  • 1. Neutron emission spectroscopy results for internal transport barrier and mode conversion ion cyclotron resonance heating experiments at JET.
    Giacomelli L; Hjalmarsson A; Källne J; Hellesen C; Tardocchi M; Gorini G; Van Eester D; Lerche E; Johnson T; Kiptily V; Conroy S; Andersson Sundén E; Ericsson G; Gatu Johnson M; Sjöstrand H; Weiszflog M;
    Rev Sci Instrum; 2008 Oct; 79(10):10E514. PubMed ID: 19068506
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neutron spectrometry of JET discharges with ICRH-acceleration of helium beam ions.
    Gatu Johnson M; Andersson Sundén E; Cecconello M; Conroy S; Ericsson G; Eriksson J; Gorini G; Hellesen C; Kiptily V; Nocente M; Sangaroon S; Sharapov SE; Tardocchi M; van Eester D; Weiszflog M;
    Rev Sci Instrum; 2010 Oct; 81(10):10D336. PubMed ID: 21058459
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simulations of neutral beam injection and ion cyclotron resonance heating synergy in high power EAST scenarios.
    Yang DK; Liao LY; Li YH; Zhong GQ; Zhang XJ; Zhang W; Hao BL; Hu LQ; Wan BN; Hu ZM; Zhang YM; Gorini G; Nocente M; Tardocchi M; Li XQ; Xiao CJ; Fan TS
    Rev Sci Instrum; 2022 Nov; 93(11):113501. PubMed ID: 36461431
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurements of neutron fluxes from tokamak plasmas using a compact neutron spectrometer.
    Iliasova MV; Shevelev AE; Khilkevitch EM; Lebedev SV; Askinazi LG; Kornev VA; Minaev VB; Tukachinsky AS; Doinikov DN; Polunovsky IA; Naidenov VO; Gin DB
    Rev Sci Instrum; 2021 Apr; 92(4):043560. PubMed ID: 34243451
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Identification of minority ion-cyclotron emission during radio frequency heating in the JET tokamak.
    Cottrell GA
    Phys Rev Lett; 2000 Mar; 84(11):2397-400. PubMed ID: 11018894
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Velocity-space sensitivities of neutron emission spectrometers at the tokamaks JET and ASDEX Upgrade in deuterium plasmas.
    Jacobsen AS; Binda F; Cazzaniga C; Eriksson J; Hjalmarsson A; Nocente M; Salewski M; Tardini G; ;
    Rev Sci Instrum; 2017 Jul; 88(7):073506. PubMed ID: 28764505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Deuterium density profile determination at JET using a neutron camera and a neutron spectrometer.
    Eriksson J; Castegnetti G; Conroy S; Ericsson G; Giacomelli L; Hellesen C;
    Rev Sci Instrum; 2014 Nov; 85(11):11E106. PubMed ID: 25430285
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neutron emission spectroscopy of D plasmas at JET with a compact liquid scintillating neutron spectrometer.
    Giacomelli L; Belli F; Binda F; Conroy SW; Eriksson J; Milocco A; Popovicev S; Syme DB;
    Rev Sci Instrum; 2018 Oct; 89(10):10I113. PubMed ID: 30399806
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited).
    Murari A; Angelone M; Bonheure G; Cecil E; Craciunescu T; Darrow D; Edlington T; Ericsson G; Gatu-Johnson M; Gorini G; Hellesen C; Kiptily V; Mlynar J; Perez von Thun C; Pillon M; Popovichev S; Syme B; Tardocchi M; Zoita VL;
    Rev Sci Instrum; 2010 Oct; 81(10):10E136. PubMed ID: 21061488
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Probing internal transport barriers with heat pulses in JET.
    Mantica P; Van Eester D; Garbet X; Imbeaux F; Laborde L; Mantsinen M; Marinoni A; Mazon D; Moreau D; Hawkes N; Joffrin E; Kiptily V; Pinches S; Salmi A; Sharapov S; Thyagaraja A; Voitsekhovitch I; de Vries P; Zastrow KD
    Phys Rev Lett; 2006 Mar; 96(9):095002. PubMed ID: 16606270
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A compact stilbene crystal neutron spectrometer for EAST D-D plasma neutron diagnostics.
    Zhang X; Yuan X; Xie X; Chen Z; Peng X; Chen J; Zhang G; Li X; Fan T; Zhong G; Hu L; Wan B
    Rev Sci Instrum; 2013 Mar; 84(3):033506. PubMed ID: 23556820
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New method for time alignment and time calibration of the TOFOR time-of-flight neutron spectrometer at JET.
    Eriksson B; Conroy S; Ericsson G; Eriksson J; Giacomelli L; Hjalmarsson A; Weiszflog M;
    Rev Sci Instrum; 2021 Mar; 92(3):033538. PubMed ID: 33820020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Forward fitting of experimental data from a NE213 neutron detector installed with the magnetic proton recoil upgraded spectrometer at JET.
    Binda F; Ericsson G; Eriksson J; Hellesen C; Conroy S; Sundén EA;
    Rev Sci Instrum; 2014 Nov; 85(11):11E123. PubMed ID: 25430302
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ion cyclotron resonance heating (ICRH) systems for the Keda Mirror with AXisymmetry (KMAX).
    Liu M; Yi H; Lin M; Wang Y; Shi P; Zheng J; Sun X
    Rev Sci Instrum; 2017 May; 88(5):053505. PubMed ID: 28571457
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The 12C(3He,pγ)14N reaction cross section for γ-ray spectroscopy simulation of fusion plasmas.
    Proverbio I; Nocente M; Kiptily VG; Tardocchi M; Gorini G;
    Rev Sci Instrum; 2010 Oct; 81(10):10D320. PubMed ID: 21058453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An initial measurement of a fast neutral spectrum for ion cyclotron range of frequency heated plasma using two-channel compact neutral particle analyzers in KSTAR.
    Kim SH; Wang SJ; Park M; Kim SK
    Rev Sci Instrum; 2013 Nov; 84(11):113504. PubMed ID: 24289396
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characteristics of electron heat transport of plasma with an electron internal-transport barrier in the large helical device.
    Ida K; Shimozuma T; Funaba H; Narihara K; Kubo S; Murakami S; Wakasa A; Yokoyama M; Takeiri Y; Watanabe KY; Tanaka K; Yoshinuma M; Liang Y; Ohyabu N;
    Phys Rev Lett; 2003 Aug; 91(8):085003. PubMed ID: 14525247
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET.
    Jacobsen AS; Salewski M; Eriksson J; Ericsson G; Hjalmarsson A; Korsholm SB; Leipold F; Nielsen SK; Rasmussen J; Stejner M;
    Rev Sci Instrum; 2014 Nov; 85(11):11E103. PubMed ID: 25430282
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A compact stilbene crystal neutron spectrometer for NBI-heated plasma neutron diagnostics at EAST.
    Liao LY; Zhang YM; Hu ZM; Yang DK; Ge LJ; Sun JQ; Zhong GQ; Hu LQ; Wan BN; Gorini G; Nocente M; Tardocchi M; Li XQ; Fan TS
    Rev Sci Instrum; 2021 Apr; 92(4):043506. PubMed ID: 34243369
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Observation of ion-cyclotron-frequency mode-conversion flow drive in tokamak plasmas.
    Lin Y; Rice JE; Wukitch SJ; Greenwald MJ; Hubbard AE; Ince-Cushman A; Lin L; Porkolab M; Reinke ML; Tsujii N
    Phys Rev Lett; 2008 Dec; 101(23):235002. PubMed ID: 19113561
    [TBL] [Abstract][Full Text] [Related]  