These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 19021157)

  • 1. Theory of ion transport in electrochemically switchable nanoporous metallized membranes.
    Amatore C; Oleinick AI; Svir I
    Chemphyschem; 2009 Jan; 10(1):211-21. PubMed ID: 19021157
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements of transient membrane potential after current switch-off as a tool to study the electrochemical properties of supported thin nanoporous layers.
    Yaroshchuk A; Karpenko L; Ribitsch V
    J Phys Chem B; 2005 Apr; 109(16):7834-42. PubMed ID: 16851912
    [TBL] [Abstract][Full Text] [Related]  

  • 3. How the asymmetry of internal potential influences the shape of I-V characteristic of nanochannels.
    Kosińska ID
    J Chem Phys; 2006 Jun; 124(24):244707. PubMed ID: 16821996
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ion-rejection, electrokinetic and electrochemical properties of a nanoporous track-etched membrane and their interpretation by means of space charge model.
    Yaroshchuk A; Boiko Y; Makovetskiy A
    Langmuir; 2009 Aug; 25(16):9605-14. PubMed ID: 19585984
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ion current rectification at nanopores in glass membranes.
    White HS; Bund A
    Langmuir; 2008 Mar; 24(5):2212-8. PubMed ID: 18225931
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Theoretical description of the ion transport across nanopores with titratable fixed charges: analogies between ion channels and synthetic pores.
    Ramírez P; Aguilella-Arzo M; Alcaraz A; Cervera J; Aguilella VM
    Cell Biochem Biophys; 2006; 44(2):287-312. PubMed ID: 16456229
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Molecular sieving and sensing with gold nanotube membranes.
    Wirtz M; Parker M; Kobayashi Y; Martin CR
    Chem Rec; 2002; 2(4):259-67. PubMed ID: 12203908
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling ion transport in tethered bilayer lipid membranes. 1. Passive ion permeation.
    Robertson JW; Friedrich MG; Kibrom A; Knoll W; Naumann RL; Walz D
    J Phys Chem B; 2008 Aug; 112(34):10475-82. PubMed ID: 18680332
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Theoretical and experimental analysis of conductivity, ion diffusion and molecular transport during cell electroporation--relation between short-lived and long-lived pores.
    Pavlin M; Miklavcic D
    Bioelectrochemistry; 2008 Nov; 74(1):38-46. PubMed ID: 18499534
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intrinsic ion selectivity of narrow hydrophobic pores.
    Song C; Corry B
    J Phys Chem B; 2009 May; 113(21):7642-9. PubMed ID: 19419185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modifying the liquid/liquid interface: pores, particles and deposition.
    Dryfe RA
    Phys Chem Chem Phys; 2006 Apr; 8(16):1869-83. PubMed ID: 16633673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metal nanotubule membranes with electrochemically switchable ion-transport selectivity.
    Nishizawa M; Menon VP; Martin CR
    Science; 1995 May; 268(5211):700-2. PubMed ID: 17832383
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of crown ether on ion currents through synthetic membranes containing a single conically shaped nanopore.
    Heins EA; Baker LA; Siwy ZS; Mota MO; Martin CR
    J Phys Chem B; 2005 Oct; 109(39):18400-7. PubMed ID: 16853369
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface-charge induced ion depletion and sample stacking near single nanopores in microfluidic devices.
    Zhou K; Kovarik ML; Jacobson SC
    J Am Chem Soc; 2008 Jul; 130(27):8614-6. PubMed ID: 18549214
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabrication of sub-20 nm nanopore arrays in membranes with embedded metal electrodes at wafer scales.
    Bai J; Wang D; Nam SW; Peng H; Bruce R; Gignac L; Brink M; Kratschmer E; Rossnagel S; Waggoner P; Reuter K; Wang C; Astier Y; Balagurusamy V; Luan B; Kwark Y; Joseph E; Guillorn M; Polonsky S; Royyuru A; Papa Rao S; Stolovitzky G
    Nanoscale; 2014 Aug; 6(15):8900-6. PubMed ID: 24964839
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of nanopores as candidates for electronic analyte detection.
    Nakane J; Akeson M; Marziali A
    Electrophoresis; 2002 Aug; 23(16):2592-601. PubMed ID: 12210162
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Some properties of electrolyte solutions in nanoconfinement revealed by the measurement of transient filtration potential after pressure switch off.
    Yaroshchuk AE; Boiko YP; Makovetskiy AL
    Langmuir; 2005 Aug; 21(17):7680-90. PubMed ID: 16089369
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Effectiveness of energy transformation during active transport of ions in a biomembrane].
    Melkikh AV; Seleznev VD
    Biofizika; 1994; 39(2):337-44. PubMed ID: 8193196
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Requirements on models and models of active transport of ions in biomembranes.
    Melkikh AV; Seleznev VD
    Bull Math Biol; 2006 Feb; 68(2):385-99. PubMed ID: 16794936
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hydraulic permeability of hollow-fiber membranes.
    Stevenson JF; Parry JS; Gupta KM
    J Biomed Mater Res; 1978 May; 12(3):401-19. PubMed ID: 670261
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.