110 related articles for article (PubMed ID: 19039453)
1. Porcine pericardium as glaucoma implant tube coverage--an experimental study.
Pinto LM; Regatieri CV; Tavares IM; Rigueiro MP
Arq Bras Oftalmol; 2008; 71(5):623-8. PubMed ID: 19039453
[TBL] [Abstract][Full Text] [Related]
2. A comparison of glaucoma drainage implant tube coverage.
Smith MF; Doyle JW; Ticrney JW
J Glaucoma; 2002 Apr; 11(2):143-7. PubMed ID: 11912362
[TBL] [Abstract][Full Text] [Related]
3. Donor sclera versus bovine pericardium as patch graft material in glaucoma implant surgery and the impact of a drainage suture.
van Hoefen Wijsard M; Haan M; Rietveld E; van Rijn LJ
Acta Ophthalmol; 2018 Nov; 96(7):692-698. PubMed ID: 29992745
[TBL] [Abstract][Full Text] [Related]
4. A comparative study of bovine pericardium (periguard) and homologous sclera as lower eyelid spacer graft analogs in New Zealand white rabbits.
DeBacker CM; Dutton JJ; Proia AD; Stone T; Holck DE
Ophthalmic Plast Reconstr Surg; 2000 Mar; 16(2):156-61. PubMed ID: 10749163
[TBL] [Abstract][Full Text] [Related]
5. Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome.
Lankaranian D; Reis R; Henderer JD; Choe S; Moster MR
J Glaucoma; 2008; 17(1):48-51. PubMed ID: 18303385
[TBL] [Abstract][Full Text] [Related]
6. Sutureless human sclera donor patch graft for Ahmed glaucoma valve.
Zeppa L; Romano MR; Capasso L; Tortori A; Majorana MA; Costagliola C
Eur J Ophthalmol; 2010; 20(3):546-51. PubMed ID: 20037905
[TBL] [Abstract][Full Text] [Related]
7. Comparison of different biomaterials for glaucoma drainage devices: part 2.
Ayyala RS; Michelini-Norris B; Flores A; Haller E; Margo CE
Arch Ophthalmol; 2000 Aug; 118(8):1081-4. PubMed ID: 10922202
[TBL] [Abstract][Full Text] [Related]
8. Bovine pericardium versus homologous sclera as wrapping materials for hydroxyapatite ocular implants: an animal study.
DeBacker CM; Dutton JJ; Proia AD; Holck DE; Stone T
Ophthalmic Plast Reconstr Surg; 1999 Sep; 15(5):312-6. PubMed ID: 10511210
[TBL] [Abstract][Full Text] [Related]
9. Use of processed pericardium graft to plug patulous old sclerostomy track during glaucoma shunt revision for exposure.
Shazly TA; Latina MA
Ophthalmic Surg Lasers Imaging; 2012; 43(1):72-5. PubMed ID: 22045593
[TBL] [Abstract][Full Text] [Related]
10. Tube erosion following insertion of a glaucoma drainage device with a pericardial patch graft.
Lama PJ; Fechtner RD
Arch Ophthalmol; 1999 Sep; 117(9):1243-4. PubMed ID: 10496400
[No Abstract] [Full Text] [Related]
11. Comparison of different biomaterials for glaucoma drainage devices.
Ayyala RS; Harman LE; Michelini-Norris B; Ondrovic LE; Haller E; Margo CE; Stevens SX
Arch Ophthalmol; 1999 Feb; 117(2):233-6. PubMed ID: 10037569
[TBL] [Abstract][Full Text] [Related]
12. [A comparison study of glaucoma drainage implant with three different of tube coverages].
Zhou MW; Wang W; Wang SM; Huang DP; Ge J; Zhang XL
Zhonghua Yan Ke Za Zhi; 2013 Feb; 49(2):102-8. PubMed ID: 23714024
[TBL] [Abstract][Full Text] [Related]
13. Heterologous, Fresh, Human Donor Sclera as Patch Graft Material in Glaucoma Drainage Device Surgery.
Tsoukanas D; Xanthopoulou P; Charonis AC; Theodossiadis P; Kopsinis G; Filippopoulos T
J Glaucoma; 2016 Jul; 25(7):558-64. PubMed ID: 26091179
[TBL] [Abstract][Full Text] [Related]
14. Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva.
Kugu S; Erdogan G; Sevim MS; Ozerturk Y
Semin Ophthalmol; 2015 Jan; 30(1):1-5. PubMed ID: 23952816
[TBL] [Abstract][Full Text] [Related]
15. Short-term results of using Lamellar Corneo-scleral patch graft for the Ahmed glaucoma valve implant surgery.
Lam DS; Cheuk W; Lai JS
Yan Ke Xue Bao; 1997 Sep; 13(3):109-12. PubMed ID: 11326858
[TBL] [Abstract][Full Text] [Related]
16. Outcomes of shunt tube coverage with glycerol preserved cornea versus pericardium.
Wigton E; C Swanner J; Joiner W; Feldman A; McGwin G; Huisingh C; Curcio CA; Girkin CA
J Glaucoma; 2014; 23(4):258-61. PubMed ID: 22955016
[TBL] [Abstract][Full Text] [Related]
17. Corneal patch graft repair of exposed glaucoma drainage implants.
Singh M; Chew PT; Tan D
Cornea; 2008 Dec; 27(10):1171-3. PubMed ID: 19034134
[TBL] [Abstract][Full Text] [Related]
18. Expanded polytetrafluoroethylene reinforcement material in glaucoma drain surgery.
Jacob T; LaCour OJ; Burgoyne CF; LaFleur PK; Duzman E
J Glaucoma; 2001 Apr; 10(2):115-20. PubMed ID: 11316093
[TBL] [Abstract][Full Text] [Related]
19. Case Series: Keratolimbal Allograft as a Patch Graft for Glaucoma Drainage Devices.
Ahmed SF; Schmutz M; Mosaed S
J Glaucoma; 2017 Sep; 26(9):e205-e209. PubMed ID: 28731936
[TBL] [Abstract][Full Text] [Related]
20. Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.
Spierer O; Waisbourd M; Golan Y; Newman H; Rachmiel R
BMC Ophthalmol; 2016 Feb; 16():20. PubMed ID: 26920383
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]