These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
109 related articles for article (PubMed ID: 19044621)
1. Upgrade of the analyzer design for multipoint measurements by a gold neutral beam probe on the GAMMA 10 tandem mirror. Miyata Y; Yoshikawa M; Oono Y; Mizuguchi M; Nakashima Y; Goshu S; Nakada M; Imai T Rev Sci Instrum; 2008 Oct; 79(10):10F308. PubMed ID: 19044621 [TBL] [Abstract][Full Text] [Related]
2. Study of radial potential fluctuations by using a gold neutral beam probe system. Mizuguchi M; Yoshikawa M; Miyata Y; Goshu S; Nakada M; Oono Y; Nakashima Y; Imai T Rev Sci Instrum; 2008 Oct; 79(10):10F309. PubMed ID: 19044622 [TBL] [Abstract][Full Text] [Related]
3. Measurements of spatial structure of plasma potential and density fluctuations by multichannel heavy ion beam probe on large helical device. Ohshima S; Ido T; Shimizu A; Nishiura M; Nakano H Rev Sci Instrum; 2008 Oct; 79(10):10F320. PubMed ID: 19044633 [TBL] [Abstract][Full Text] [Related]
5. Observation of plasma density fluctuations by a heavy ion beam probe diagnostic with multiple cell array detector on the tokamak ISTTOK. Nedzelskiy IS; Coelho R; Alves D; Silva C; Fernandes H Rev Sci Instrum; 2008 Oct; 79(10):10F319. PubMed ID: 19044632 [TBL] [Abstract][Full Text] [Related]
6. Status of the heavy ion beam probe system in the Large Helical Device. Nishiura M; Ido T; Shimizu A; Nakano H; Kato T; Kato S; Hamada Y; Shevelko VP; Janev RK; Wada M Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02C713. PubMed ID: 18315266 [TBL] [Abstract][Full Text] [Related]
7. Measurement of electrostatic potential fluctuation using heavy ion beam probe in large helical device. Ido T; Shimizu A; Nishiura M; Nakano H; Ohshima S; Kato S; Hamada Y; Yoshimura Y; Kubo S; Shimozuma T; Igami H; Takahashi H; Toi K; Watanabe F Rev Sci Instrum; 2008 Oct; 79(10):10F318. PubMed ID: 19044631 [TBL] [Abstract][Full Text] [Related]
8. A correlation electron cyclotron emission diagnostic and the importance of multifield fluctuation measurements for testing nonlinear gyrokinetic turbulence simulations. White AE; Schmitz L; Peebles WA; Carter TA; Rhodes TL; Doyle EJ; Gourdain PA; Hillesheim JC; Wang G; Holland C; Tynan GR; Austin ME; McKee GR; Shafer MW; Burrell KH; Candy J; DeBoo JC; Prater R; Staebler GM; Waltz RE; Makowski MA Rev Sci Instrum; 2008 Oct; 79(10):103505. PubMed ID: 19044712 [TBL] [Abstract][Full Text] [Related]
10. Ion energy analyzer for measurement of ion turbulent transport. Sokolov V; Sen AK Rev Sci Instrum; 2012 Oct; 83(10):103503. PubMed ID: 23126762 [TBL] [Abstract][Full Text] [Related]
11. Two dimensional density and its fluctuation measurements by using phase imaging method in GAMMA 10. Yoshikawa M; Negishi S; Shima Y; Hojo H; Mase A; Kogi Y; Imai T Rev Sci Instrum; 2010 Oct; 81(10):10D514. PubMed ID: 21033869 [TBL] [Abstract][Full Text] [Related]
12. Poloidal beam emission spectroscopy system for the measurement of density fluctuations in Large Helical Device. Oishi T; Kado S; Ida K; Yoshinuma M; Nakano H; Yamazaki K Rev Sci Instrum; 2010 Oct; 81(10):10D719. PubMed ID: 21033912 [TBL] [Abstract][Full Text] [Related]
13. Magnetic field fluctuation measurement with a heavy ion beam probe in the Large Helical Device. Shimizu A; Ido T; Nishiura M; Nakano H; Ohshima S Rev Sci Instrum; 2008 Oct; 79(10):10F317. PubMed ID: 19044630 [TBL] [Abstract][Full Text] [Related]
15. Radial density profile measurement by using the multichannel microwave interferometer in GAMMA 10. Yoshikawa M; Matsumoto T; Shima Y; Negishi S; Miyata Y; Mizuguchi M; Imai N; Yoneda Y; Hojo H; Itakura A; Imai T Rev Sci Instrum; 2008 Oct; 79(10):10E706. PubMed ID: 19044524 [TBL] [Abstract][Full Text] [Related]
16. Development of radially movable multichannel Reynolds stress probe system for a cylindrical laboratory plasma. Nagashima Y; Inagaki S; Kamakaki K; Arakawa H; Yamada T; Shinohara S; Kawai Y; Yagi M; Fujisawa A; Itoh SI; Itoh K; Takase Y Rev Sci Instrum; 2011 Mar; 82(3):033503. PubMed ID: 21456733 [TBL] [Abstract][Full Text] [Related]
17. Design of a millimeter-wave polarimeter for NSTX-Upgrade and initial test on DIII-D. Zhang J; Peebles WA; Carter TA; Crocker NA; Doyle EJ; Kubota S; Nguyen X; Rhodes TL; Wannberg C; Zeng L Rev Sci Instrum; 2012 Oct; 83(10):10E321. PubMed ID: 23126979 [TBL] [Abstract][Full Text] [Related]
18. High current ion beam transport using solenoids. Hollinger R; Spädtke P Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02B704. PubMed ID: 18315195 [TBL] [Abstract][Full Text] [Related]
19. V-band frequency hopping microwave reflectometer in LHD. Tokuzawa T; Ejiri A; Kawahata K; Tanaka K; Ito Y Rev Sci Instrum; 2008 Oct; 79(10):10F109. PubMed ID: 19044593 [TBL] [Abstract][Full Text] [Related]
20. Imaging free-falling particles for multipoint measurement of plasma fluctuations. Roberts TM; Mauel ME; Abler MC; Makansi BK Rev Sci Instrum; 2015 Aug; 86(8):083510. PubMed ID: 26329195 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]