These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1469 related articles for article (PubMed ID: 19041893)

  • 21. Detection of high-risk HPV types by the hybrid capture 2 test.
    Terry G; Ho L; Londesborough P; Cuzick J; Mielzynska-Lohnas I; Lorincz A
    J Med Virol; 2001 Sep; 65(1):155-62. PubMed ID: 11505458
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of HPV test versus conventional and automation-assisted Pap screening as potential screening tools for preventing cervical cancer.
    Nieminen P; Vuorma S; Viikki M; Hakama M; Anttila A
    BJOG; 2004 Aug; 111(8):842-8. PubMed ID: 15270934
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison between the Hybrid Capture 2 and the hpVIR real-time PCR for detection of human papillomavirus in women with ASCUS or low grade dysplasia.
    Gustavsson I; Juko-Pecirep I; Backlund I; Wilander E; Gyllensten U
    J Clin Virol; 2009 Jun; 45(2):85-9. PubMed ID: 19451022
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of the f-HPV typing™ and Hybrid Capture II® assays for detection of high-risk HPV genotypes in cervical samples.
    Cañadas MP; Cirigliano V; Darwich L; Sirera G; Coll J; Clotet B; Videla S
    J Virol Methods; 2012 Jul; 183(1):14-8. PubMed ID: 22449759
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of HPV genotyping assays and Hybrid Capture 2 for detection of high-risk HPV in cervical specimens.
    Um TH; Lee EH; Chi HS; Kim JW; Hong YJ; Cha YJ
    Ann Clin Lab Sci; 2011; 41(1):48-55. PubMed ID: 21325255
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Resolution of equivocal results with the Hybrid Capture II high-risk HPV DNA test: a cytologic/histologic review of 191 cases.
    Knoepp SM; Kuebler DL; Wilbur DC
    Diagn Mol Pathol; 2007 Sep; 16(3):125-9. PubMed ID: 17721319
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Type-specific reproducibility of the Roche linear array HPV genotyping test.
    Steinau M; Swan DC; Unger ER
    J Clin Virol; 2008 Aug; 42(4):412-4. PubMed ID: 18424229
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of hybrid capture 2 High-Risk HPV results in the low positive range with cobas® HPV Test results from the ATHENA study.
    Rao A; Sandri MT; Sideri M; Young S; Sharma A; Behrens C
    J Clin Virol; 2013 Sep; 58(1):161-7. PubMed ID: 23895930
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Automation of the linear array HPV genotyping test and its application for routine typing of human papillomaviruses in cervical specimens of women without cytological abnormalities in Switzerland.
    Dobec M; Bannwart F; Kaeppeli F; Cassinotti P
    J Clin Virol; 2009 May; 45(1):23-7. PubMed ID: 19375383
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Human papillomavirus typing with a polymerase chain reaction-based genotyping array compared with type-specific PCR.
    Lin CY; Chao A; Yang YC; Chou HH; Ho CM; Lin RW; Chang TC; Chiou JY; Chao FY; Wang KL; Chien TY; Hsueh S; Huang CC; Chen CJ; Lai CH
    J Clin Virol; 2008 Aug; 42(4):361-7. PubMed ID: 18455959
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Detection and genotyping of human papillomavirus DNA by SPF10 and MY09/11 primers in cervical cells taken from women attending a colposcopy clinic.
    Perrons C; Kleter B; Jelley R; Jalal H; Quint W; Tedder R
    J Med Virol; 2002 Jun; 67(2):246-52. PubMed ID: 11992586
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of the clinical performance of restriction fragment mass polymorphism (RFMP) and Roche linear array HPV test assays for HPV detection and genotyping.
    Lee HP; Cho W; Bae JM; Shin JY; Shin SK; Hwang SY; Min KT; Kim SN; Lee SJ; Kim SO; Yoo WD; Hong SP
    J Clin Virol; 2013 Jun; 57(2):130-5. PubMed ID: 23410688
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of the Digene Hybrid Capture 2 assay and Roche AMPLICOR and LINEAR ARRAY human papillomavirus (HPV) tests in detecting high-risk HPV genotypes in specimens from women with previous abnormal Pap smear results.
    Stevens MP; Garland SM; Rudland E; Tan J; Quinn MA; Tabrizi SN
    J Clin Microbiol; 2007 Jul; 45(7):2130-7. PubMed ID: 17494721
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Restricted cross-reactivity of hybrid capture 2 with nononcogenic human papillomavirus types.
    Castle PE; Schiffman M; Burk RD; Wacholder S; Hildesheim A; Herrero R; Bratti MC; Sherman ME; Lorincz A
    Cancer Epidemiol Biomarkers Prev; 2002 Nov; 11(11):1394-9. PubMed ID: 12433717
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of human papillomavirus-consensus primers for HPV detection by the polymerase chain reaction.
    Harnish DG; Belland LM; Scheid EE; Rohan TE
    Mol Cell Probes; 1999 Feb; 13(1):9-21. PubMed ID: 10024428
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Hybrid Capture 2 vs HPV Consensus kit: comparison of 2 assays for human papillomavirus detection and typing].
    Hantz S; Caly H; Decroisette E; Fermeaux V; Bakeland D; Pascal B; Darreye G; Dussartre C; Rogez S; Aubard Y; Denis F; Alain S
    Pathol Biol (Paris); 2005; 53(8-9):556-62. PubMed ID: 16176861
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of INNO-LiPA genotyping extra and hybrid capture 2 assays for detection of carcinogenic human papillomavirus genotypes.
    Barzon L; Militello V; Pagni S; Palù G
    J Clin Virol; 2012 Nov; 55(3):256-61. PubMed ID: 22877561
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Detection of human papillomavirus DNA in cervical samples: analysis of the new PGMY-PCR compared to the hybrid capture II and MY-PCR assays and a two-step nested PCR assay.
    Giovannelli L; Lama A; Capra G; Giordano V; Aricò P; Ammatuna P
    J Clin Microbiol; 2004 Aug; 42(8):3861-4. PubMed ID: 15297550
    [TBL] [Abstract][Full Text] [Related]  

  • 39. High-risk HPV detection in specimens collected in SurePath preservative fluid: comparison of ambient and refrigerated storage.
    Hardie A; Moore C; Patnick J; Cuschieri K; Graham C; Beadling C; Ellis K; Frew V; Cubie HA
    Cytopathology; 2009 Aug; 20(4):235-41. PubMed ID: 19659956
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of DNA sequencing and Roche Linear array in human papillomavirus (HPV) genotyping.
    Giuliani L; Coletti A; Syrjänen K; Favalli C; Ciotti M
    Anticancer Res; 2006; 26(5B):3939-41. PubMed ID: 17094425
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 74.