These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 19080976)

  • 1. Percutaneous closure of Blalock-Taussig shunts using Gianturco coils.
    Santiago JJ; Pedra CA; Arnoni D; Braga SL; Esteves CA; Sousa LC; Jatene MB; Fontes VF
    Rev Esp Cardiol; 2008 Dec; 61(12):1342-5. PubMed ID: 19080976
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Percutaneous closure of a modified Blalock-Taussig shunt using an amplatzer vascular plug.
    Rios-Méndez RE; Gamboa R; Mollón FP
    Rev Esp Cardiol; 2009 Oct; 62(10):1180-3. PubMed ID: 19793524
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wire-snare technique with distal flow control for coil occlusion of a modified Blalock-Taussig shunt.
    Limsuwan A; Sklansky MS; Kashani IA; Shaughnessy RD; Lucas VW; Rothman A
    Catheter Cardiovasc Interv; 2000 Jan; 49(1):51-4. PubMed ID: 10627366
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Systemic-to-pulmonary artery collateral vessels and surgical shunts in patients with cyanotic congenital heart disease: perioperative treatment by transcatheter embolization.
    Sharma S; Kothari SS; Krishnakumar R; Saxena A; Sharma R; Taneja K; Rajani M; Venugopal P
    AJR Am J Roentgenol; 1995 Jun; 164(6):1505-10. PubMed ID: 7754902
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Systemic-pulmonary shunts in infants and children. Early and late results.
    Lamberti JJ; Carlisle J; Waldman JD; Lodge FA; Kirkpatrick SE; George L; Mathewson JW; Turner SW; Pappelbaum SJ
    J Thorac Cardiovasc Surg; 1984 Jul; 88(1):76-81. PubMed ID: 6204171
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hybrid approach to surgical correction of tetralogy of Fallot in all patients with functioning Blalock Taussig shunts.
    Sivakumar K; Krishnan P; Pieris R; Francis E
    Catheter Cardiovasc Interv; 2007 Aug; 70(2):256-64. PubMed ID: 17503508
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter occlusion of Blalock-Taussig shunts: technical options.
    Burrows PE; Edwards TC; Benson LN
    J Vasc Interv Radiol; 1993; 4(5):673-80. PubMed ID: 8219563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous closure of a Blalock-Taussig shunt.
    Morag B; Rubinstein ZJ; Smolinsky A; Goor DA
    Cardiovasc Intervent Radiol; 1984; 7(5):218-20. PubMed ID: 6498864
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Percutaneous embolization of a Blalock-Taussig shunt in an adult].
    Piovaccari G; Marzocchi A; Marrozzini C; Picchio FM; Sanguinetti M; Magnani B
    G Ital Cardiol; 1986 Jun; 16(6):527-30. PubMed ID: 3758587
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcatheter closure of surgical shunts in patients with congenital heart disease.
    Moore JW; Ing FF; Drummond D; Berdjis F; Clapp SK; Grifka RG; Nihill MR; Mullins CE
    Am J Cardiol; 2000 Mar; 85(5):636-40. PubMed ID: 11078280
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coil embolization of a Blalock-Taussig shunt.
    Shrivastava S; Sharma S; Sanghvi S; Venugopal P
    Indian Heart J; 1993; 45(3):219-20. PubMed ID: 8314277
    [No Abstract]   [Full Text] [Related]  

  • 12. Does the modified Blalock-Taussig shunt cause growth of the contralateral pulmonary artery?
    Jahangiri M; Lincoln C; Shinebourne EA
    Ann Thorac Surg; 1999 May; 67(5):1397-9. PubMed ID: 10355419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcatheter closure of large patent ductus arteriosus (> or = 4 mm) with multiple Gianturco coils: immediate and mid-term results.
    Hijazi ZM; Geggel RL
    Heart; 1996 Dec; 76(6):536-40. PubMed ID: 9014805
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noninvasive evaluation of Blalock-Taussig shunts: determination of patency and differentiation from patent ductus arteriosus by doppler echocardiography.
    Stevenson JG; Kawabori I; Bailey WW
    Am Heart J; 1983 Nov; 106(5 Pt 1):1121-32. PubMed ID: 6637769
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coil embolization to occlude aortopulmonary collateral vessels and shunts in patients with congenital heart disease.
    Perry SB; Radtke W; Fellows KE; Keane JF; Lock JE
    J Am Coll Cardiol; 1989 Jan; 13(1):100-8. PubMed ID: 2909557
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Emergency transcatheter balloon recanalization of acutely thrombosed modified Blalock-Taussig shunts.
    Sivakumar K; Anil SR; Ravichandra M; Natarajan KU; Kamath P; Kumar RK
    Indian Heart J; 2001; 53(6):743-8. PubMed ID: 11838928
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous intervention for central shunts: new routes, new strategies.
    Cools B; Brown SC; Boshoff DE; Eyskens B; Heying R; Rega F; Meyns B; Gewillig M
    Acta Cardiol; 2017 Apr; 72(2):142-148. PubMed ID: 28597797
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcatheter closure of modified Blalock-Taussig shunt with Gianturco-Grifka Vascular Occlusion Device.
    Hoyer MH; Leon RA; Fricker FJ
    Catheter Cardiovasc Interv; 1999 Dec; 48(4):365-7. PubMed ID: 10559814
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Successful microsurgical extraction of a migrated coil in a pediatric patient after failed endovascular closure of a Blalock-Taussig shunt. Case report.
    Heuer GG; Zaghloul KA; Roberts R; Stiefel MF; Storm PB
    J Neurosurg; 2007 Feb; 106(2 Suppl):136-8. PubMed ID: 17330541
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Criterions for selection of patients for, and results of, a new technique for construction of the modified Blalock-Taussig shunt.
    Chowdhury UK; Venugopal P; Kothari SS; Saxena A; Talwar S; Subramaniam G; Singh R; Pradeep KK; Sathia S; Kumar AS
    Cardiol Young; 2006 Oct; 16(5):463-73. PubMed ID: 16984698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.