696 related articles for article (PubMed ID: 19043177)
41. First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.
Cho B; Poulsen PR; Sloutsky A; Sawant A; Keall PJ
Int J Radiat Oncol Biol Phys; 2009 Jul; 74(3):859-67. PubMed ID: 19480969
[TBL] [Abstract][Full Text] [Related]
42. A limited-angle intrafraction verification (LIVE) system for radiation therapy.
Ren L; Zhang Y; Yin FF
Med Phys; 2014 Feb; 41(2):020701. PubMed ID: 24506590
[TBL] [Abstract][Full Text] [Related]
43. Comparison of 2D and 3D modeled tumor motion estimation/prediction for dynamic tumor tracking during arc radiotherapy.
Liu W; Ma X; Yan H; Chen Z; Nath R; Li H
Phys Med Biol; 2017 May; 62(9):N168-N179. PubMed ID: 28263949
[TBL] [Abstract][Full Text] [Related]
44. Tumour tracking with scanned proton beams: assessing the accuracy and practicalities.
van de Water S; Kreuger R; Zenklusen S; Hug E; Lomax AJ
Phys Med Biol; 2009 Nov; 54(21):6549-63. PubMed ID: 19826204
[TBL] [Abstract][Full Text] [Related]
45. Towards clinical implementation of ultrafast combined kV-MV CBCT for IGRT of lung cancer : Evaluation of registration accuracy based on phantom study.
Arns A; Blessing M; Fleckenstein J; Stsepankou D; Boda-Heggemann J; Simeonova-Chergou A; Hesser J; Lohr F; Wenz F; Wertz H
Strahlenther Onkol; 2016 May; 192(5):312-21. PubMed ID: 26864049
[TBL] [Abstract][Full Text] [Related]
46. Three-dimensional, time-resolved, intrafraction motion monitoring throughout stereotactic liver radiation therapy on a conventional linear accelerator.
Worm ES; Høyer M; Fledelius W; Poulsen PR
Int J Radiat Oncol Biol Phys; 2013 May; 86(1):190-7. PubMed ID: 23414764
[TBL] [Abstract][Full Text] [Related]
47. Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring-Guided Gating for Prostate Cancer Radiation Therapy.
Keall PJ; Ng JA; Juneja P; O'Brien RT; Huang CY; Colvill E; Caillet V; Simpson E; Poulsen PR; Kneebone A; Eade T; Booth JT
Int J Radiat Oncol Biol Phys; 2016 Apr; 94(5):1015-21. PubMed ID: 27026307
[TBL] [Abstract][Full Text] [Related]
48. Online 4D ultrasound guidance for real-time motion compensation by MLC tracking.
Ipsen S; Bruder R; O'Brien R; Keall PJ; Schweikard A; Poulsen PR
Med Phys; 2016 Oct; 43(10):5695. PubMed ID: 27782689
[TBL] [Abstract][Full Text] [Related]
49. Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance.
Létourneau D; Wong R; Moseley D; Sharpe MB; Ansell S; Gospodarowicz M; Jaffray DA
Int J Radiat Oncol Biol Phys; 2007 Mar; 67(4):1229-37. PubMed ID: 17336223
[TBL] [Abstract][Full Text] [Related]
50. A multi-platform approach to image guided radiation therapy (IGRT).
Amies C; Bani-Hashemi A; Celi JC; Grousset G; Ghelmansarai F; Hristov D; Lane D; Mitschke M; Singh A; Shukla H; Stein J; Wofford M
Med Dosim; 2006; 31(1):12-9. PubMed ID: 16551525
[TBL] [Abstract][Full Text] [Related]
51. Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system.
Pang G; Bani-Hashemi A; Au P; O'Brien PF; Rowlands JA; Morton G; Lim T; Cheung P; Loblaw A
Phys Med Biol; 2008 Feb; 53(4):999-1013. PubMed ID: 18263954
[TBL] [Abstract][Full Text] [Related]
52. A proto-type design of a real-tissue phantom for the validation of deformation algorithms and 4D dose calculations.
Szegedi M; Rassiah-Szegedi P; Fullerton G; Wang B; Salter B
Phys Med Biol; 2010 Jul; 55(13):3685-99. PubMed ID: 20530851
[TBL] [Abstract][Full Text] [Related]
53. Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.
Berbeco RI; Jiang SB; Sharp GC; Chen GT; Mostafavi H; Shirato H
Phys Med Biol; 2004 Jan; 49(2):243-55. PubMed ID: 15083669
[TBL] [Abstract][Full Text] [Related]
54. Evaluation of linear accelerator gating with real-time electromagnetic tracking.
Smith RL; Lechleiter K; Malinowski K; Shepard DM; Housley DJ; Afghan M; Newell J; Petersen J; Sargent B; Parikh P
Int J Radiat Oncol Biol Phys; 2009 Jul; 74(3):920-7. PubMed ID: 19394767
[TBL] [Abstract][Full Text] [Related]
55. Daily QA of linear accelerators using only EPID and OBI.
Sun B; Goddu SM; Yaddanapudi S; Noel C; Li H; Cai B; Kavanaugh J; Mutic S
Med Phys; 2015 Oct; 42(10):5584-94. PubMed ID: 26429233
[TBL] [Abstract][Full Text] [Related]
56. Tracking moving organs in real time.
Murphy MJ
Semin Radiat Oncol; 2004 Jan; 14(1):91-100. PubMed ID: 14752737
[TBL] [Abstract][Full Text] [Related]
57. A complementary dual-modality verification for tumor tracking on a gimbaled linac system.
Poels K; Depuydt T; Verellen D; Engels B; Collen C; Heinrich S; Duchateau M; Reynders T; Leysen K; Boussaer M; Steenbeke F; Tournel K; Gevaert T; Storme G; De Ridder M
Radiother Oncol; 2013 Dec; 109(3):469-74. PubMed ID: 24238982
[TBL] [Abstract][Full Text] [Related]
58. Adaptive prediction of internal target motion using external marker motion: a technical study.
Yan H; Yin FF; Zhu GP; Ajlouni M; Kim JH
Phys Med Biol; 2006 Jan; 51(1):31-44. PubMed ID: 16357429
[TBL] [Abstract][Full Text] [Related]
59. Improved quality of intrafraction kilovoltage images by triggered readout of unexposed frames.
Poulsen PR; Jonassen J; Schmidt ML; Jensen C
Med Phys; 2015 Nov; 42(11):6549-57. PubMed ID: 26520745
[TBL] [Abstract][Full Text] [Related]
60. Using cone-beam CT projection images to estimate the average and complete trajectory of a fiducial marker moving with respiration.
Becker N; Smith WL; Quirk S; Kay I
Phys Med Biol; 2010 Dec; 55(24):7439-52. PubMed ID: 21098915
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]