These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 19044548)

  • 1. Subterahertz gyrotron developments for collective Thomson scattering in LHD.
    Notake T; Saito T; Tatematsu Y; Kubo S; Shimozuma T; Tanaka K; Nishiura M; Fujii A; Agusu L; Ogawa I; Idehara T
    Rev Sci Instrum; 2008 Oct; 79(10):10E732. PubMed ID: 19044548
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design of collective Thomson scattering system using 77 GHz gyrotron for bulk and tail ion diagnostics in the large helical device.
    Nishiura M; Tanaka K; Kubo S; Saito T; Tatematsu Y; Notake T; Kawahata K; Shimozuma T; Mutoh T
    Rev Sci Instrum; 2008 Oct; 79(10):10E731. PubMed ID: 19044547
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Suppression of spurious mode oscillation in mega-watt 77-GHz gyrotron as a high quality probe beam source for the collective Thomson scattering in LHD.
    Ogasawara S; Kubo S; Nishiura M; Tatematsu Y; Saito T; Tanaka K; Shimozuma T; Yoshimura Y; Igami H; Takahashi H; Ito S; Takita Y; Kobayashi S; Mizuno Y; Okada K; Minami R; Kariya T; Imai T
    Rev Sci Instrum; 2012 Oct; 83(10):10D731. PubMed ID: 23126903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Collective Thomson scattering of a high power electron cyclotron resonance heating beam in LHD (invited).
    Kubo S; Nishiura M; Tanaka K; Shimozuma T; Yoshimura Y; Igami H; Takahash H; Mutoh T; Tamura N; Tatematsu Y; Saito T; Notake T; Korsholm SB; Meo F; Nielsen SK; Salewski M; Stejner M
    Rev Sci Instrum; 2010 Oct; 81(10):10D535. PubMed ID: 21033889
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Commissioning activities and first results from the collective Thomson scattering diagnostic on ASDEX Upgrade (invited).
    Meo F; Bindslev H; Korsholm SB; Furtula V; Leuterer F; Leipold F; Michelsen PK; Nielsen SK; Salewski M; Stober J; Wagner D; Woskov P
    Rev Sci Instrum; 2008 Oct; 79(10):10E501. PubMed ID: 19044487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of first mirror heating for the collective Thomson scattering diagnostic in ITER.
    Salewski M; Meo F; Bindslev H; Furtula V; Korsholm SB; Lauritzen B; Leipold F; Michelsen PK; Nielsen SK; Nonbøl E
    Rev Sci Instrum; 2008 Oct; 79(10):10E729. PubMed ID: 19044545
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Collective Thomson scattering diagnostic with in situ calibration system for velocity space analysis in large helical device.
    Nishiura M; Adachi S; Tanaka K; Kubo S; Kenmochi N; Shimozuma T; Yanai R; Saito T; Nuga H; Seki R
    Rev Sci Instrum; 2022 May; 93(5):053501. PubMed ID: 35649816
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Collective backscattering of gyrotron radiation by small-scale plasma density fluctuations in large helical device.
    Kharchev N; Tanaka K; Kubo S; Igami H; Batanov G; Petrov A; Sarksyan K; Skvortsova N; Azuma Y; Tsuji-Iio S
    Rev Sci Instrum; 2008 Oct; 79(10):10E721. PubMed ID: 19044538
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Temporal evolution of confined fast-ion velocity distributions measured by collective Thomson scattering in TEXTOR.
    Nielsen SK; Bindslev H; Porte L; Hoekzema JA; Korsholm SB; Leipold F; Meo F; Michelsen PK; Michelsen S; Oosterbeek JW; Tsakadze EL; Van Wassenhove G; Westerhof E; Woskov P
    Phys Rev E Stat Nonlin Soft Matter Phys; 2008 Jan; 77(1 Pt 2):016407. PubMed ID: 18351944
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Antenna design for fast ion collective Thomson scattering diagnostic for the international thermonuclear experimental reactor.
    Leipold F; Furtula V; Salewski M; Bindslev H; Korsholm SB; Meo F; Michelsen PK; Moseev D; Nielsen SK; Stejner M
    Rev Sci Instrum; 2009 Sep; 80(9):093501. PubMed ID: 19791936
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast-ion dynamics in the TEXTOR tokamak measured by collective Thomson scattering.
