophysiol; 2008 Jun; 31(6):785-6. PubMed ID: 18507559
    [No Abstract]   [Full Text] [Related]  

  • 20. Inadvertent transarterial insertion of atrial and ventricular defibrillator leads.
    Issa ZF; Rumman SS; Mullin JC
    J Interv Card Electrophysiol; 2009 Jan; 24(1):63-6. PubMed ID: 19016315
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.