130 related articles for article (PubMed ID: 19079798)
1. The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities.
Taddei PJ; Borak TB; Guetersloh SB; Gersey BB; Zeitlin C; Heilbronn L; Miller J; Murakami T; Iwata Y
Radiat Meas; 2006 Oct; 4179(9-10):1227-1234. PubMed ID: 19079798
[TBL] [Abstract][Full Text] [Related]
2. The response of a spherical tissue-equivalent proportional counter to different ions having similar linear energy transfer.
Guetersloh SB; Borak TB; Taddei PJ; Zeitlin C; Heilbronn L; Miller J; Murakami T; Iwata Y
Radiat Res; 2004 Jan; 161(1):64-71. PubMed ID: 14680395
[TBL] [Abstract][Full Text] [Related]
3. Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III).
Borak TB; Doke T; Fuse T; Guetersloh S; Heilbronn L; Hara K; Moyers M; Suzuki S; Taddei P; Terasawa K; Zeitlin CJ
Radiat Res; 2004 Dec; 162(6):687-92. PubMed ID: 15548122
[TBL] [Abstract][Full Text] [Related]
4. A comparison of the measured responses of a tissue-equivalent proportional counter to high energy heavy (HZE) particles and those simulated using the Geant4 Monte Carlo code.
Taddei PJ; Zhao Z; Borak TB
Radiat Meas; 2008 Oct; 43(9-10):1498-1505. PubMed ID: 20862212
[TBL] [Abstract][Full Text] [Related]
5. The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon.
Gersey BB; Borak TB; Guetersloh SB; Zeitlin C; Miller J; Heilbronn L; Murakami T; Iwata Y
Radiat Res; 2002 Mar; 157(3):350-60. PubMed ID: 11839098
[TBL] [Abstract][Full Text] [Related]
6. The relative biological effectiveness for carbon, nitrogen, and oxygen ion beams using passive and scanning techniques evaluated with fully 3D silicon microdosimeters.
Tran LT; Bolst D; Guatelli S; Pogossov A; Petasecca M; Lerch MLF; Chartier L; Prokopovich DA; Reinhard MI; Povoli M; Kok A; Perevertaylo VL; Matsufuji N; Kanai T; Jackson M; Rosenfeld AB
Med Phys; 2018 May; 45(5):2299-2308. PubMed ID: 29572856
[TBL] [Abstract][Full Text] [Related]
7. Design and dosimetry of a facility to study health effects following exposures to fission neutrons at low dose rates for long durations.
Borak TB; Heilbronn LH; Krumland N; Weil MM
Int J Radiat Biol; 2021; 97(8):1063-1076. PubMed ID: 31687872
[TBL] [Abstract][Full Text] [Related]
8. Systematic measurement of lineal energy distributions for proton, He and Si ion beams over a wide energy range using a wall-less tissue equivalent proportional counter.
Tsuda S; Sato T; Takahashi F; Satoh D; Sasaki S; Namito Y; Iwase H; Ban S; Takada M
J Radiat Res; 2012; 53(2):264-71. PubMed ID: 22510599
[TBL] [Abstract][Full Text] [Related]
9. FLUKA capabilities for microdosimetric analysis.
Northum JD; Guetersloh SB; Braby LA
Radiat Res; 2012 Jan; 177(1):117-23. PubMed ID: 22050453
[TBL] [Abstract][Full Text] [Related]
10. Biological characterization of low-energy ions with high-energy deposition on human cells.
Saha J; Wilson P; Thieberger P; Lowenstein D; Wang M; Cucinotta FA
Radiat Res; 2014 Sep; 182(3):282-91. PubMed ID: 25098728
[TBL] [Abstract][Full Text] [Related]
11. The response of tissue-equivalent proportional counters to heavy ions.
Nikjoo H; Khvostunov IK; Cucinotta FA
Radiat Res; 2002 Apr; 157(4):435-45. PubMed ID: 11893246
[TBL] [Abstract][Full Text] [Related]
12. Measurement of microdosimetric spectra with a wall-less tissue-equivalent proportional counter for a 290 MeV/u 12C beam.
Tsuda S; Sato T; Takahashi F; Satoh D; Endo A; Sasaki S; Namito Y; Iwase H; Ban S; Takada M
Phys Med Biol; 2010 Sep; 55(17):5089-101. PubMed ID: 20702924
[TBL] [Abstract][Full Text] [Related]
13. Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles.
Rademacher SE; Borak TB; Zeitlin C; Heilbronn L; Miller J
Radiat Res; 1998 Apr; 149(4):387-95. PubMed ID: 9525504
[TBL] [Abstract][Full Text] [Related]
14. Microdosimetric measurements of a clinical proton beam with micrometer-sized solid-state detector.
Anderson SE; Furutani KM; Tran LT; Chartier L; Petasecca M; Lerch M; Prokopovich DA; Reinhard M; Perevertaylo VL; Rosenfeld AB; Herman MG; Beltran C
Med Phys; 2017 Nov; 44(11):6029-6037. PubMed ID: 28905399
[TBL] [Abstract][Full Text] [Related]
15. Microdosimetric evaluation of secondary particles in a phantom produced by carbon 290 MeV/nucleon ions at HIMAC.
Endo S; Takada M; Onizuka Y; Tanaka K; Maeda N; Ishikawa M; Miyahara N; Hayabuchi N; Shizuma K; Hoshi M
J Radiat Res; 2007 Sep; 48(5):397-406. PubMed ID: 17690533
[TBL] [Abstract][Full Text] [Related]
16. Shielding experiment of heavy-ion produced neutrons using a tissue-equivalent proportional counter.
Nunomiya T; Yonai S; Takada M; Fukumura A; Nakamura T
Radiat Prot Dosimetry; 2003; 106(3):207-18. PubMed ID: 14690321
[TBL] [Abstract][Full Text] [Related]
17. DOSIMETRIC response of a REM-500 in low energy neutron fields typical of nuclear power plants.
Aslam ; Matysiak W; Atanackovic J; Waker AJ
Health Phys; 2012 Jun; 102(6):603-13. PubMed ID: 22570919
[TBL] [Abstract][Full Text] [Related]
18. Technical Note: Effect of magnetic fields on the microdosimetry of carbon-ion beams.
Dai T; Li Q; Liu X; Dai Z; He P; Ma Y; Shen G; Chen W; Zhang H; Meng Q; Zhang X
Med Phys; 2019 Aug; 46(8):3746-3750. PubMed ID: 31148177
[TBL] [Abstract][Full Text] [Related]
19. Microdosimetry measurements characterizing the radiation fields of 300 MeV/u 12C and 185 MeV/u 7Li pencil beams stopping in water.
Martino G; Durante M; Schardt D
Phys Med Biol; 2010 Jun; 55(12):3441-9. PubMed ID: 20508316
[TBL] [Abstract][Full Text] [Related]
20. Physical and biological studies with protons and HZE particles in a NASA supported research center in radiation health.
Chatterjee A; Borak TH
Phys Med; 2001; 17 Suppl 1():59-66. PubMed ID: 11770539
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]