BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

806 related articles for article (PubMed ID: 19029600)

  • 1. Ti-TiC-TiC/DLC gradient nano-composite film on a biomedical NiTi alloy.
    Zheng Y; Liu D; Liu X; Li L
    Biomed Mater; 2008 Dec; 3(4):044103. PubMed ID: 19029600
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The wear properties and adhesion strength of the diamond-like carbon film coated on SUS, Ti and Ni-Ti with plasma pre-treatment.
    Ozeki K; Masuzawa T; Hirakuri KK
    Biomed Mater Eng; 2010; 20(1):21-35. PubMed ID: 20448301
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wear-corrosion performance of Si-DLC coatings on Ti-6Al-4V substrate.
    Kim JG; Lee KR; Yang SJ
    J Biomed Mater Res A; 2008 Jul; 86(1):41-7. PubMed ID: 17941020
    [TBL] [Abstract][Full Text] [Related]  

  • 6. NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.
    Yahia LH; Lombardi S; Piron D; Klemberg-Sapieha JE; Wertheimer MR
    Med Prog Technol; 1996-1997; 21(4):187-93. PubMed ID: 9110276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. PIIID-formed (Ti, O)/Ti, (Ti, N)/Ti and (Ti, O, N)/Ti coatings on NiTi shape memory alloy for medical applications.
    Sun T; Wang LP; Wang M; Tong HW; Lu WW
    Mater Sci Eng C Mater Biol Appl; 2012 Aug; 32(6):1469-79. PubMed ID: 24364947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design, characterization and testing of Ti-based multicomponent coatings for load-bearing medical applications.
    Shtansky DV; Gloushankova NA; Sheveiko AN; Kharitonova MA; Moizhess TG; Levashov EA; Rossi F
    Biomaterials; 2005 Jun; 26(16):2909-24. PubMed ID: 15603786
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
    Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
    Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro cytocompatibility studies of Diamond Like Carbon coatings on titanium.
    Kumari TV; Anil Kumar PR; Muraleedharan CV; Bhuvaneshwar GS; Sampeur Y; Derangere F; Suryanarayanan R
    Biomed Mater Eng; 2002; 12(4):329-38. PubMed ID: 12652027
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nanostructured titanium/diamond-like carbon multilayer films: deposition, characterization, and applications.
    Dwivedi N; Kumar S; Malik HK
    ACS Appl Mater Interfaces; 2011 Nov; 3(11):4268-78. PubMed ID: 21942626
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study on hemocompatibility and corrosion behavior of ion implanted TiNi shape memory alloy and Co-based alloys.
    Liang C; Huang N
    J Biomed Mater Res A; 2007 Oct; 83(1):235-40. PubMed ID: 17607737
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fabrication and characteristics of bioactive sodium titanate/titania graded film on NiTi shape memory alloy.
    Chu CL; Chung CY; Zhou J; Pu YP; Lin PH
    J Biomed Mater Res A; 2005 Dec; 75(3):595-602. PubMed ID: 16106440
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrochemical corrosion of titanium and titanium-based alloys.
    Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT
    J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multifunctional Ti-(Ca,Zr)-(C,N,O,P) films for load-bearing implants.
    Shtansky DV; Gloushankova NA; Bashkova IA; Kharitonova MA; Moizhess TG; Sheveiko AN; Kiryukhantsev-Korneev FV; Petrzhik MI; Levashov EA
    Biomaterials; 2006 Jul; 27(19):3519-31. PubMed ID: 16530825
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characteristics and mechanical properties of titanium-containing diamond like carbon films deposited by cathodic arc evaporation.
    Tsai PC; Chiang JY; Hwang YF
    J Nanosci Nanotechnol; 2008 May; 8(5):2516-21. PubMed ID: 18572676
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemocompatibility of nitrogen-doped, hydrogen-free diamond-like carbon prepared by nitrogen plasma immersion ion implantation-deposition.
    Kwok SC; Yang P; Wang J; Liu X; Chu PK
    J Biomed Mater Res A; 2004 Jul; 70(1):107-14. PubMed ID: 15174114
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone.
    Wang H; Xu M; Zhang W; Kwok DT; Jiang J; Wu Z; Chu PK
    Biomaterials; 2010 Nov; 31(32):8181-7. PubMed ID: 20692699
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.