These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 19070226)

  • 1. Measurement of electron density in dual-energy x-ray CT with monochromatic x rays and evaluation of its accuracy.
    Tsunoo T; Torikoshi M; Ohno Y; Uesugi K; Yagi N
    Med Phys; 2008 Nov; 35(11):4924-32. PubMed ID: 19070226
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical Note: Relation between dual-energy subtraction of CT images for electron density calibration and virtual monochromatic imaging.
    Saito M
    Med Phys; 2015 Jul; 42(7):4088-93. PubMed ID: 26133609
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electron density measurement with dual-energy x-ray CT using synchrotron radiation.
    Torikoshi M; Tsunoo T; Sasaki M; Endo M; Noda Y; Ohno Y; Kohno T; Hyodo K; Uesugi K; Yagi N
    Phys Med Biol; 2003 Mar; 48(5):673-85. PubMed ID: 12696802
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Empirical beam hardening correction (EBHC) for CT.
    Kyriakou Y; Meyer E; Prell D; Kachelriess M
    Med Phys; 2010 Oct; 37(10):5179-87. PubMed ID: 21089751
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations.
    Bazalova M; Carrier JF; Beaulieu L; Verhaegen F
    Phys Med Biol; 2008 May; 53(9):2439-56. PubMed ID: 18421124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Improvement of Beam Hardening Effects of Virtual Monochromatic Image in Dual-energy CT: A Electron Density Phantom Study].
    Hirairi T; Ichikawa K; Urikura A; Sugiyama M; Asegawa S; Matsunami T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2020; 76(2):168-176. PubMed ID: 32074525
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Exact dual energy material decomposition from inconsistent rays (MDIR).
    Maass C; Meyer E; Kachelriess M
    Med Phys; 2011 Feb; 38(2):691-700. PubMed ID: 21452706
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical Note: exploring the limit for the conversion of energy-subtracted CT number to electron density for high-atomic-number materials.
    Saito M; Tsukihara M
    Med Phys; 2014 Jul; 41(7):071701. PubMed ID: 24989370
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single and dual energy attenuation correction in PET/CT in the presence of iodine based contrast agents.
    Rehfeld NS; Heismann BJ; Kupferschläger J; Aschoff P; Christ G; Pfannenberg AC; Pichler BJ
    Med Phys; 2008 May; 35(5):1959-69. PubMed ID: 18561672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Derivation of linear attenuation coefficients from CT numbers for low-energy photons.
    Watanabe Y
    Phys Med Biol; 1999 Sep; 44(9):2201-11. PubMed ID: 10495115
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship.
    Saito M
    Med Phys; 2012 Apr; 39(4):2021-30. PubMed ID: 22482623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electron density and effective atomic number estimation in a maximum a posteriori framework for dual-energy computed tomography.
    Simard M; Bär E; Blais D; Bouchard H
    Med Phys; 2020 Sep; 47(9):4137-4149. PubMed ID: 32491193
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimized low-kV spectrum of dual-energy CT equipped with high-kV tin filtration for electron density measurements.
    Saito M
    Med Phys; 2011 Jun; 38(6):2850-8. PubMed ID: 21815360
    [TBL] [Abstract][Full Text] [Related]  

  • 14. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.
    Kinahan PE; Hasegawa BH; Beyer T
    Semin Nucl Med; 2003 Jul; 33(3):166-79. PubMed ID: 12931319
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung.
    Disher B; Hajdok G; Wang A; Craig J; Gaede S; Battista JJ
    Phys Med Biol; 2013 Jun; 58(12):4157-74. PubMed ID: 23689060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative image-based spectral reconstruction for computed tomography.
    Heismann B; Balda M
    Med Phys; 2009 Oct; 36(10):4471-85. PubMed ID: 19928078
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.
    Torikoshi M; Tsunoo T; Endo M; Noda K; Kumada M; Yamada S; Soga F; Hyodo K
    J Biomed Opt; 2001 Jul; 6(3):371-7. PubMed ID: 11516330
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Feasibility study for DEXA using synchrotron CT at 20-35 keV.
    Midgley SM
    Phys Med Biol; 2013 Feb; 58(4):1185-205. PubMed ID: 23369847
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Handling Density Conversion in TPS].
    Isobe T; Mori Y; Takei H; Sato E; Tadano K; Kobayashi D; Tomita T; Sakae T
    Igaku Butsuri; 2016; 36(3):156-160. PubMed ID: 28442653
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dual energy CT: how well can pseudo-monochromatic imaging reduce metal artifacts?
    Kuchenbecker S; Faby S; Sawall S; Lell M; Kachelrieß M
    Med Phys; 2015 Feb; 42(2):1023-36. PubMed ID: 25652515
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.