These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
200 related articles for article (PubMed ID: 19012530)
1. Electrochemical detection of blood alcohol concentration using a disposable biosensor based on screen-printed electrode modified with Nafion and gold nanoparticles. Luo P; Xie G; Liu Y; Xu H; Deng S; Song F Clin Chem Lab Med; 2008; 46(11):1641-7. PubMed ID: 19012530 [TBL] [Abstract][Full Text] [Related]
2. Determination of serum alcohol using a disposable biosensor. Luo P; Liu Y; Xie G; Xiong X; Deng S; Song F Forensic Sci Int; 2008 Aug; 179(2-3):192-8. PubMed ID: 18653295 [TBL] [Abstract][Full Text] [Related]
3. One-step fabrication of integrated disposable biosensor based on ADH/NAD+/meldola's blue/graphitized mesoporous carbons/chitosan nanobiocomposite for ethanol detection. Hua E; Wang L; Jing X; Chen C; Xie G Talanta; 2013 Jul; 111():163-9. PubMed ID: 23622540 [TBL] [Abstract][Full Text] [Related]
4. A novel microassay for measuring blood alcohol concentration using a disposable biosensor strip. Zhen S; Wang Y; Liu C; Xie G; Zou C; Zheng J; Zhu Y Forensic Sci Int; 2011 Apr; 207(1-3):177-82. PubMed ID: 21035284 [TBL] [Abstract][Full Text] [Related]
5. A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose. Piano M; Serban S; Biddle N; Pittson R; Drago GA; Hart JP Anal Biochem; 2010 Jan; 396(2):269-74. PubMed ID: 19766585 [TBL] [Abstract][Full Text] [Related]
6. Electrocatalytic oxidation of NADH at gold nanoparticles loaded poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonic acid) film modified electrode and integration of alcohol dehydrogenase for alcohol sensing. Manesh KM; Santhosh P; Gopalan A; Lee KP Talanta; 2008 Jun; 75(5):1307-14. PubMed ID: 18585217 [TBL] [Abstract][Full Text] [Related]
7. Toluidine blue adsorbed on alcohol dehydrogenase modified glassy carbon electrode for voltammetric determination of ethanol. Periasamy AP; Umasankar Y; Chen SM Talanta; 2011 Jan; 83(3):930-6. PubMed ID: 21147339 [TBL] [Abstract][Full Text] [Related]
8. Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+. Piano M; Serban S; Pittson R; Drago GA; Hart JP Talanta; 2010 Jun; 82(1):34-7. PubMed ID: 20685431 [TBL] [Abstract][Full Text] [Related]
9. Enzyme biosensor based on the immobilization of HRP on SiO₂/BSA/Au composite nanoparticles. Yuan S; Yuan R; Chai Y; Zhuo Y; Yang X; Yuan Y Appl Biochem Biotechnol; 2010 Dec; 162(8):2189-96. PubMed ID: 20532672 [TBL] [Abstract][Full Text] [Related]
10. Highly sensitive amperometric biosensor for determination of NADH and ethanol based on Au-Ag nanoparticles/poly(L-Cysteine)/reduced graphene oxide nanocomposite. Aydoğdu Tığ G Talanta; 2017 Dec; 175():382-389. PubMed ID: 28842007 [TBL] [Abstract][Full Text] [Related]
11. Highly sensitive glucose biosensor based on the effective immobilization of glucose oxidase/carbon-nanotube and gold nanoparticle in nafion film and peroxyoxalate chemiluminescence reaction of a new fluorophore. Zargoosh K; Chaichi MJ; Shamsipur M; Hossienkhani S; Asghari S; Qandalee M Talanta; 2012 May; 93():37-43. PubMed ID: 22483873 [TBL] [Abstract][Full Text] [Related]
12. Urea biosensor based on PANi(urease)-Nafion/Au composite electrode. Luo YC; Do JS Biosens Bioelectron; 2004 Jul; 20(1):15-23. PubMed ID: 15142572 [TBL] [Abstract][Full Text] [Related]
13. A novel reagentless amperometric immunosensor based on gold nanoparticles/TMB/Nafion-modified electrode. Wu Y; Zheng J; Li Z; Zhao Y; Zhang Y Biosens Bioelectron; 2009 Jan; 24(5):1389-93. PubMed ID: 18799302 [TBL] [Abstract][Full Text] [Related]
14. Comparison of amperometric biosensors fabricated by palladium sputtering, palladium electrodeposition and Nafion/carbon nanotube casting on screen-printed carbon electrodes. Lee CH; Wang SC; Yuan CJ; Wen MF; Chang KS Biosens Bioelectron; 2007 Jan; 22(6):877-84. PubMed ID: 16644200 [TBL] [Abstract][Full Text] [Related]
15. An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode. Chauhan N; Narang J; Meena ; Pundir CS Int J Biol Macromol; 2012 Dec; 51(5):879-86. PubMed ID: 22922113 [TBL] [Abstract][Full Text] [Related]
16. Amperometric determination of total phenolic content in wine by laccase immobilized onto silver nanoparticles/zinc oxide nanoparticles modified gold electrode. Chawla S; Rawal R; Kumar D; Pundir CS Anal Biochem; 2012 Nov; 430(1):16-23. PubMed ID: 22863983 [TBL] [Abstract][Full Text] [Related]
17. A novel, disposable, screen-printed amperometric biosensor for ketone 3-β-hydroxybutyrate fabricated using a 3-β-hydroxybutyrate dehydrogenase-mesoporous silica conjugate. Shimomura T; Sumiya T; Ono M; Ito T; Hanaoka TA Anal Bioanal Chem; 2013 Jan; 405(1):297-305. PubMed ID: 23096941 [TBL] [Abstract][Full Text] [Related]
19. A facile and practical biosensor for choline based on manganese dioxide nanoparticles synthesized in-situ at the surface of electrode by one-step electrodeposition. Yu G; Zhao Q; Wu W; Wei X; Lu Q Talanta; 2016 Jan; 146():707-13. PubMed ID: 26695320 [TBL] [Abstract][Full Text] [Related]