These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 19058954)

  • 1. Inter-observer variability of prostate delineation on cone beam computerised tomography images.
    White EA; Brock KK; Jaffray DA; Catton CN
    Clin Oncol (R Coll Radiol); 2009 Feb; 21(1):32-8. PubMed ID: 19058954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inter- and intra-observer variability in contouring of the prostate gland on planning computed tomography and cone beam computed tomography.
    Choi HJ; Kim YS; Lee SH; Lee YS; Park G; Jung JH; Cho BC; Park SH; Ahn H; Kim CS; Yi SY; Ahn SD
    Acta Oncol; 2011 May; 50(4):539-46. PubMed ID: 21391773
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: multi-observer and image multi-modality study.
    Lütgendorf-Caucig C; Fotina I; Stock M; Pötter R; Goldner G; Georg D
    Radiother Oncol; 2011 Feb; 98(2):154-61. PubMed ID: 21176984
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Interobserver variability study for daily cone beam computed tomography registration of prostate volumetric modulated arc therapy].
    Zahra N; Monnet C; Bartha E; Bouilhol G; Boydev C; Courbis M; Le Grévellec M; Bosset M; Zouai M; Fleury B; Clippe S
    Cancer Radiother; 2015 Aug; 19(5):303-7. PubMed ID: 26206733
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of high dose volumetric CT to reduce inter-observer delineation variability and PTV margins for prostate cancer radiotherapy.
    Alasti H; Cho YB; Catton C; Berlin A; Chung P; Bayley A; Vandermeer A; Kong V; Jaffray D
    Radiother Oncol; 2017 Oct; 125(1):118-123. PubMed ID: 28859933
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of inter-observer variability of bladder boundary delineation on cone-beam CT.
    Nishioka K; Shimizu S; Kinoshita R; Inoue T; Onodera S; Yasuda K; Harada K; Nishikawa Y; Onimaru R; Shirato H
    Radiat Oncol; 2013 Jul; 8():185. PubMed ID: 23879876
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical evaluation of soft tissue organ boundary visualization on cone-beam computed tomographic imaging.
    Weiss E; Wu J; Sleeman W; Bryant J; Mitra P; Myers M; Ivanova T; Mukhopadhyay N; Ramakrishnan V; Murphy M; Williamson J
    Int J Radiat Oncol Biol Phys; 2010 Nov; 78(3):929-36. PubMed ID: 20542644
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study.
    Court LE; Dong L; Taylor N; Ballo M; Kitamura K; Lee AK; O'Daniel J; White RA; Cheung R; Kuban D
    Int J Radiat Oncol Biol Phys; 2004 Jun; 59(2):412-8. PubMed ID: 15145157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnitude of observer error using cone beam CT for prostate interfraction motion estimation: effect of reducing scan length or increasing exposure.
    McNair HA; Harris EJ; Hansen VN; Thomas K; South C; Hafeez S; Huddart R; Dearnaley DP
    Br J Radiol; 2015 Oct; 88(1054):20150208. PubMed ID: 26246041
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of cone beam CT registration for prostate radiation therapy: fiducial marker and soft tissue methods.
    Deegan T; Owen R; Holt T; Fielding A; Biggs J; Parfitt M; Coates A; Roberts L
    J Med Imaging Radiat Oncol; 2015 Feb; 59(1):91-8. PubMed ID: 24953244
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasound versus Cone-beam CT image-guided radiotherapy for prostate and post-prostatectomy pretreatment localization.
    Fargier-Voiron M; Presles B; Pommier P; Munoz A; Rit S; Sarrut D; Biston MC
    Phys Med; 2015 Dec; 31(8):997-1004. PubMed ID: 26422200
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of interfraction prostate motion using megavoltage cone beam computed tomography.
    Bylund KC; Bayouth JE; Smith MC; Hass AC; Bhatia SK; Buatti JM
    Int J Radiat Oncol Biol Phys; 2008 Nov; 72(3):949-56. PubMed ID: 19014783
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inter- and intra-observer variability in prostate definition with tissue harmonic and brightness mode imaging.
    Sandhu GK; Dunscombe P; Meyer T; Pavamani S; Khan R
    Int J Radiat Oncol Biol Phys; 2012 Jan; 82(1):e9-16. PubMed ID: 21489703
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prostate bed motion may cause geographic miss in post-prostatectomy image-guided intensity-modulated radiotherapy.
    Bell LJ; Cox J; Eade T; Rinks M; Kneebone A
    J Med Imaging Radiat Oncol; 2013 Dec; 57(6):725-32. PubMed ID: 24283563
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy.
    Deurloo KE; Steenbakkers RJ; Zijp LJ; de Bois JA; Nowak PJ; Rasch CR; van Herk M
    Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):228-38. PubMed ID: 15629616
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A general methodology for three-dimensional analysis of variation in target volume delineation.
    Remeijer P; Rasch C; Lebesque JV; van Herk M
    Med Phys; 1999 Jun; 26(6):931-40. PubMed ID: 10436894
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluating the accuracy of the XVI dual registration tool compared with manual soft tissue matching to localise tumour volumes for post-prostatectomy patients receiving radiotherapy.
    Campbell A; Owen R; Brown E; Pryor D; Bernard A; Lehman M
    J Med Imaging Radiat Oncol; 2015 Aug; 59(4):527-534. PubMed ID: 26109083
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Consistency in electronic portal imaging registration in prostate cancer radiation treatment verification.
    Berthelet E; Truong PT; Zavgorodni S; Moravan V; Liu MC; Runkel J; Bendorffe B; Sayers D
    Radiat Oncol; 2006 Sep; 1():37. PubMed ID: 16984655
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Examining margin reduction and its impact on dose distribution for prostate cancer patients undergoing daily cone-beam computed tomography.
    Hammoud R; Patel SH; Pradhan D; Kim J; Guan H; Li S; Movsas B
    Int J Radiat Oncol Biol Phys; 2008 May; 71(1):265-73. PubMed ID: 18406890
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A cone beam CT-Based Study for Clinical Target Definition Using Pelvic Anatomy During Postprostatectomy Radiotherapy.
    Showalter TN; Nawaz AO; Xiao Y; Galvin JM; Valicenti RK
    Int J Radiat Oncol Biol Phys; 2008 Feb; 70(2):431-6. PubMed ID: 17869021
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.