These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
57 related articles for article (PubMed ID: 1907942)
1. [Primary correction of orbital fractures using PDS-foil]. Hidding J; Deitmer T; Hemprich A; Ahrberg W Fortschr Kiefer Gesichtschir; 1991; 36():195-6. PubMed ID: 1907942 [No Abstract] [Full Text] [Related]
2. [Use of a cup-shaped implant of polydioxanone in orbital-malar fractures]. Cantaloube D; Rives JM; Bauby F; Andreani JF; Dumas B Rev Stomatol Chir Maxillofac; 1989; 90(1):48-51. PubMed ID: 2497509 [TBL] [Abstract][Full Text] [Related]
3. [Long-term results following orbital comminuted fractures with special reference of orbital floor reconstruction using an absorbable PDS-plate]. Krainau R; Klesper B; Hellner D; Reinhardt R Fortschr Kiefer Gesichtschir; 1991; 36():217-8. PubMed ID: 1907944 [No Abstract] [Full Text] [Related]
4. [Indication for, technique and results of reconstruction of traumatic defects of the bony orbital floor]. Hessling KH; Eckardt A; Schmelzeisen R; Mayer H Fortschr Kiefer Gesichtschir; 1991; 36():207-9. PubMed ID: 1907943 [No Abstract] [Full Text] [Related]
5. Orbital floor reconstruction with flexible Ethisorb patches: a retrospective long-term follow-up study. Jank S; Emshoff R; Schuchter B; Strobl H; Brandlmaier I; Norer B Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Jan; 95(1):16-22. PubMed ID: 12539022 [TBL] [Abstract][Full Text] [Related]
6. Reconstruction of orbital floor with polydioxanone plate. Iizuka T; Mikkonen P; Paukku P; Lindqvist C Int J Oral Maxillofac Surg; 1991 Apr; 20(2):83-7. PubMed ID: 1904906 [TBL] [Abstract][Full Text] [Related]
7. [Orbital floor reconstruction. Comparison of a new perforated 0.15 mm thick PDS layer with established titanium dynamic mesh]. Dacho A; Steffen H; Ziegler CM; Conradt C; Dietz A HNO; 2002 Jan; 50(1):21-8. PubMed ID: 11963783 [TBL] [Abstract][Full Text] [Related]
8. [Animal experiments for the determination of in-vivo absorption of PDS osteosynthesis material]. Schliephake H; Neukam FW; Klosa D Fortschr Kiefer Gesichtschir; 1991; 36():252-5. PubMed ID: 1907945 [No Abstract] [Full Text] [Related]
9. A novel high-resolution magnetic resonance imaging microscopy coil as an alternative to the multislice computed tomography in postoperative imaging of orbital fractures and computer-based volume measurement. Kolk A; Pautke C; Wiener E; Ploder O; Neff A J Oral Maxillofac Surg; 2005 Apr; 63(4):492-8. PubMed ID: 15789321 [TBL] [Abstract][Full Text] [Related]
10. Preforming of polydioxanone sheets for orbital wall fractures - A technical note. Kruber D; Hierl T; Doerfler HM; Huempfner-Hierl H; Krause M J Craniomaxillofac Surg; 2018 Jul; 46(7):1159-1161. PubMed ID: 29793778 [TBL] [Abstract][Full Text] [Related]
11. Reconstruction of orbital floor fracture with polyglactin 910/polydioxanon patch (ethisorb): a retrospective study. Büchel P; Rahal A; Seto I; Iizuka T J Oral Maxillofac Surg; 2005 May; 63(5):646-50. PubMed ID: 15883939 [TBL] [Abstract][Full Text] [Related]
12. [Bridging-over of 2-walled orbital defects using biological absorbable plastic foil. An animal study]. Merten HA; Patyk A; Wiese KG; Luhn HG Fortschr Kiefer Gesichtschir; 1991; 36():249-52. PubMed ID: 1869198 [No Abstract] [Full Text] [Related]
14. Evaluation of reconstructed orbital wall fractures: high-resolution MRI using a microscopy surface coil versus 16-slice MSCT. Wiener E; Kolk A; Neff A; Settles M; Rummeny E Eur Radiol; 2005 Jun; 15(6):1250-5. PubMed ID: 15711842 [TBL] [Abstract][Full Text] [Related]
15. Endoscopic exploration of the orbital floor: a technique for transantral grafting of floor blowout fractures. Mohammad JA; Warnke PH; Shenaq SM J Craniomaxillofac Trauma; 1998; 4(2):16-9; discussion 15. PubMed ID: 11951428 [TBL] [Abstract][Full Text] [Related]
16. Surgical treatment of posttraumatic enophthalmos with diced medpor implants through mini-lateral canthoplasty incision. Coban YK; Kabalci SK J Craniofac Surg; 2008 Mar; 19(2):539-41. PubMed ID: 18362741 [TBL] [Abstract][Full Text] [Related]
17. [Complications of silastic implants used in orbital repair]. Laxenaire A; Lévy J; Blanchard P; Lerondeau JC; Tesnier F; Scheffer P Rev Stomatol Chir Maxillofac; 1997 Nov; 98 Suppl 1():96-9. PubMed ID: 9471710 [TBL] [Abstract][Full Text] [Related]
18. Endoscopic repair of posttraumatic enophthalmos using medial transconjunctival approach: a case report. Barone CM; Gigantelli JW J Craniomaxillofac Trauma; 1998; 4(1):22-6. PubMed ID: 11951435 [TBL] [Abstract][Full Text] [Related]
19. Treatment of orbital fractures: the case for treatment with resorbable materials. Enislidis G J Oral Maxillofac Surg; 2004 Jul; 62(7):869-72. PubMed ID: 15218568 [No Abstract] [Full Text] [Related]
20. Diagnostic and surgical approaches to orbital fractures. Della Rocca RC; Maher EA Curr Opin Ophthalmol; 1990 Oct; 1(5):527-31. PubMed ID: 10171178 [No Abstract] [Full Text] [Related] [Next] [New Search]