These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

365 related articles for article (PubMed ID: 19044429)

  • 1. A compact UHV deposition system for in situ study of ultrathin films via hard x-ray scattering and spectroscopy.
    Couet S; Diederich T; Schlage K; Röhlsberger R
    Rev Sci Instrum; 2008 Sep; 79(9):093908. PubMed ID: 19044429
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrahigh vacuum/high-pressure flow reactor for surface x-ray diffraction and grazing incidence small angle x-ray scattering studies close to conditions for industrial catalysis.
    van Rijn R; Ackermann MD; Balmes O; Dufrane T; Geluk A; Gonzalez H; Isern H; de Kuyper E; Petit L; Sole VA; Wermeille D; Felici R; Frenken JW
    Rev Sci Instrum; 2010 Jan; 81(1):014101. PubMed ID: 20113115
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Versatile vacuum chamber for in situ surface X-ray scattering studies.
    Carbone D; Plantevin O; Gago R; Mocuta C; Bikondoa O; Alija A; Petit L; Djazuli H; Metzger TH
    J Synchrotron Radiat; 2008 Jul; 15(Pt 4):414-9. PubMed ID: 18552436
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Setup for optimized grazing incidence x-ray absorption experiments on thin films on substrates.
    Maurizio C; Rovezzi M; Bardelli F; Pais HG; D'Acapito F
    Rev Sci Instrum; 2009 Jun; 80(6):063904. PubMed ID: 19566212
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Portable chamber for the study of UHV prepared electrochemical interfaces by hard x-ray diffraction.
    Renner FU; Gründer Y; Zegenhagen J
    Rev Sci Instrum; 2007 Mar; 78(3):033903. PubMed ID: 17411191
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New reactor dedicated to in operando studies of model catalysts by means of surface x-ray diffraction and grazing incidence small angle x-ray scattering.
    Saint-Lager MC; Bailly A; Dolle P; Baudoing-Savois R; Taunier P; Garaudée S; Cuccaro S; Douillet S; Geaymond O; Perroux G; Tissot O; Micha JS; Ulrich O; Rieutord F
    Rev Sci Instrum; 2007 Aug; 78(8):083902. PubMed ID: 17764330
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An ultrahigh vacuum system for in situ studies of thin films and nanostructures by nuclear resonance scattering of synchrotron radiation.
    Stankov S; Rüffer R; Sladecek M; Rennhofer M; Sepiol B; Vogl G; Spiridis N; Slezak T; Korecki J
    Rev Sci Instrum; 2008 Apr; 79(4):045108. PubMed ID: 18447553
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The In situ growth of Nanostructures on Surfaces (INS) endstation of the ESRF BM32 beamline: a combined UHV-CVD and MBE reactor for in situ X-ray scattering investigations of growing nanoparticles and semiconductor nanowires.
    Cantelli V; Geaymond O; Ulrich O; Zhou T; Blanc N; Renaud G
    J Synchrotron Radiat; 2015 May; 22(3):688-700. PubMed ID: 25931085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrahigh-vacuum facility for high-resolution grazing-angle X-ray diffraction at a vertical wiggler source of synchrotron radiation.
    Sakata O; Tanaka Y; Nikolaenko AM; Hashizume H
    J Synchrotron Radiat; 1998 Jul; 5(Pt 4):1222-6. PubMed ID: 16687825
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A compact molecular-beam epitaxy apparatus for in situ soft X-ray magnetic circular dichroism experiments.
    Koide T; Shidara T; Nakajima N; Miyauchi H; Fukutani H
    J Synchrotron Radiat; 1998 May; 5(Pt 3):1038-40. PubMed ID: 15263737
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A compact and low-weight sputtering unit for in situ investigations of thin film growth at synchrotron radiation beamlines.
    Walter P; Dippel AC; Pflaum K; Wernecke J; van den Hurk J; Blume J; Klemradt U
    Rev Sci Instrum; 2015 May; 86(5):053906. PubMed ID: 26026535
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new ultra-high-vacuum variable temperature and high-magnetic-field X-ray magnetic circular dichroism facility at LNLS.
    Figueiredo JJ; Basilio R; Landers R; Garcia F; de Siervo A
    J Synchrotron Radiat; 2009 May; 16(Pt 3):346-51. PubMed ID: 19395797
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A compact UHV X-ray diffractometer for studying surfaces and interfaces.
    Fujii Y; Nakamura T; Kai M; Yoshida K
    J Synchrotron Radiat; 1998 May; 5(Pt 3):887-9. PubMed ID: 15263686
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation.
    Döhrmann R; Botta S; Buffet A; Santoro G; Schlage K; Schwartzkopf M; Bommel S; Risch JF; Mannweiler R; Brunner S; Metwalli E; Müller-Buschbaum P; Roth SV
    Rev Sci Instrum; 2013 Apr; 84(4):043901. PubMed ID: 23635203
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Linear and circularly polarized light to study anisotropy and resonant scattering in magnetic thin films.
    Tolentino HC; Cezar JC; Souza-Neto NM; Ramos AY
    J Synchrotron Radiat; 2005 Mar; 12(Pt 2):168-76. PubMed ID: 15728969
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reactive sputter magnetron reactor for preparation of thin films and simultaneous in situ structural study by X-ray diffraction.
    Bürgi J; Neuenschwander R; Kellermann G; García Molleja J; Craievich AF; Feugeas J
    Rev Sci Instrum; 2013 Jan; 84(1):015102. PubMed ID: 23387690
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and performance of an instrument for soft landing of biomolecular ions on surfaces.
    Hadjar O; Wang P; Futrell JH; Dessiaterik Y; Zhu Z; Cowin JP; Iedema MJ; Laskin J
    Anal Chem; 2007 Sep; 79(17):6566-74. PubMed ID: 17668931
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physical vapor deposition of [EMIM][Tf2N]: a new approach to the modification of surface properties with ultrathin ionic liquid films.
    Cremer T; Killian M; Gottfried JM; Paape N; Wasserscheid P; Maier F; Steinrück HP
    Chemphyschem; 2008 Oct; 9(15):2185-90. PubMed ID: 18846588
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multi-use high/low-temperature and pressure compatible portable chamber for in situ grazing-incidence X-ray scattering studies.
    Ferrer P; Rubio-Zuazo J; Heyman C; Esteban-Betegón F; Castro GR
    J Synchrotron Radiat; 2013 May; 20(Pt 3):474-81. PubMed ID: 23592627
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of a compact ultrahigh vacuum-compatible setup for the analysis of chemical vapor deposition processes.
    Weiss T; Nowak M; Mundloch U; Zielasek V; Kohse-Höinghaus K; Bäumer M
    Rev Sci Instrum; 2014 Oct; 85(10):104104. PubMed ID: 25362422
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.