304 related articles for article (PubMed ID: 19057433)
1. Extravascular lung water measurement using transpulmonary thermodilution in children.
Lemson J; Backx AP; van Oort AM; Bouw TP; van der Hoeven JG
Pediatr Crit Care Med; 2009 Mar; 10(2):227-33. PubMed ID: 19057433
[TBL] [Abstract][Full Text] [Related]
2. Effect of the venous catheter site on transpulmonary thermodilution measurement variables.
Schmidt S; Westhoff TH; Hofmann C; Schaefer JH; Zidek W; Compton F; van der Giet M
Crit Care Med; 2007 Mar; 35(3):783-6. PubMed ID: 17255873
[TBL] [Abstract][Full Text] [Related]
3. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model.
Lemson J; de Boode WP; Hopman JC; Singh SK; van der Hoeven JG
Pediatr Crit Care Med; 2008 May; 9(3):313-9. PubMed ID: 18446111
[TBL] [Abstract][Full Text] [Related]
4. Validation of extravascular lung water measurement by transpulmonary thermodilution in a pediatric animal model.
Nusmeier A; Vrancken S; de Boode WP; van der Hoeven JG; Lemson J
Pediatr Crit Care Med; 2014 Jun; 15(5):e226-33. PubMed ID: 24717901
[TBL] [Abstract][Full Text] [Related]
5. Effects of extravascular lung water on the measurement of transpulmonary thermodilution cardiac output in acute respiratory distress syndrome patients.
Huang CC; Kao KC; Fu JY; Hsieh MJ
J Cardiothorac Vasc Anesth; 2011 Jun; 25(3):481-5. PubMed ID: 20829067
[TBL] [Abstract][Full Text] [Related]
6. Transcardiopulmonary thermal dye versus single thermodilution methods for assessment of intrathoracic blood volume and extravascular lung water in major burn resuscitation.
Küntscher MV; Czermak C; Blome-Eberwein S; Dacho A; Germann G
J Burn Care Rehabil; 2003; 24(3):142-7. PubMed ID: 12792233
[TBL] [Abstract][Full Text] [Related]
7. Comparison of a single indicator and gravimetric technique for estimation of extravascular lung water in endotoxemic pigs.
Rossi P; Wanecek M; Rudehill A; Konrad D; Weitzberg E; Oldner A
Crit Care Med; 2006 May; 34(5):1437-43. PubMed ID: 16557161
[TBL] [Abstract][Full Text] [Related]
8. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle.
Pauli C; Fakler U; Genz T; Hennig M; Lorenz HP; Hess J
Intensive Care Med; 2002 Jul; 28(7):947-52. PubMed ID: 12122535
[TBL] [Abstract][Full Text] [Related]
9. Reproducibility of transpulmonary thermodilution measurements in patients with burn shock and hypothermia.
Holm C; Mayr M; Hörbrand F; Tegeler J; Henckel von Donnersmarck G; Mühlbauer W; Pfeiffer UJ
J Burn Care Rehabil; 2005; 26(3):260-5. PubMed ID: 15879748
[TBL] [Abstract][Full Text] [Related]
10. Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children.
Proulx F; Lemson J; Choker G; Tibby SM
Pediatr Crit Care Med; 2011 Jul; 12(4):459-66. PubMed ID: 21263372
[TBL] [Abstract][Full Text] [Related]
11. Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs.
Vrancken SL; Nusmeier A; Hopman JC; Liem KD; van der Hoeven JG; Lemson J; van Heijst AF; de Boode WP
J Clin Monit Comput; 2016 Dec; 30(6):985-994. PubMed ID: 26563187
[TBL] [Abstract][Full Text] [Related]
12. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution.
Sakka SG; Rühl CC; Pfeiffer UJ; Beale R; McLuckie A; Reinhart K; Meier-Hellmann A
Intensive Care Med; 2000 Feb; 26(2):180-7. PubMed ID: 10784306
[TBL] [Abstract][Full Text] [Related]
13. Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: validation of a novel method.
Friesecke S; Heinrich A; Abel P; Felix SB
Crit Care Med; 2009 Jan; 37(1):119-23. PubMed ID: 19050622
[TBL] [Abstract][Full Text] [Related]
14. Arterial pulse wave analysis: An accurate means of determining cardiac output in children.
Kim JJ; Dreyer WJ; Chang AC; Breinholt JP; Grifka RG
Pediatr Crit Care Med; 2006 Nov; 7(6):532-5. PubMed ID: 17006382
[TBL] [Abstract][Full Text] [Related]
15. Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables.
Yu WQ; Zhang Y; Zhang SY; Liang ZY; Fu SQ; Xu J; Liang TB
J Zhejiang Univ Sci B; 2016 Jan; 17(1):60-6. PubMed ID: 26739527
[TBL] [Abstract][Full Text] [Related]
16. The influence of venovenous renal replacement therapy on measurements by the transpulmonary thermodilution technique.
Sakka SG; Hanusch T; Thuemer O; Wegscheider K
Anesth Analg; 2007 Oct; 105(4):1079-82, table of contents. PubMed ID: 17898391
[TBL] [Abstract][Full Text] [Related]
17. Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method.
Kellner P; Schleusener V; Bauerfeind F; Soukup J
J Clin Monit Comput; 2016 Oct; 30(5):629-40. PubMed ID: 26341509
[TBL] [Abstract][Full Text] [Related]
18. The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock: an observational study.
Pathil A; Stremmel W; Schwenger V; Eisenbach C
Eur J Anaesthesiol; 2013 Jan; 30(1):16-20. PubMed ID: 22935958
[TBL] [Abstract][Full Text] [Related]
19. [Evaluation of the thermal technic for the quantitative measurement of extravascular lung water].
Zadrobilek E; Schindler I; Jantsch H; Gilly H; Mauritz W; Draxler V; Sporn P; Steinbereithner K
Anaesthesist; 1985 Nov; 34(11):582-7. PubMed ID: 4091246
[TBL] [Abstract][Full Text] [Related]
20. [Cardiac output determination with transpulmonary thermodilution. An alternative to pulmonary catheterization?].
von Spiegel T; Wietasch G; Bürsch J; Hoeft A
Anaesthesist; 1996 Nov; 45(11):1045-50. PubMed ID: 9012299
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]