130 related articles for article (PubMed ID: 19045520)
1. A dynamic analytical model for impact evaluation of percutaneous implants.
Swain R; Faulkner G; Raboud D; Wolfaardt J
J Biomech Eng; 2008 Oct; 130(5):051013. PubMed ID: 19045520
[TBL] [Abstract][Full Text] [Related]
2. Simulation of impact test for determining "health" of percutaneous bone anchored implants.
Jones S; Faulkner G; Raboud D; Fyfe K; Wolfaardt J
J Biomech Eng; 2006 Oct; 128(5):647-53. PubMed ID: 16995750
[TBL] [Abstract][Full Text] [Related]
3. [Extended push-out test to characterize the failure of bone-implant interface].
Brandt J; Bierögel C; Holweg K; Hein W; Grellmann W
Biomed Tech (Berl); 2005 Jun; 50(6):201-6. PubMed ID: 16003922
[TBL] [Abstract][Full Text] [Related]
4. Development of implant movement checker for determining dental implant stability.
Wijaya SK; Oka H; Saratani K; Sumikawa T; Kawazoe T
Med Eng Phys; 2004 Jul; 26(6):513-22. PubMed ID: 15234687
[TBL] [Abstract][Full Text] [Related]
5. Cortical and interfacial bone changes around a non-cemented hip implant: simulations using a combined strain/damage remodelling algorithm.
Scannell PT; Prendergast PJ
Med Eng Phys; 2009 May; 31(4):477-88. PubMed ID: 19188086
[TBL] [Abstract][Full Text] [Related]
6. Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer.
Pattijn V; Jaecques SV; De Smet E; Muraru L; Van Lierde C; Van der Perre G; Naert I; Vander Sloten J
Med Eng Phys; 2007 Mar; 29(2):182-90. PubMed ID: 16597507
[TBL] [Abstract][Full Text] [Related]
7. An improved impact technique for monitoring percutaneous implant integrity.
Swain R; Faulkner G; Raboud D; Wolfaardt J
Int J Oral Maxillofac Implants; 2008; 23(2):263-9. PubMed ID: 18548922
[TBL] [Abstract][Full Text] [Related]
8. Computational simulation of dental implant osseointegration through resonance frequency analysis.
Pérez MA; Moreo P; García-Aznar JM; Doblaré M
J Biomech; 2008; 41(2):316-25. PubMed ID: 17976627
[TBL] [Abstract][Full Text] [Related]
9. Numeric simulation of time-dependent remodeling of bone around loaded oral implants.
Eser A; Tonuk E; Akca K; Cehreli MC
Int J Oral Maxillofac Implants; 2009; 24(4):597-608. PubMed ID: 19885399
[TBL] [Abstract][Full Text] [Related]
10. Natural frequency analysis of osseointegration for trans-femoral implant.
Shao F; Xu W; Crocombe A; Ewins D
Ann Biomed Eng; 2007 May; 35(5):817-24. PubMed ID: 17377843
[TBL] [Abstract][Full Text] [Related]
11. Using simulation methods for orthopaedic implant design.
Rickey L
Med Device Technol; 2009 Sep; 20(5):46-7. PubMed ID: 19852183
[TBL] [Abstract][Full Text] [Related]
12. Limiting models for calcification in fibrous tissues adjacent to orthopedic implants: variational indicator functions and influences of implant stiffness.
Harrigan TP
Bull Math Biol; 1998 Jul; 60(4):615-46. PubMed ID: 9659008
[TBL] [Abstract][Full Text] [Related]
13. The dynamic natures of implant loading.
Wang RF; Kang B; Lang LA; Razzoog ME
J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
[TBL] [Abstract][Full Text] [Related]
14. Anatomical hip model for the mechanical testing of hip protectors.
Derler S; Spierings AB; Schmitt KU
Med Eng Phys; 2005 Jul; 27(6):475-85. PubMed ID: 15990064
[TBL] [Abstract][Full Text] [Related]
15. Effects of prosthesis design and impression techniques on human cortical bone strain around oral implants under load.
Akça K; Kokat AM; Sahin S; Iplikcioglu H; Cehreli MC
Med Eng Phys; 2009 Sep; 31(7):758-63. PubMed ID: 19269878
[TBL] [Abstract][Full Text] [Related]
16. The use of modelling to predict implant behaviour.
Ong K; Kurtz S
Med Device Technol; 2008 Sep; 19(5):64-6. PubMed ID: 18947155
[TBL] [Abstract][Full Text] [Related]
17. Histomorphometric evaluation of implant design as a key factor in peri-implant bone response: a preliminary study in a dog model.
Orsini E; Salgarello S; Bubalo M; Lazic Z; Trire A; Martini D; Franchi M; Ruggeri A
Minerva Stomatol; 2009 Jun; 58(6):263-75. PubMed ID: 19516235
[TBL] [Abstract][Full Text] [Related]
18. Human ex vivo bone tissue strains around immediately-loaded implants supporting mandibular fixed prostheses.
Kökat AM; Cömert A; Tekdemir I; Akkocaoğlu M; Akça K; Cehreli MC
Implant Dent; 2009 Apr; 18(2):162-71. PubMed ID: 19359867
[TBL] [Abstract][Full Text] [Related]
19. Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses.
Pendegrass CJ; Goodship AE; Blunn GW
Biomaterials; 2006 Aug; 27(23):4183-91. PubMed ID: 16618500
[TBL] [Abstract][Full Text] [Related]
20. Interface parameters of impact-induced mild traumatic brain injury.
Fijalkowski RJ; Ellingson BM; Stemper BD; Yoganandan N; Gennarelli TA; Pintar FA
Biomed Sci Instrum; 2006; 42():108-13. PubMed ID: 16817594
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]