360 related articles for article (PubMed ID: 19044523)
1. A 280 GHz single-channel millimeter-wave interferometer system for KSTAR.
Nam YU; Lee KD
Rev Sci Instrum; 2008 Oct; 79(10):10E705. PubMed ID: 19044523
[TBL] [Abstract][Full Text] [Related]
2. Analysis of line integrated electron density using plasma position data on Korea Superconducting Tokamak Advanced Research.
Nam YU; Chung J
Rev Sci Instrum; 2010 Oct; 81(10):10D510. PubMed ID: 21033865
[TBL] [Abstract][Full Text] [Related]
3. Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak.
Feng XD; Zhuang G; Yang ZJ; Gao L; Hu XW
Rev Sci Instrum; 2013 Apr; 84(4):044705. PubMed ID: 23635218
[TBL] [Abstract][Full Text] [Related]
4. Electron cyclotron emission diagnostics on KSTAR tokamak.
Jeong SH; Lee KD; Kogi Y; Kawahata K; Nagayama Y; Mase A; Kwon M
Rev Sci Instrum; 2010 Oct; 81(10):10D922. PubMed ID: 21033954
[TBL] [Abstract][Full Text] [Related]
5. Multichannel microwave interferometer for the levitated dipole experiment.
Boxer AC; Garnier DT; Mauel ME
Rev Sci Instrum; 2009 Apr; 80(4):043502. PubMed ID: 19405655
[TBL] [Abstract][Full Text] [Related]
6. Diagnostics for first plasma and development plan on KSTAR.
Lee JH; Na HK; Lee SG; Bak JG; Seo DC; Seo SH; Oh ST; Ko WH; Chung J; Nam YU; Lee KD; Ka EM; Oh YK; Kwon M; Jeong SH
Rev Sci Instrum; 2010 Jun; 81(6):063502. PubMed ID: 20590236
[TBL] [Abstract][Full Text] [Related]
7. Development of multichannel intermediate frequency system for electron cyclotron emission radiometer on KSTAR Tokamak.
Kogi Y; Sakoda T; Mase A; Ito N; Yokota Y; Yamaguchi S; Nagayama Y; Jeong SH; Kwon M; Kawahata K
Rev Sci Instrum; 2008 Oct; 79(10):10F115. PubMed ID: 19044599
[TBL] [Abstract][Full Text] [Related]
8. Korea Superconducting Tokamak Advanced Research vacuum and gas puffing system.
Seo SH; Kim HT; Kim KP; Kim YO; Kim WC; Yang HL; Oh YK; Jeong SH
Rev Sci Instrum; 2008 Nov; 79(11):116103. PubMed ID: 19045916
[TBL] [Abstract][Full Text] [Related]
9. Design of a Doppler reflectometer for KSTAR.
Lee KD; Nam YU; Seo SH; Kim YS
Rev Sci Instrum; 2014 Nov; 85(11):11D858. PubMed ID: 25430271
[TBL] [Abstract][Full Text] [Related]
10. First neutral beam injection experiments on KSTAR tokamak.
Jeong SH; Chang DH; Kim TS; In SR; Lee KW; Jin JT; Chang DS; Oh BH; Bae YS; Kim JS; Park HT; Watanabe K; Inoue T; Kashiwagi M; Dairaku M; Tobari H; Hanada M
Rev Sci Instrum; 2012 Feb; 83(2):02B102. PubMed ID: 22380259
[TBL] [Abstract][Full Text] [Related]
11. Charge exchange spectroscopy system calibration for ion temperature measurement in KSTAR.
Ko WH; Lee H; Seo D; Kwon M
Rev Sci Instrum; 2010 Oct; 81(10):10D740. PubMed ID: 21033931
[TBL] [Abstract][Full Text] [Related]
12. Diamagnetic loop measurement in Korea Superconducting Tokamak Advanced Research machine.
Bak JG; Lee SG; Kim HS
Rev Sci Instrum; 2011 Jun; 82(6):063504. PubMed ID: 21721688
[TBL] [Abstract][Full Text] [Related]
13. Assessment of the beam path deflection for a vertically installed microwave interferometer in SUNIST.
Zhong H; Ling BL; Tan Y; Gao Z
Rev Sci Instrum; 2016 Aug; 87(8):083501. PubMed ID: 27587117
[TBL] [Abstract][Full Text] [Related]
14. Development of KSTAR Thomson scattering system.
Lee JH; Oh ST; Wi HM
Rev Sci Instrum; 2010 Oct; 81(10):10D528. PubMed ID: 21033883
[TBL] [Abstract][Full Text] [Related]
15. A high speed compact microwave interferometer for density fluctuation measurements in Sino-UNIted Spherical Tokamak.
Zhong H; Tan Y; Liu YQ; Xie HQ; Gao Z
Rev Sci Instrum; 2016 Nov; 87(11):11E109. PubMed ID: 27910671
[TBL] [Abstract][Full Text] [Related]
16. Analysis of edge density fluctuation measured by trial KSTAR beam emission spectroscopy system.
Nam YU; Zoletnik S; Lampert M; Kovácsik Á
Rev Sci Instrum; 2012 Oct; 83(10):10D531. PubMed ID: 23126870
[TBL] [Abstract][Full Text] [Related]
17. In-vessel visible inspection system on KSTAR.
Chung J; Seo DC
Rev Sci Instrum; 2008 Aug; 79(8):083504. PubMed ID: 19044346
[TBL] [Abstract][Full Text] [Related]
18. Development of frequency modulation reflectometer for Korea Superconducting Tokamak Advanced Research tokamak.
Seo SH; Park J; Wi HM; Lee WR; Kim HS; Lee TG; Kim YS; Kang JS; Bog MG; Yokota Y; Mase A
Rev Sci Instrum; 2013 Aug; 84(8):084702. PubMed ID: 24007083
[TBL] [Abstract][Full Text] [Related]
19. Installation of a fast framing visible camera on KSTAR.
Chung J; Lee DK; Seo D; Choi MC
Rev Sci Instrum; 2008 Oct; 79(10):10F510. PubMed ID: 19044655
[TBL] [Abstract][Full Text] [Related]
20. A new multichannel interferometer system on HL-2A.
Zhou Y; Deng ZC; Liu ZT; Yi J; Tang YW; Gao BY; Tian CL; Li YG; Ding XT
Rev Sci Instrum; 2007 Nov; 78(11):113503. PubMed ID: 18052470
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]