373 related articles for article (PubMed ID: 19051929)
21. High speed two-dimensional protein separation without gel by isoelectric focusing-asymmetrical flow field flow fractionation: application to urinary proteome.
Kim KH; Moon MH
J Proteome Res; 2009 Sep; 8(9):4272-8. PubMed ID: 19653698
[TBL] [Abstract][Full Text] [Related]
22. Rapid and effective focusing in a carrier ampholyte solution isoelectric focusing system: a proteome prefractionation tool.
Tran JC; Doucette AA
J Proteome Res; 2008 Apr; 7(4):1761-6. PubMed ID: 18284188
[TBL] [Abstract][Full Text] [Related]
23. Sampling strategies for capillary isoelectric focusing with electroosmotic zone mobilization assessed by high-resolution dynamic computer simulation.
Takácsi-Nagy A; Kilár F; Páger C; Mosher RA; Thormann W
Electrophoresis; 2012 Mar; 33(6):970-80. PubMed ID: 22655305
[TBL] [Abstract][Full Text] [Related]
24. Carrier ampholytes rehabilitated: gel isoelectric focusing on pH gradients visualized in real-time by automated fluorescence scanning in the HPGE-1000 apparatus.
Gombocz E; Cortez E
Electrophoresis; 1999 Jun; 20(7):1365-72. PubMed ID: 10424457
[TBL] [Abstract][Full Text] [Related]
25. Modeling two-component isoelectric focusing buffers in a vortex-stabilized electrophoresis apparatus.
Tracy NI; Ivory CF
Biotechnol Prog; 2004; 20(1):193-9. PubMed ID: 14763842
[TBL] [Abstract][Full Text] [Related]
26. Peak identification in capillary isoelectric focusing using the concept of relative peak position as determined by two isoelectric point markers.
Wu J; Huang T
Electrophoresis; 2006 Sep; 27(18):3584-90. PubMed ID: 16927345
[TBL] [Abstract][Full Text] [Related]
27. Sequential injection setup for capillary isoelectric focusing combined with MS detection.
Páger C; Dörnyei A; Kilár F
Electrophoresis; 2011 Jul; 32(14):1875-84. PubMed ID: 21769892
[TBL] [Abstract][Full Text] [Related]
28. Synthesis of UV-absorbing and fluorescent carrier ampholyte mixtures and their application for the determination of the operational pH values of buffering membranes used in isoelectric trapping separations.
North R; Hwang A; Lalwani S; Shave E; Vigh G
J Chromatogr A; 2006 Oct; 1130(2):232-7. PubMed ID: 16626722
[TBL] [Abstract][Full Text] [Related]
29. Electrically controlled focusing of proteins and ampholytes between two modified electrolytes. Computer simulation.
Deml M; Pospíchal J
Appl Theor Electrophor; 1994; 4(3):107-15. PubMed ID: 7612692
[TBL] [Abstract][Full Text] [Related]
30. Comparison of different capillary isoelectric focusing methods--use of "narrow pH cuts" of carrier ampholytes as original tools to improve resolution.
Poitevin M; Morin A; Busnel JM; Descroix S; Hennion MC; Peltre G
J Chromatogr A; 2007 Jul; 1155(2):230-6. PubMed ID: 17335834
[TBL] [Abstract][Full Text] [Related]
31. Development of a simple ampholyte-free isoelectric focusing slab electrophoresis for protein fractionation.
Zhan Y; Lemma T; Musteata MF; Pawliszyn J
J Chromatogr A; 2009 Apr; 1216(14):2928-33. PubMed ID: 18752802
[TBL] [Abstract][Full Text] [Related]
32. Native protein blotting after isoelectric focusing in fabric reinforced polyacrylamide gels in carrier ampholyte generated or immobilized pH gradients.
Kinzkofer-Peresch A; Patestos NP; Fauth M; Kögel F; Zok R; Radola BJ
Electrophoresis; 1988 Sep; 9(9):497-511. PubMed ID: 3243247
[TBL] [Abstract][Full Text] [Related]
33. Steady-state protein focusing in carrier ampholyte based isoelectric focusing: Part I-Analytical solution.
Shim J; Yoo K; Dutta P
Electrophoresis; 2017 Mar; 38(5):659-666. PubMed ID: 27874208
[TBL] [Abstract][Full Text] [Related]
34. High-resolution computer simulation of the dynamics of isoelectric focusing using carrier ampholytes: focusing with concurrent electrophoretic mobilization is an isotachophoretic process.
Thormann W; Mosher RA
Electrophoresis; 2006 Mar; 27(5-6):968-83. PubMed ID: 16523465
[TBL] [Abstract][Full Text] [Related]
35. Simulation of desalting that occurs during isoelectric trapping separations.
Hruska V; Gas B; Vigh G
Electrophoresis; 2009 Feb; 30(3):433-43. PubMed ID: 19156763
[TBL] [Abstract][Full Text] [Related]
36. High-resolution computer simulation of the dynamics of isoelectric focusing of proteins.
Thormann W; Huang T; Pawliszyn J; Mosher RA
Electrophoresis; 2004 Jan; 25(2):324-37. PubMed ID: 14743485
[TBL] [Abstract][Full Text] [Related]
37. Carrier ampholyte-free free-flow isoelectric focusing for separation of protein.
Wang S; Zhang L; Sun H; Chu Z; Chen H; Zhao Y; Zhang W
Electrophoresis; 2019 Sep; 40(18-19):2610-2617. PubMed ID: 30977523
[TBL] [Abstract][Full Text] [Related]
38. Steady-state concentration distribution of ampholytes in isoelectric focusing in a linear immobilized pH gradient.
Stoyanov AV; Righetti PG
Electrophoresis; 1998 Jul; 19(10):1596-600. PubMed ID: 9719532
[TBL] [Abstract][Full Text] [Related]
39. Development of a multilane channel system for nongel-based two-dimensional protein separations using isoelectric focusing and asymmetrical flow field-flow fractionation.
Kim KH; Moon MH
Anal Chem; 2009 Feb; 81(4):1715-21. PubMed ID: 19161332
[TBL] [Abstract][Full Text] [Related]
40. Fast preparation of monolithic immobilized pH gradient column by photopolymerization and photografting techniques for isoelectric focusing separation of proteins.
Liang Y; Zhu G; Wang T; Zhang X; Liang Z; Zhang L; Zhang Y
Electrophoresis; 2011 Oct; 32(20):2911-4. PubMed ID: 21948237
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]