    Bindslev H; Nielsen SK; Porte L; Hoekzema JA; Korsholm SB; Meo F; Michelsen PK; Michelsen S; Oosterbeek JW; Tsakadze EL; Westerhof E; Woskov P;
    Phys Rev Lett; 2006 Nov; 97(20):205005. PubMed ID: 17155690
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of multichannel intermediate frequency system for electron cyclotron emission radiometer on KSTAR Tokamak.
    Kogi Y; Sakoda T; Mase A; Ito N; Yokota Y; Yamaguchi S; Nagayama Y; Jeong SH; Kwon M; Kawahata K
    Rev Sci Instrum; 2008 Oct; 79(10):10F115. PubMed ID: 19044599
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The observation of nonlinear ion cyclotron wave excitation during high-harmonic fast wave heating in the large helical device.
    Kasahara H; Seki T; Kumazawa R; Saito K; Mutoh T; Kubo S; Shimozuma T; Igami H; Yoshimura Y; Takahashi H; Yamada I; Tokuzawa T; Ohdachi S; Morita S; Nomura G; Shimpo F; Komori A; Motojima O; Oosako T; Takase Y; Zhao Y; Kwak J
    Rev Sci Instrum; 2008 Oct; 79(10):10E722. PubMed ID: 19044539
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR.
    Nielsen SK; Salewski M; Bongers W; Korsholm SB; Leipold F; Meo F; Michelsen P; Moseev D; Oosterbeek JW; Stejner M; Westerhof E
    Rev Sci Instrum; 2012 Nov; 83(11):113508. PubMed ID: 23206063
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design and performance of the collective Thomson scattering receiver at ASDEX Upgrade.
    Furtula V; Salewski M; Leipold F; Michelsen PK; Korsholm SB; Meo F; Moseev D; Nielsen SK; Stejner M; Johansen T
    Rev Sci Instrum; 2012 Jan; 83(1):013507. PubMed ID: 22299951
    [TBL] [Abstract][Full Text] [Related]  

  • 16. First experimental tests of powerful 250 GHz gyrotron for future fusion research and collective Thomson scattering diagnostics.
    Denisov GG; Glyavin MY; Fokin AP; Kuftin AN; Tsvetkov AI; Sedov AS; Soluyanova EA; Bakulin MI; Sokolov EV; Tai EM; Morozkin MV; Proyavin MD; Zapevalov VE
    Rev Sci Instrum; 2018 Aug; 89(8):084702. PubMed ID: 30184645
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments.
    Yamada I; Narihara K; Funaba H; Hayashi H; Kohmoto T; Takahashi H; Shimozuma T; Kubo S; Yoshimura Y; Igami H; Tamura N
    Rev Sci Instrum; 2010 Oct; 81(10):10D522. PubMed ID: 21033877
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Glow plasma trigger for electron cyclotron resonance ion sources.
    Vodopianov AV; Golubev SV; Izotov IV; Nikolaev AG; Oks EM; Savkin KP; Yushkov GY
    Rev Sci Instrum; 2010 Feb; 81(2):02A305. PubMed ID: 20192326
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Collective Thomson scattering diagnostic at Wendelstein 7-X.
    Moseev D; Stejner M; Stange T; Abramovic I; Laqua HP; Marsen S; Schneider N; Braune H; Hoefel U; Kasparek W; Korsholm SB; Lechte C; Leipold F; Nielsen SK; Salewski M; Rasmussen J; Weißgerber M; Wolf RC
    Rev Sci Instrum; 2019 Jan; 90(1):013503. PubMed ID: 30709181
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Temporally resolved plasma composition measurements by collective Thomson scattering in TEXTOR (invited).
    Stejner M; Korsholm SB; Nielsen SK; Salewski M; Bindslev H; Leipold F; Michelsen PK; Meo F; Moseev D; Bürger A; Kantor M; de Baar M
    Rev Sci Instrum; 2012 Oct; 83(10):10E307. PubMed ID: 23126967
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.