These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 19071710)

  • 1. The synthesis of new polymeric sorbent and its application in preconcentration of cadmium and lead in water samples.
    Senkal BF; Ince M; Yavuz E; Yaman M
    Talanta; 2007 May; 72(3):962-7. PubMed ID: 19071710
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Separation and preconcentration of Cd(II), Cu(II), Ni(II), and Pb(II) in water and food samples using Amberlite XAD-2 functionalized with 3-(2-nitrophenyl)-1H-1,2,4-triazole-5(4H)-thione and determination by inductively coupled plasma-atomic emission spectrometry.
    Kumar BN; Ramana DK; Harinath Y; Seshaiah K; Wang MC
    J Agric Food Chem; 2011 Oct; 59(20):11352-8. PubMed ID: 21919486
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Separation and preconcentration of trace manganese from various samples with Amberlyst 36 column and determination by flame atomic absorption spectrometry.
    Kendüzler E; Türker AR; Yalçınkaya O
    Talanta; 2006 Jun; 69(4):835-40. PubMed ID: 18970645
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biosorption and preconcentration of lead and cadmium on waste Chinese herb Pang Da Hai.
    Liu Y; Chang X; Guo Y; Meng S
    J Hazard Mater; 2006 Jul; 135(1-3):389-94. PubMed ID: 16488078
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of lead in milk and yoghurt samples by solid phase extraction using a novel aminothioazole-polymeric resin.
    Er C; Filiz Senkal B; Yaman M
    Food Chem; 2013 Apr; 137(1-4):55-61. PubMed ID: 23199990
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Synthesis of salicylaldehyde-modified mesoporous silica and its application as a new sorbent for separation, preconcentration and determination of uranium by inductively coupled plasma atomic emission spectrometry.
    Jamali MR; Assadi Y; Shemirani F; Hosseini MR; Kozani RR; Masteri-Farahani M; Salavati-Niasari M
    Anal Chim Acta; 2006 Oct; 579(1):68-73. PubMed ID: 17723729
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Solid phase extraction method for the determination of lead, nickel, copper and manganese by flame atomic absorption spectrometry using sodium bispiperdine-1,1'-carbotetrathioate (Na-BPCTT) in water samples.
    Rekha D; Suvardhan K; Kumar JD; Subramanyam P; Prasad PR; Lingappa Y; Chiranjeevi P
    J Hazard Mater; 2007 Jul; 146(1-2):131-6. PubMed ID: 17208372
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Azocalix[4]pyrrole Amberlite XAD-2: new polymeric chelating resins for the extraction, preconcentration and sequential separation of Cu(II), Zn(II) and Cd(II) in natural water samples.
    Jain VK; Mandalia HC; Gupte HS; Vyas DJ
    Talanta; 2009 Oct; 79(5):1331-40. PubMed ID: 19635367
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions in environmental samples by membrane filtration prior to their flame atomic absorption spectrometric determinations.
    Divrikli U; Kartal AA; Soylak M; Elci L
    J Hazard Mater; 2007 Jul; 145(3):459-64. PubMed ID: 17175100
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Synthesis and application of imprinted polyvinylimidazole-silica hybrid copolymer for Pb2+ determination by flow-injection thermospray flame furnace atomic absorption spectrometry.
    Tarley CR; Andrade FN; de Oliveira FM; Corazza MZ; de Azevedo LF; Segatelli MG
    Anal Chim Acta; 2011 Oct; 703(2):145-51. PubMed ID: 21889628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Online preconcentration for the determination of lead, cadmium and copper by slotted tube atom trap (STAT)-flame atomic absorption spectrometry.
    Kaya G; Yaman M
    Talanta; 2008 May; 75(4):1127-33. PubMed ID: 18585193
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ionic liquid-modified silica as sorbent for preconcentration of cadmium prior to its determination by flame atomic absorption spectrometry in water samples.
    Liang P; Peng L
    Talanta; 2010 Apr; 81(1-2):673-7. PubMed ID: 20188980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Solid phase extraction and determination of nickel in water samples by using novel thiol-containing sulfonamide polymeric resin and atomic absorption spectrophotometer.
    Karaaslan NM; Senkal BF; Er C; Avci H; Yaman M
    Guang Pu Xue Yu Guang Pu Fen Xi; 2011 Aug; 31(8):2243-8. PubMed ID: 22007425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimization of the preconcentration system of cadmium with 1(2-thiazolylazo)-p-cresol using a knotted reactor and flame atomic absorption spectrometric detection.
    Cerutti S; Ferreira SL; Gásquez JA; Olsina RA; Martinez LD
    J Hazard Mater; 2004 Aug; 112(3):279-83. PubMed ID: 15302449
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Solid-phase extraction system for Pb (II) ions enrichment based on multiwall carbon nanotubes coupled on-line to flame atomic absorption spectrometry.
    Barbosa AF; Segatelli MG; Pereira AC; de Santana Santos A; Kubota LT; Luccas PO; Tarley CR
    Talanta; 2007 Mar; 71(4):1512-9. PubMed ID: 19071484
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preconcentration of gold ions from water samples by modified organo-nanoclay sorbent prior to flame atomic absorption spectrometry determination.
    Afzali D; Mostafavi A; Mirzaei M
    J Hazard Mater; 2010 Sep; 181(1-3):957-61. PubMed ID: 20554379
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of lead and nickel in environmental samples by flame atomic absorption spectrometry after column solid-phase extraction on Ambersorb-572 with EDTA.
    Baytak S; Türker AR
    J Hazard Mater; 2006 Feb; 129(1-3):130-6. PubMed ID: 16198051
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS).
    Duran C; Gundogdu A; Bulut VN; Soylak M; Elci L; Sentürk HB; Tüfekci M
    J Hazard Mater; 2007 Jul; 146(1-2):347-55. PubMed ID: 17223260
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On-line preconcentration of copper as its pyrocatechol violet complex on Chromosorb 105 for flame atomic absorption spectrometric determinations.
    Buke B; Divrikli U; Soylak M; Elci L
    J Hazard Mater; 2009 Apr; 163(2-3):1298-302. PubMed ID: 18762371
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automatic on line preconcentration and determination of lead in water by ICP-AES using a TS-microcolumn.
    Zougagh M; García de Torres A; Vereda Alonso E; Cano Pavón JM
    Talanta; 2004 Feb; 62(3):503-10. PubMed ID: 18969325
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.