These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

646 related articles for article (PubMed ID: 19082190)

  • 21. Stir-bar sorptive extraction and thermal desorption-ion mobility spectrometry for the determination of trinitrotoluene and l,3,5-trinitro-l,3,5-triazine in water samples.
    Lokhnauth JK; Snow NH
    J Chromatogr A; 2006 Feb; 1105(1-2):33-8. PubMed ID: 16249003
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Accumulation of explosives in hair--part II: factors affecting sorption.
    Oxley JC; Smith JL; Kirschenbaum LJ; Marimganti S
    J Forensic Sci; 2007 Nov; 52(6):1291-6. PubMed ID: 18093063
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Investigating the fate of nitroaromatic (TNT) and nitramine (RDX and HMX) explosives in fractured and pristine soils.
    Douglas TA; Walsh ME; McGrath CJ; Weiss CA
    J Environ Qual; 2009; 38(6):2285-94. PubMed ID: 19875785
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Identification of explosives with two-dimensional ultraviolet resonance Raman spectroscopy.
    Comanescu G; Manka CK; Grun J; Nikitin S; Zabetakis D
    Appl Spectrosc; 2008 Aug; 62(8):833-9. PubMed ID: 18702854
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Micro-solid-phase extraction coupled to desorption electrospray ionization-high-resolution mass spectrometry for the analysis of explosives in soil.
    Bianchi F; Gregori A; Braun G; Crescenzi C; Careri M
    Anal Bioanal Chem; 2015 Jan; 407(3):931-8. PubMed ID: 25277104
    [TBL] [Abstract][Full Text] [Related]  

  • 26. In-situ detection of single particles of explosive on clothing with confocal Raman microscopy.
    Ali EM; Edwards HG; Scowen IJ
    Talanta; 2009 May; 78(3):1201-3. PubMed ID: 19269494
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Detection of Explosives Using Differential Laser-Induced Perturbation Spectroscopy with a Raman-based Probe.
    Oztekin EK; Burton DJ; Hahn DW
    Appl Spectrosc; 2016 Apr; 70(4):676-87. PubMed ID: 26865581
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Trace Detection of RDX, HMX and PETN Explosives Using a Fluorescence Spot Sensor.
    Wang C; Huang H; Bunes BR; Wu N; Xu M; Yang X; Yu L; Zang L
    Sci Rep; 2016 May; 6():25015. PubMed ID: 27146290
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Explosives removal and quantification using porous adsorbents based on poly(2-oxazoline)s with various degree of functionalization.
    Cegłowski M; Otłowski T; Gierczyk B; Smeets S; Lusina A; Hoogenboom R
    Chemosphere; 2023 Nov; 340():139807. PubMed ID: 37574087
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Low-pressure barrier discharge ion source using air as a carrier gas and its application to the analysis of drugs and explosives.
    Usmanov DT; Yu Z; Chen LC; Hiraoka K; Yamabe S
    J Mass Spectrom; 2016 Feb; 51(2):132-40. PubMed ID: 26889929
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Rapid identification and desorption mechanisms of nitrogen-based explosives by ambient micro-fabricated glow discharge plasma desorption/ionization (MFGDP) mass spectrometry.
    Tian C; Yin J; Zhao Z; Zhang Y; Duan Y
    Talanta; 2017 May; 167():75-85. PubMed ID: 28340788
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accumulation of explosives in hair.
    Oxley JC; Smith JL; Kirschenbaum LJ; Shinde KP; Marimganti S
    J Forensic Sci; 2005 Jul; 50(4):826-31. PubMed ID: 16078483
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Application of LC-QTOF/MS for the validation and determination of organic explosive residues on Ionscan® swabs.
    Suppajariyawat P; Gonzalez-Rodriguez J
    Sci Justice; 2021 Nov; 61(6):697-703. PubMed ID: 34802643
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Integration of paper spray ionization high-field asymmetric waveform ion mobility spectrometry for forensic applications.
    Tsai CW; Tipple CA; Yost RA
    Rapid Commun Mass Spectrom; 2018 Apr; 32(7):552-560. PubMed ID: 29380926
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Detection of explosives on skin using ambient ionization mass spectrometry.
    Justes DR; Talaty N; Cotte-Rodriguez I; Cooks RG
    Chem Commun (Camb); 2007 Jun; (21):2142-4. PubMed ID: 17520116
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Identification of high explosives using single-particle aerosol mass spectrometry.
    Martin AN; Farquar GR; Gard EE; Frank M; Fergenson DP
    Anal Chem; 2007 Mar; 79(5):1918-25. PubMed ID: 17249636
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determining the effects of routine fingermark detection techniques on the subsequent recovery and analysis of explosive residues on various substrates.
    King S; Benson S; Kelly T; Lennard C
    Forensic Sci Int; 2013 Dec; 233(1-3):257-64. PubMed ID: 24314527
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Detection of explosives in hair using ion mobility spectrometry.
    Oxley JC; Smith JL; Kirschenbaum LJ; Marimganti S; Vadlamannati S
    J Forensic Sci; 2008 May; 53(3):690-3. PubMed ID: 18471216
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Integrated explosive preconcentrator and electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor.
    Cizek K; Prior C; Thammakhet C; Galik M; Linker K; Tsui R; Cagan A; Wake J; La Belle J; Wang J
    Anal Chim Acta; 2010 Feb; 661(1):117-21. PubMed ID: 20113724
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use of Mass Spectrometric Vapor Analysis To Improve Canine Explosive Detection Efficiency.
    Ong TH; Mendum T; Geurtsen G; Kelley J; Ostrinskaya A; Kunz R
    Anal Chem; 2017 Jun; 89(12):6482-6490. PubMed ID: 28598144
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 33.