These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 19044483)
1. An original calibration technique for soft x-ray detectors and its use in the Tore Supra tomographic system. Mazon D; Pacella D; Malard P; Garnier D; Romano A; Bouchand C Rev Sci Instrum; 2008 Oct; 79(10):10E321. PubMed ID: 19044483 [TBL] [Abstract][Full Text] [Related]
2. Characterization of detection efficiency as function of energy for soft x-ray detectors. Pacella D; Mazon D; Romano A; Malard P; Pizzicaroli G Rev Sci Instrum; 2008 Oct; 79(10):10E322. PubMed ID: 19044484 [TBL] [Abstract][Full Text] [Related]
3. Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments. Mazon D; Vezinet D; Pacella D; Moreau D; Gabelieri L; Romano A; Malard P; Mlynar J; Masset R; Lotte P Rev Sci Instrum; 2012 Jun; 83(6):063505. PubMed ID: 22755625 [TBL] [Abstract][Full Text] [Related]
4. Imaging performance of the hybrid pixel detectors XPAD3-S. Brunner FC; Clemens JC; Hemmer C; Morel C Phys Med Biol; 2009 Mar; 54(6):1773-89. PubMed ID: 19258683 [TBL] [Abstract][Full Text] [Related]
5. A curved image-plate detector system for high-resolution synchrotron X-ray diffraction. Sarin P; Haggerty RP; Yoon W; Knapp M; Berghaeuser A; Zschack P; Karapetrova E; Yang N; Kriven WM J Synchrotron Radiat; 2009 Mar; 16(Pt 2):273-82. PubMed ID: 19240340 [TBL] [Abstract][Full Text] [Related]
6. Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak. Jakubowski L; Sadowski MJ; Zebrowski J; Rabinski M; Malinowski K; Mirowski R; Lotte P; Gunn J; Pascal JY; Colledani G; Basiuk V; Goniche M; Lipa M Rev Sci Instrum; 2010 Jan; 81(1):013504. PubMed ID: 20113097 [TBL] [Abstract][Full Text] [Related]
7. An examination of automatic exposure control regimes for two digital radiography systems. Marshall NW Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115 [TBL] [Abstract][Full Text] [Related]
8. Characterization of a 2D soft x-ray tomography camera with discrimination in energy bands. Romano A; Pacella D; Mazon D; Murtas F; Malard P; Gabellieri L; Tilia B; Piergotti V; Corradi G Rev Sci Instrum; 2010 Oct; 81(10):10E523. PubMed ID: 21034051 [TBL] [Abstract][Full Text] [Related]
9. Calculation of absolute intensities from X-ray imaging plates. Cookson DJ J Synchrotron Radiat; 1998 Nov; 5(Pt 6):1375-82. PubMed ID: 16687851 [TBL] [Abstract][Full Text] [Related]
10. A new double-foil soft x-ray array to measure T(e) on the MST reversed field pinch. McGarry MB; Franz P; Den Hartog DJ; Goetz JA Rev Sci Instrum; 2010 Oct; 81(10):10E516. PubMed ID: 21034044 [TBL] [Abstract][Full Text] [Related]
11. Soft x-ray array system with variable filters for the DIII-D tokamak. Hollmann EM; Chousal L; Fisher RK; Hernandez R; Jackson GL; Lanctot MJ; Pidcoe SV; Shankara J; Taussig DA Rev Sci Instrum; 2011 Nov; 82(11):113507. PubMed ID: 22128975 [TBL] [Abstract][Full Text] [Related]
12. The effect of a compression paddle on energy response, calibration and measurement with mammographic dosimeters using ionization chambers and solid-state detectors. Hourdakis CJ; Boziari A; Koumbouli E Phys Med Biol; 2009 Feb; 54(4):1047-59. PubMed ID: 19168939 [TBL] [Abstract][Full Text] [Related]
13. Duplex multiwire proportional x-ray detector for multichord time-resolved soft x-ray and electron temperature measurements on T-10 tokamak. Sushkov AV; Andreev VF; Kravtsov DE Rev Sci Instrum; 2008 Oct; 79(10):10E319. PubMed ID: 19044481 [TBL] [Abstract][Full Text] [Related]
14. A high-spatial-resolution three-dimensional detector array for 30-200 keV X-rays based on structured scintillators. Olsen UL; Schmidt S; Poulsen HF J Synchrotron Radiat; 2008 Jul; 15(Pt 4):363-70. PubMed ID: 18552428 [TBL] [Abstract][Full Text] [Related]
15. Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction. Maas MC; Schaart DR; van der Laan DJ; Bruyndonckx P; Lemaître C; Beekman FJ; van Eijk CW Phys Med Biol; 2009 Apr; 54(7):1893-908. PubMed ID: 19265203 [TBL] [Abstract][Full Text] [Related]
16. Uncertainty in HPGe detector calibrations for in situ gamma-ray spectrometry. Boson J; Johansson L; Ramebäck H; Agren G Radiat Prot Dosimetry; 2009 Jun; 134(2):122-9. PubMed ID: 19429646 [TBL] [Abstract][Full Text] [Related]