These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 19044700)

  • 21. [Development of chlorophyll concentration nondestructive measurement instrument based on spectral analysis technology].
    Li QB; Xu YP; Zhang CH; Zhang GJ; Wu JG
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Oct; 29(10):2875-8. PubMed ID: 20038081
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Absorbance detector based on a deep UV light emitting diode for narrow-column HPLC.
    Bui DA; Bomastyk B; Hauser PC
    J Sep Sci; 2013 Oct; 36(19):3152-7. PubMed ID: 23893947
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An economical fluorescence detector for lab-on-a-chip devices with a light emitting photodiode and a low-cost avalanche photodiode.
    Wu J; Liu X; Wang L; Dong L; Pu Q
    Analyst; 2012 Jan; 137(2):519-25. PubMed ID: 22129542
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235nm.
    da Silveira Petruci JF; Liebetanz MG; Cardoso AA; Hauser PC
    J Chromatogr A; 2017 Aug; 1512():143-146. PubMed ID: 28720223
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Miniaturized high throughput detection system for capillary array electrophoresis on chip with integrated light emitting diode array as addressed ring-shaped light source.
    Ren K; Liang Q; Mu X; Luo G; Wang Y
    Lab Chip; 2009 Mar; 9(5):733-6. PubMed ID: 19224025
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Photodiode array on-chip biosensor for the detection of E. coli O157:H7 pathogenic bacteria.
    Song JM; Kwon HT
    Methods Mol Biol; 2009; 503():325-35. PubMed ID: 19151950
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Transient measurement of light-emitting diode characteristic parameters for production lines.
    Zhou S; Liu S
    Rev Sci Instrum; 2009 Sep; 80(9):095102. PubMed ID: 19791959
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An efficient room-temperature silicon-based light-emitting diode.
    Ng WL; Lourenço MA; Gwilliam RM; Ledain S; Shao G; Homewood KP
    Nature; 2001 Mar; 410(6825):192-4. PubMed ID: 11242075
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A simple method for water discrimination based on an light emitting diode (LED) photometer.
    Fonseca A; Raimundo IM
    Anal Chim Acta; 2007 Jul; 596(1):66-72. PubMed ID: 17616241
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A concept of dual optical detection using three light emitting diodes.
    Pokrzywnicka M; Koncki R; Tymecki Ł
    Talanta; 2010 Jun; 82(1):422-5. PubMed ID: 20685488
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A compact portable flow analysis system for the rapid determination of total phosphorus in estuarine and marine waters.
    Gentle BS; Ellis PS; Faber PA; Grace MR; McKelvie ID
    Anal Chim Acta; 2010 Aug; 674(2):117-22. PubMed ID: 20678622
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Localized surface plasmon resonance biosensor integrated with microfluidic chip.
    Huang C; Bonroy K; Reekmans G; Laureyn W; Verhaegen K; De Vlaminck I; Lagae L; Borghs G
    Biomed Microdevices; 2009 Aug; 11(4):893-901. PubMed ID: 19353272
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Radioluminescent light source for the development of optical sensor arrays.
    Holthoff WG; Tehan EC; Bukowski RM; Kent N; Maccraith BD; Bright FV
    Anal Chem; 2005 Jan; 77(2):718-23. PubMed ID: 15649078
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A portable explosive detector based on fluorescence quenching of pyrene deposited on coloured wax-printed μPADs.
    Taudte RV; Beavis A; Wilson-Wilde L; Roux C; Doble P; Blanes L
    Lab Chip; 2013 Nov; 13(21):4164-72. PubMed ID: 23959203
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Multifunctional integrating sphere setup for luminous flux measurements of light emitting diodes.
    Poikonen T; Manninen P; Kärhä P; Ikonen E
    Rev Sci Instrum; 2010 Feb; 81(2):023102. PubMed ID: 20192480
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A LED-LED-based photoplethysmography sensor.
    Stojanovic R; Karadaglic D
    Physiol Meas; 2007 Jun; 28(6):N19-27. PubMed ID: 17664614
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Portable, universal, and visual ion sensing platform based on the light emitting diode-based self-referencing-ion selective field-effect transistor.
    Zhang X; Han Y; Li J; Zhang L; Jia X; Wang E
    Anal Chem; 2014 Feb; 86(3):1380-4. PubMed ID: 24405477
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Novel fused-LEDs devices as optical sensors for colorimetric analysis.
    Lau KT; Baldwin S; Shepherd RL; Dietz PH; Yerzunis WS; Diamond D
    Talanta; 2004 May; 63(1):167-73. PubMed ID: 18969415
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Metal oxide-based monolithic complementary metal oxide semiconductor gas sensor microsystem.
    Graf M; Barrettino D; Taschini S; Hagleitner C; Hierlemann A; Baltes H
    Anal Chem; 2004 Aug; 76(15):4437-45. PubMed ID: 15283585
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fluorescence detection of atmospheric nitrogen dioxide using a blue light-emitting diode as an excitation source.
    Matsumi Y; Taketani F; Takahashi K; Nakayama T; Kawai M; Miyao Y
    Appl Opt; 2010 Jul; 49(19):3762-7. PubMed ID: 20648143
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]