These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 1905604)

  • 41. Reference range determination for whole-blood platelet aggregation using the Multiplate analyzer.
    Peerschke EI; Castellone DD; Stroobants AK; Francis J
    Am J Clin Pathol; 2014 Nov; 142(5):647-56. PubMed ID: 25319980
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effects of anticoagulants used during blood collection on human platelet function.
    May JA; Heptinstall S
    Methods Mol Biol; 2004; 272():3-11. PubMed ID: 15226530
    [No Abstract]   [Full Text] [Related]  

  • 43. The effect of anticoagulants, enzyme inhibitors and long term storage on the extraction of known concentrations of methionine enkephalin in human plasma.
    Saad E; Tebb HM; Ashton KJ; Bromham DR
    Life Sci; 1989; 44(10):683-7. PubMed ID: 2467157
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Macrothrombocytosis and idiopathic thrombocytopenic purpura: effect of anticoagulant and prior fixation on the determination of platelet volume using the Coulter system].
    Boneu B; Sie P; Caranobe C; Robert A
    Nouv Rev Fr Hematol (1978); 1986; 28(1):15-8. PubMed ID: 3086835
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The clinical significance of pneumatic tube transport system on platelet indices: EDTA or citrate anticoagulant?
    Kecskemétiné G; Csiki Z; Mile M; Zsóri KS; Shemirani AH
    Int J Lab Hematol; 2017 Aug; 39(4):e102-e105. PubMed ID: 28304145
    [No Abstract]   [Full Text] [Related]  

  • 46. [Anticoagulant-induced pseudo-thrombocytopenia: an important laboratory artifact].
    Radaelli A; Reiner M; Balestra B
    Praxis (Bern 1994); 1996 Nov; 85(48):1550-2. PubMed ID: 8992567
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Electrical impedance and haematocrit of human blood with various anticoagulants.
    Zhao TX
    Physiol Meas; 1993 Aug; 14(3):299-307. PubMed ID: 8401269
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparison of hematologic values in blood samples with lithium heparin or dipotassium ethylenediaminetetraacetic acid anticoagulants in Hispaniolan Amazon parrots (Amazona ventralis).
    Guzman DS; Mitchell MA; Gaunt SD; Beaufrère H; Tully TN
    J Avian Med Surg; 2008 Jun; 22(2):108-13. PubMed ID: 18689071
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The contribution of anticoagulants to platelet dysfunction with extracorporeal circulation.
    Wallace HW; Brooks H; Stein TP; Zimmerman NJ
    J Thorac Cardiovasc Surg; 1976 Nov; 72(5):735-41. PubMed ID: 979314
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Anticoagulants preventing pseudo-thrombocytopenia].
    Nagata T; Tanaka K; Suzuki K; Minoura T; Fujita N; Nakanishi S; Takahashi H; Yoshimura M
    Rinsho Byori; 1992 Jan; 40(1):87-92. PubMed ID: 1545530
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Modulation of blood cell activation by four commonly used anticoagulants.
    Engstad CS; Gutteberg TJ; Osterud B
    Thromb Haemost; 1997 Apr; 77(4):690-6. PubMed ID: 9134644
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A novel approach to inhibit the anticoagulant-induced spontaneous activation of blood platelets--effect of magnesium on platelet release reaction in whole blood.
    Golański J; Pietrucha T; Baj Z; Greger J; Watala C
    Thromb Res; 1997 Jan; 85(2):127-32. PubMed ID: 9058486
    [No Abstract]   [Full Text] [Related]  

  • 53. Agglutination of platelets by a serum factor in the presence of EDTA.
    Gowland E; Kay HE; Spillman JC; Williamson JR
    J Clin Pathol; 1969 Jul; 22(4):460-4. PubMed ID: 4978997
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Multianticoagulant Pseudothrombocytopenia in a Patient with Primary Carcinoma of the Liver with Hypersplenism.
    Pang N; Wang Y; Li P; Li M; Xie J
    Clin Lab; 2024 Mar; 70(3):. PubMed ID: 38469766
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparative effects of anticoagulants on bacterial growth in experimental blood cultures.
    Evans GL; Cekoric T; Searcy RL
    Am J Med Technol; 1968 Feb; 34(2):103-12. PubMed ID: 4970740
    [No Abstract]   [Full Text] [Related]  

  • 56. Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients.
    Wiese J; Didwania A; Kerzner R; Chernow B
    Crit Care Med; 1997 Nov; 25(11):1847-50. PubMed ID: 9366768
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Influence of different anticoagulants on monocyte procoagulant functions and monocyte-platelet aggregates formation.
    Basavaraj MG; Østerud B; Hansen JB
    J Thromb Haemost; 2012 Aug; 10(8):1698-702. PubMed ID: 22712695
    [No Abstract]   [Full Text] [Related]  

  • 58. Elevated lipid peroxide levels in platelets of chronic ischemic heart disease patients.
    Valles J; Aznar J; Santos MT; Fernandez MA
    Thromb Res; 1982 Sep; 27(5):585-9. PubMed ID: 6817450
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Gray platelets - artifact or real?
    Pancione Y; Fumi M; Sale S; Rocco V; Bain BJ
    Am J Hematol; 2016 May; 91(5):538. PubMed ID: 26840765
    [No Abstract]   [Full Text] [Related]  

  • 60. Effects of different anticoagulants on determination of erythrocyte glutathione peroxidase.
    Hussein KS; Jones BE
    Acta Vet Scand; 1981; 22(3-4):472-9. PubMed ID: 6807069
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.