These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

878 related articles for article (PubMed ID: 19038475)

  • 1. Study on CAD&RP for removable complete denture.
    Sun Y; Lü P; Wang Y
    Comput Methods Programs Biomed; 2009 Mar; 93(3):266-72. PubMed ID: 19038475
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Research and development of computer aided design and rapid prototyping technology for complete denture].
    Sun YC; Lü PJ; Wang Y; Han JY; Zhao JJ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 Jun; 42(6):324-9. PubMed ID: 17888244
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures.
    Maeda Y; Minoura M; Tsutsumi S; Okada M; Nokubi T
    Int J Prosthodont; 1994; 7(1):17-21. PubMed ID: 8179777
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The study of a computer aided artificial teeth arrangement of complete denture].
    Cheng X; Hua X; Hua Z
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2000 Mar; 35(2):147-9. PubMed ID: 11780490
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Computer aided design and manufacture of the removable partial denture framework].
    Yang L; Cheng X; Dai N; Zhu S; Yan G; Gao Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Feb; 27(1):170-3. PubMed ID: 20337047
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Computer aided design and computer aided manufacture of sacrificial pattern of removable partial denture framework].
    Wu L; Lü PJ; Wang Y; Ai HJ; Dong DY
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2006 Jul; 41(7):432-5. PubMed ID: 17067464
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A preliminary report of designing removable partial denture frameworks using a specifically developed software package.
    Han J; Wang Y; Lü P
    Int J Prosthodont; 2010; 23(4):370-5. PubMed ID: 20617229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Development and applications of a computer aided complete denture design system].
    Hua X; Cheng X
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2001 Aug; 19(4):235-6. PubMed ID: 12539729
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Establishment of artificial-tooth three-dimensional coordinates based on dental anatomic concepts].
    Wang Y; Liu ML; Huo P; Lü PJ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2006 Nov; 41(11):684-6. PubMed ID: 17331367
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Methodology of computer-aided design of automatic artificial tooth selection for complete denture].
    Wang YG; Lv PJ; Wang Y; Sun YC; Zhao YJ
    Beijing Da Xue Xue Bao Yi Xue Ban; 2010 Feb; 42(1):108-10. PubMed ID: 20140056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Computer design of artificial tooth series of complete removable prostheses].
    Riakhovskiĭ AN; Poliakova MV
    Stomatologiia (Mosk); 2011; 90(2):65-70. PubMed ID: 21512470
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data.
    Goodacre CJ; Garbacea A; Naylor WP; Daher T; Marchack CB; Lowry J
    J Prosthet Dent; 2012 Jan; 107(1):34-46. PubMed ID: 22230914
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new optical 3D-scanning system for CAD/CAM technology.
    Mehl A; Hickel R
    Int J Comput Dent; 1999 Apr; 2(2):129-36. PubMed ID: 11351491
    [No Abstract]   [Full Text] [Related]  

  • 14. Study on digital teeth selection and virtual teeth arrangement for complete denture.
    Yu X; Cheng X; Dai N; Chen H; Yu C; Sun Y
    Comput Methods Programs Biomed; 2018 Mar; 155():53-60. PubMed ID: 29512504
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Application of computer aided design and rapid prototyping technology for defected maxilla restoration].
    Tong D; Feng HL; Li YS; Zhou ZB
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 Jun; 42(6):333-6. PubMed ID: 17888246
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks.
    Eggbeer D; Bibb R; Williams R
    Proc Inst Mech Eng H; 2005 May; 219(3):195-202. PubMed ID: 15934395
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laboratory fabrication of gold occlusal surfaces for removable and implant-supported prostheses.
    Lloyd PM
    J Prosthodont; 2003 Mar; 12(1):8-12. PubMed ID: 12677605
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of CAD/CAM technology to fabricate a removable partial denture framework.
    Williams RJ; Bibb R; Eggbeer D; Collis J
    J Prosthet Dent; 2006 Aug; 96(2):96-9. PubMed ID: 16911885
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preliminary Clinical Application of Removable Partial Denture Frameworks Fabricated Using Computer-Aided Design and Rapid Prototyping Techniques.
    Ye H; Ning J; Li M; Niu L; Yang J; Sun Y; Zhou Y
    Int J Prosthodont; 2017; 30(4):348-353. PubMed ID: 28697204
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Quantitative evaluation of fabricating complete denture by computer numerical control in manufacturing dentition and baseplate separately plus adhesive molding].
    Wang H; Lv PJ; Wang Y; Sun YC
    Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Oct; 48(5):884-888. PubMed ID: 27752175
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 44.