These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

313 related articles for article (PubMed ID: 18990649)

  • 41. Motor control over the phantom limb in above-elbow amputees and its relationship with phantom limb pain.
    Gagné M; Reilly KT; Hétu S; Mercier C
    Neuroscience; 2009 Aug; 162(1):78-86. PubMed ID: 19406214
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Myoelectric control of a computer animated hand: a new concept based on the combined use of a tree-structured artificial neural network and a data glove.
    Sebelius F; Eriksson L; Balkenius C; Laurell T
    J Med Eng Technol; 2006; 30(1):2-10. PubMed ID: 16393847
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Neural control of motor prostheses.
    Scherberger H
    Curr Opin Neurobiol; 2009 Dec; 19(6):629-33. PubMed ID: 19896364
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The SmartHand transradial prosthesis.
    Cipriani C; Controzzi M; Carrozza MC
    J Neuroeng Rehabil; 2011 May; 8():29. PubMed ID: 21600048
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Development of a system for finding best electrode position for myoelectric hand control for derating of upper limb amputee.
    Konishi Y; Mizobata Y; Yoshida M
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5700-3. PubMed ID: 18003306
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Motor-commands decoding using peripheral nerve signals: a review.
    Hong KS; Aziz N; Ghafoor U
    J Neural Eng; 2018 Jun; 15(3):031004. PubMed ID: 29498358
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A novel concept for a prosthetic hand with a bidirectional interface: a feasibility study.
    Cipriani C; Antfolk C; Balkenius C; Rosén B; Lundborg G; Carrozza MC; Sebelius F
    IEEE Trans Biomed Eng; 2009 Nov; 56(11 Pt 2):2739-43. PubMed ID: 19758852
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Bio-inspired sensorization of a biomechatronic robot hand for the grasp-and-lift task.
    Edin BB; Ascari L; Beccai L; Roccella S; Cabibihan JJ; Carrozza MC
    Brain Res Bull; 2008 Apr; 75(6):785-95. PubMed ID: 18394525
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces.
    Micera S; Rossini PM; Rigosa J; Citi L; Carpaneto J; Raspopovic S; Tombini M; Cipriani C; Assenza G; Carrozza MC; Hoffmann KP; Yoshida K; Navarro X; Dario P
    J Neuroeng Rehabil; 2011 Sep; 8():53. PubMed ID: 21892926
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Neural interfaces for control of upper limb prostheses: the state of the art and future possibilities.
    Schultz AE; Kuiken TA
    PM R; 2011 Jan; 3(1):55-67. PubMed ID: 21257135
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Hand-in-hand advances in biomedical engineering and sensorimotor restoration.
    Pisotta I; Perruchoud D; Ionta S
    J Neurosci Methods; 2015 May; 246():22-9. PubMed ID: 25769276
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Action potential classification with dual channel intrafascicular electrodes.
    McNaughton TG; Horch KW
    IEEE Trans Biomed Eng; 1994 Jul; 41(7):609-16. PubMed ID: 7927381
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A bioelectric neural interface towards intuitive prosthetic control for amputees.
    Nguyen AT; Xu J; Jiang M; Luu DK; Wu T; Tam WK; Zhao W; Drealan MW; Overstreet CK; Zhao Q; Cheng J; Keefer EW; Yang Z
    J Neural Eng; 2020 Nov; 17(6):. PubMed ID: 33091891
    [No Abstract]   [Full Text] [Related]  

  • 54. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.
    Tan DW; Schiefer MA; Keith MW; Anderson JR; Tyler DJ
    J Neural Eng; 2015 Apr; 12(2):026002. PubMed ID: 25627310
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Preliminary results on the design of a tool for inserting of transverse intrafascicular multichannel electrodes (TIME) into the peripheral nervous system.
    Ghionzoli A; Genovese V; Bossi S; Stefanini C; Micera S
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():7634-8. PubMed ID: 22256106
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Biomimetic finger control by filtering of distributed forelimb pressures.
    Curcie DJ; Flint JA; Craelius W
    IEEE Trans Neural Syst Rehabil Eng; 2001 Mar; 9(1):69-75. PubMed ID: 11482365
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Prosthetic devices: challenges and implications of robotic implants and biological interfaces.
    Lai JC; Schoen MP; Perez Gracia A; Naidu DS; Leung SW
    Proc Inst Mech Eng H; 2007 Feb; 221(2):173-83. PubMed ID: 17385571
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Evaluation of a graphic interface to control a robotic grasping arm: a multicenter study.
    Laffont I; Biard N; Chalubert G; Delahoche L; Marhic B; Boyer FC; Leroux C
    Arch Phys Med Rehabil; 2009 Oct; 90(10):1740-8. PubMed ID: 19801065
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
    Hochberg LR; Serruya MD; Friehs GM; Mukand JA; Saleh M; Caplan AH; Branner A; Chen D; Penn RD; Donoghue JP
    Nature; 2006 Jul; 442(7099):164-71. PubMed ID: 16838014
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees.
    Vu PP; Vaskov AK; Irwin ZT; Henning PT; Lueders DR; Laidlaw AT; Davis AJ; Nu CS; Gates DH; Gillespie RB; Kemp SWP; Kung TA; Chestek CA; Cederna PS
    Sci Transl Med; 2020 Mar; 12(533):. PubMed ID: 32132217
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.