These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
275 related articles for article (PubMed ID: 19026622)
1. Interference of hemoglobinA1c (HbA1c) detection using ion-exchange high performance liquid chromatography (HPLC) method by clinically silent hemoglobin variant in University Malaya Medical Centre (UMMC)--a case report. Thevarajah M; Nadzimah MN; Chew YY Clin Biochem; 2009 Mar; 42(4-5):430-4. PubMed ID: 19026622 [TBL] [Abstract][Full Text] [Related]
2. Advantage of HbA1c assay by HPLC D-10 versus cobas integra 400 in a population carrier for HbS and HbC. Bouzid K; Bahlous A; Ferjani W; Kalai E; Ducrocq R; Ben Mami F; Abdelmoula J Clin Lab; 2012; 58(7-8):821-8. PubMed ID: 22997985 [TBL] [Abstract][Full Text] [Related]
3. Determination of glycated hemoglobin in clinically silent hemoglobin variants. Schnedl WJ; Lahousen T; Lang T; Lipp RW; Yonehara S; Fukunaga S; Imai T; Little RR Diabetes Metab Res Rev; 2004; 20(6):460-5. PubMed ID: 15386816 [TBL] [Abstract][Full Text] [Related]
4. Effects of hemoglobin C, D, E and S traits on measurements of hemoglobin A1c by twelve methods. Rohlfing C; Hanson S; Weykamp C; Siebelder C; Higgins T; Molinaro R; Yip PM; Little RR Clin Chim Acta; 2016 Apr; 455():80-3. PubMed ID: 26828530 [TBL] [Abstract][Full Text] [Related]
5. Effects of hemoglobin variants HbJ Bangkok, HbE, HbG Taipei, and HbH on analysis of glycated hemoglobin via ion-exchange high-performance liquid chromatography. Zhang XM; Wen DM; Xu SN; Suo MH; Chen YQ J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28407371 [TBL] [Abstract][Full Text] [Related]
6. Degree of discrepancy between HbA1c and glycemia in variant hemoglobin is smaller when HbA1c is measured by new-type Arkray HPLC compared with old-type HPLC. Koga M; Kurebayashi S; Murai J; Saito H; Miyazaki A Clin Biochem; 2014 Jan; 47(1-2):123-5. PubMed ID: 24128409 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of conditions associated with glycated hemoglobin values below the reference range. Schnedl WJ; Lahousen T; Krause R; Wallner SJ; Piswanger-Soelkner C; Lipp RW Clin Lab; 2007; 53(3-4):179-81. PubMed ID: 17447655 [TBL] [Abstract][Full Text] [Related]
8. Common hemoglobin variants in southern Taiwan and their effect on the determination of HbA1c by ion-exchange high-performance liquid chromatography. Chu CH; Lam HC; Lee JK; Wang MC; Lu CC; Sun CC; Chuang MJ J Chin Med Assoc; 2009 Jul; 72(7):362-7. PubMed ID: 19581142 [TBL] [Abstract][Full Text] [Related]
9. An incidental finding of a hemoglobin E variant in a diabetic patient with an abnormal glycated hemoglobin level: a case report. Karki R; Lamichhane S; Jha R; Manandhar R J Med Case Rep; 2024 Jun; 18(1):279. PubMed ID: 38877536 [TBL] [Abstract][Full Text] [Related]
10. Hemoglobin Seville [α2 β2 81(EF5) Leu→Phe] a silent phenotypic variant that interferes in hemoglobin A1c measurement by ion-exchange HPLC method. del Rey TH; Conde-Sánchez M; Ropero-Gradilla P; Domínguez-Pascual I; González-Fernández FA; Villegas A; Guerrero JM Clin Biochem; 2011 Jul; 44(10-11):933-5. PubMed ID: 21554865 [TBL] [Abstract][Full Text] [Related]
11. Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography. Herb T; Taylor AS; Li SH; Manthei DM; Gherasim C Lab Med; 2024 Jul; 55(4):528-533. PubMed ID: 38253465 [TBL] [Abstract][Full Text] [Related]
12. Silent hemoglobin variants and determination of HbA(1c) with the high-resolution program of the HPLC HA-8160 hemoglobin analyzer. Schnedl WJ; Lahousen T; Wallner SJ; Krause R; Lipp RW Clin Biochem; 2005 Jan; 38(1):88-91. PubMed ID: 15607323 [TBL] [Abstract][Full Text] [Related]
13. Effect of HbE and HbH on HbA1C level by ionic exchange HPLC comparing to immunoturbidimetry. Pravatmuang P; Sae-Ngow B; Whanpuch T; Leowattana W Clin Chim Acta; 2001 Nov; 313(1-2):171-8. PubMed ID: 11694256 [TBL] [Abstract][Full Text] [Related]
14. [Influence and analysis of seven kinds of hemoglobin variants on HbA1c detection]. Chen Y; Hu Y; Hao Y; Chi S; Zhao F; Zhang H; Li W; Dou Y Zhonghua Yi Xue Za Zhi; 2014 Feb; 94(6):438-41. PubMed ID: 24754988 [TBL] [Abstract][Full Text] [Related]
15. Falsely high HbA Xu A; Lei J; Li J; Chen W; Zhou Y; Zheng R; Ji L Scand J Clin Lab Invest; 2018; 78(7-8):621-625. PubMed ID: 30375897 [TBL] [Abstract][Full Text] [Related]
16. Erroneous HbA1c results in a patient with elevated HbC and HbF. Adekanmbi J; Higgins T; Rodriguez-Capote K; Thomas D; Winterstein J; Dixon T; Gifford JL; Krause R; Venner AA; Clarke G; Estey MP Clin Chim Acta; 2016 Nov; 462():153-157. PubMed ID: 27664335 [TBL] [Abstract][Full Text] [Related]
17. Performance evaluation of ion exchange and affinity chromatography for HbA1c estimation in diabetic patients with HbD: a study of 129 samples. Moiz B; Hashmi MR; Sadaf S Clin Biochem; 2008 Oct; 41(14-15):1204-10. PubMed ID: 18644359 [TBL] [Abstract][Full Text] [Related]
18. Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method. Chen D; Crimmins DL; Hsu FF; Lindberg FP; Scott MG Clin Chem; 1998 Jun; 44(6 Pt 1):1296-301. PubMed ID: 9625056 [TBL] [Abstract][Full Text] [Related]
19. Hemoglobin Sherwood Forest detected by high performance liquid chromatography for hemoglobin A1c. Schnedl WJ; Reisinger EC; Pieber TR; Lipp RW; Schreiber F; Hopmeier P; Krejs GJ Am J Clin Pathol; 1995 Oct; 104(4):444-6. PubMed ID: 7572795 [TBL] [Abstract][Full Text] [Related]
20. Two novel haemoglobin variants that affect haemoglobin A1c measurement by ion-exchange chromatography. Bots M; Stroobants AK; Delzenne B; Soeters MR; de Vries JE; Weykamp CW; Norg RJ; Veldthuis M; Zwieten Rv Clin Chem Lab Med; 2015 Aug; 53(9):1465-71. PubMed ID: 26035110 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]