These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 19045840)

  • 1. Implementation of wireless power transfer and communications for an implantable ocular drug delivery system.
    Tang TB; Smith S; Flynn BW; Stevenson JT; Gundlach AM; Reekie HM; Murray AF; Renshaw D; Dhillon B; Ohtori A; Inoue Y; Terry JG; Walton AJ
    IET Nanobiotechnol; 2008 Sep; 2(3):72-9. PubMed ID: 19045840
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a miniaturised drug delivery system with wireless power transfer and communication.
    Smith S; Tang TB; Terry JG; Stevenson JT; Flynn BW; Reekie HM; Murray AF; Gundlach AM; Renshaw D; Dhillon B; Ohtori A; Inoue Y; Walton AJ
    IET Nanobiotechnol; 2007 Oct; 1(5):80-6. PubMed ID: 17764377
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Low power IC design of the Wireless Monitoring System of the Orthopedic Implants.
    Chen H; Liu M; Jia C; Zhang C; Wang Z
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5767-70. PubMed ID: 18003323
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Wireless powering and data telemetry for biomedical implants.
    Young DJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3221-4. PubMed ID: 19964060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wireless technologies for closed-loop retinal prostheses.
    Ng DC; Bai S; Yang J; Tran N; Skafidas E
    J Neural Eng; 2009 Dec; 6(6):065004. PubMed ID: 19850974
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of dual band power and data telemetry for biomedical implants.
    Guoxing Wang ; Peijun Wang ; Yina Tang ; Wentai Liu
    IEEE Trans Biomed Circuits Syst; 2012 Jun; 6(3):208-15. PubMed ID: 23853143
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulative and experimental research on wireless power transmission technique in implantable medical device.
    Yu Y; Hao H; Wang W; Li L
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():923-6. PubMed ID: 19963736
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A complete data and power telemetry system utilizing BPSK and LSK signaling for biomedical implants.
    Sonkusale S; Luo Z
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3216-9. PubMed ID: 19163391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Miniaturization of implantable wireless power receiver.
    Poon AS
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3217-20. PubMed ID: 19964059
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A generic miniature multi-feature programmable wireless powering headstage ASIC for implantable biomedical systems.
    Kubendran R; Krishnan H; Manola B; John SW; Chappell WJ; Irazoqui PP
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():5617-20. PubMed ID: 22255613
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimal operating frequency in wireless power transmission for implantable devices.
    Poon AS; O'Driscoll S; Meng TH
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5674-9. PubMed ID: 18003300
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Micropower circuits for bidirectional wireless telemetry in neural recording applications.
    Neihart NM; Harrison RR
    IEEE Trans Biomed Eng; 2005 Nov; 52(11):1950-9. PubMed ID: 16285399
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and Implementation of Low Power High-Efficient Transceiver for Body Channel Communications.
    Vijayalakshmi S; Nagarajan V
    J Med Syst; 2019 Feb; 43(4):81. PubMed ID: 30788605
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wireless communication systems for implantable medical devices.
    Panescu D
    IEEE Eng Med Biol Mag; 2008; 27(2):96-101. PubMed ID: 18463025
    [No Abstract]   [Full Text] [Related]  

  • 15. Low-power transceiver analog front-end circuits for bidirectional high data rate wireless telemetry in medical endoscopy applications.
    Chi B; Yao J; Han S; Xie X; Li G; Wang Z
    IEEE Trans Biomed Eng; 2007 Jul; 54(7):1291-9. PubMed ID: 17605360
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A mm-sized wirelessly powered and remotely controlled locomotive implant.
    Pivonka D; Yakovlev A; Poon AS; Meng T
    IEEE Trans Biomed Circuits Syst; 2012 Dec; 6(6):523-32. PubMed ID: 23853253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wireless gigabit data telemetry for large-scale neural recording.
    Kuan YC; Lo YK; Kim Y; Chang MC; Liu W
    IEEE J Biomed Health Inform; 2015 May; 19(3):949-57. PubMed ID: 25823050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Harmonics-based bio-implantable telemetry system.
    Laskovski AN; Yuce MR
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3196-9. PubMed ID: 19163386
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implantable stimulator failures: causes, outcomes, and solutions.
    Liu X; Demosthenous A; Donaldson N
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5787-90. PubMed ID: 18003328
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Micro package of short term wireless implantable microfabricated systems.
    Bu L; Cong P; Kuo HI; Ye X; Ko W
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():6395-9. PubMed ID: 19964419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.