These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 19037982)

  • 1. Doppler echocardiographic assessment of pulmonary prostheses: a comprehensive assessment including velocity time integral ratio and prosthesis effective orifice area.
    Sadeghpour A; Saadatifar H; Kiavar M; Esmaeilzadeh M; Maleki M; Ojaghi Z; Noohi F; Samiei N; Mohebbi A
    Congenit Heart Dis; 2008; 3(6):415-21. PubMed ID: 19037982
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comprehensive hemodynamic assessment of 368 normal St. Jude Medical mechanical mitral valve prostheses based on early postimplantation echocardiographic studies.
    Blauwet LA; Malouf JF; Connolly HM; Hodge DO; Herges RM; Suri RM; Miller FA
    J Am Soc Echocardiogr; 2013 Apr; 26(4):381-9. PubMed ID: 23484437
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comprehensive echocardiographic assessment of mechanical tricuspid valve prostheses based on early post-implantation echocardiographic studies.
    Blauwet LA; Burkhart HM; Dearani JA; Malouf JF; Connolly HM; Hodge DO; Herges RM; Miller FA
    J Am Soc Echocardiogr; 2011 Apr; 24(4):414-24. PubMed ID: 21244867
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Doppler hemodynamics of 51 clinically and echocardiographically normal pulmonary valve prostheses.
    Novaro GM; Connolly HM; Miller FA
    Mayo Clin Proc; 2001 Feb; 76(2):155-60. PubMed ID: 11213303
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of normal hemodynamic profile of mechanical pulmonary prosthesis by doppler echocardiography: a prospective cross-sectional study.
    Shojaeifard M; Daryanavard A; Karimi Behnagh A; Moradian M; Erami S; Dehghani Mohammad Abadi H
    Cardiovasc Ultrasound; 2020 May; 18(1):14. PubMed ID: 32414369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Doppler echocardiography of 79 normal CarboMedics mitral prostheses: a comprehensive assessment including time-velocity integral ratio and prosthesis performance index.
    Blauwet LA; Malouf JF; Connolly HM; Hodge DO; Herges RM; Sundt TM; Miller FA
    J Am Soc Echocardiogr; 2007 Oct; 20(10):1125-30. PubMed ID: 17588713
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comprehensive hemodynamic assessment of 305 normal CarboMedics mitral valve prostheses based on early postimplantation echocardiographic studies.
    Blauwet LA; Malouf JF; Connolly HM; Hodge DO; Herges RM; Sundt TM; Miller FA
    J Am Soc Echocardiogr; 2012 Feb; 25(2):173-81. PubMed ID: 22133689
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comprehensive echocardiographic assessment of normal mitral Medtronic Hancock II, Medtronic Mosaic, and Carpentier-Edwards Perimount bioprostheses early after implantation.
    Blauwet LA; Malouf JF; Connolly HM; Hodge DO; Evans KN; Herges RM; Sundt TM; Miller FA
    J Am Soc Echocardiogr; 2010 Jun; 23(6):656-66. PubMed ID: 20497863
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement.
    Shahanavaz S; Asnes JD; Grohmann J; Qureshi AM; Rome JJ; Tanase D; Crystal MA; Latson LA; Morray BH; Hellenbrand W; Balzer DT; Gewillig M; Love JC; Berdjis F; Gillespie MJ; McElhinney DB
    Circ Cardiovasc Interv; 2018 Aug; 11(8):e006453. PubMed ID: 30354783
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemodynamic performance evaluation of small aortic ATS Medical valves by Doppler echocardiography.
    Kirzner CF; Vinals B; Moya J; Puente JG; Rabago R; Artiz V; Martinelli J; Fraile-Chief J
    J Heart Valve Dis; 1997 Nov; 6(6):661-5. PubMed ID: 9427139
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Doppler echocardiography of 119 normal-functioning St Jude Medical mitral valve prostheses: a comprehensive assessment including time-velocity integral ratio and prosthesis performance index.
    Malouf JF; Ballo M; Connolly HM; Hodge DO; Herges RM; Mullany CJ; Miller FA
    J Am Soc Echocardiogr; 2005 Mar; 18(3):252-6. PubMed ID: 15746715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Midterm evaluation of biological prosthetic valves in the pulmonary position of grown-up patients.
    Vohra HA; Whistance RN; Baliulis G; Janusauskas V; Kaarne M; Veldtman GR; Roman K; Vettukattil JJ; Gnanapragasam J; Salmon AP; Haw MP
    Thorac Cardiovasc Surg; 2012 Apr; 60(3):205-9. PubMed ID: 22411751
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Single-center comparative outcomes of the Edwards SAPIEN and Medtronic Melody transcatheter heart valves in the pulmonary position.
    Faza N; Kenny D; Kavinsky C; Amin Z; Heitschmidt M; Hijazi ZM
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E535-41. PubMed ID: 23008193
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationship Between Pulmonary Venous Flow and Prosthetic Mitral Valve Thrombosis.
    Cerşit S; Gündüz S; Ozan Gürsoy M; Karakoyun S; Kalçık M; Bayam E; Yesin M; Özkan M
    J Heart Valve Dis; 2018 Jan; 27(1):65-70. PubMed ID: 30560601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemodynamic performance of mitroflow aortic pericardial bioprosthesis - optimizing management for the small aortic annulus.
    Jamieson WR; Forgie WR; Hayden RI; Langlois Y; Ling H; Stanford EA; Roberts KA; Dolman WB
    Thorac Cardiovasc Surg; 2010 Mar; 58(2):69-75. PubMed ID: 20333567
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Melody valve implant within failed bioprosthetic valves in the pulmonary position: a multicenter experience.
    Gillespie MJ; Rome JJ; Levi DS; Williams RJ; Rhodes JF; Cheatham JP; Hellenbrand WE; Jones TK; Vincent JA; Zahn EM; McElhinney DB
    Circ Cardiovasc Interv; 2012 Dec; 5(6):862-70. PubMed ID: 23212395
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Echocardiographic assessment of prosthetic mitral valves in children.
    Hayashi T; Inuzuka R; Ono H; Kato H
    Echocardiography; 2017 Jan; 34(1):94-101. PubMed ID: 27804157
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.
    Evin M; Guivier-Curien C; Pibarot P; Kadem L; Rieu R
    Artif Organs; 2016 May; 40(5):E52-60. PubMed ID: 26813110
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Limitations of Doppler echocardiography in the assessment of prosthetic valve hemodynamics.
    Henneke KH; Pongratz G; Bachmann K
    J Heart Valve Dis; 1995 Jan; 4(1):18-25. PubMed ID: 7742982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis.
    Mykén PS; Berggren HE; Larsson S; Roberts B; Wallentin I; Caidahl K
    J Thorac Cardiovasc Surg; 1998 Oct; 116(4):599-608. PubMed ID: 9766588
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.