BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 1908415)

  • 1. Apparatus, technique and dosimetry of intraoperative electron beam therapy.
    Jones D
    Front Radiat Ther Oncol; 1991; 25():233-45. PubMed ID: 1908415
    [No Abstract]   [Full Text] [Related]  

  • 2. Surgical aspects of intraoperative electron beam therapy.
    Owens JC; Graves GM
    Front Radiat Ther Oncol; 1991; 25():224-32. PubMed ID: 1908414
    [No Abstract]   [Full Text] [Related]  

  • 3. Matching intraoperative electron-beam fields: dosimetric and clinical considerations.
    Shaw EG; Blackwell CR; McCullough EC; Gunderson LL
    Int J Radiat Oncol Biol Phys; 1987 Sep; 13(9):1303-7. PubMed ID: 3114185
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry.
    Fraass BA; Miller RW; Kinsella TJ; Sindelar WF; Harrington FS; Yeakel K; van de Geijn J; Glatstein E
    Int J Radiat Oncol Biol Phys; 1985 Jul; 11(7):1299-311. PubMed ID: 3924866
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surgical aspects of intraoperative radiation therapy.
    Merrick HW
    Front Radiat Ther Oncol; 1991; 25():209-23. PubMed ID: 1908413
    [No Abstract]   [Full Text] [Related]  

  • 6. Intraoperative electron beam therapy in the community environment.
    Wolkov HB
    Front Radiat Ther Oncol; 1991; 25():322-9; discussion 330-3. PubMed ID: 1908423
    [No Abstract]   [Full Text] [Related]  

  • 7. The dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac-18 accelerator.
    McCullough EC; Anderson JA
    Med Phys; 1982; 9(2):261-8. PubMed ID: 6806596
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implantation of iodine-125 seeds as a form of intraoperative brachytherapy.
    Sauerwein W; Müller B; Meyer-Schwickerath M; Hoederath A; Eigler FW; Busch M; Sack H
    Ann Radiol (Paris); 1989; 32(6):515-22. PubMed ID: 2517386
    [No Abstract]   [Full Text] [Related]  

  • 9. A non-docking intraoperative electron beam applicator system.
    Palta JR; Suntharalingam N
    Int J Radiat Oncol Biol Phys; 1989 Aug; 17(2):411-7. PubMed ID: 2502510
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Commissioning of beam shaper applicator for conformal intraoperative electron radiotherapy.
    Heidarloo N; Baghani HR; Aghamiri SM; Mahdavi SR; Akbari ME
    Appl Radiat Isot; 2017 May; 123():69-81. PubMed ID: 28260609
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intraoperative electron beam radiation therapy: technique, dosimetry, and dose specification: report of task force 48 of the Radiation Therapy Committee, American Association of Physicists in Medicine.
    Palta JR; Biggs PJ; Hazle JD; Huq MS; Dahl RA; Ochran TG; Soen J; Dobelbower RR; McCullough EC
    Int J Radiat Oncol Biol Phys; 1995 Oct; 33(3):725-46. PubMed ID: 7558965
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraoperative radiation therapy using a mobile electron linear accelerator: field matching for large-field electron irradiation.
    Beddar AS; Briere TM; Ouzidane M
    Phys Med Biol; 2006 Sep; 51(18):N331-7. PubMed ID: 16953035
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electron beam intraoperative radiation therapy for pediatric neoplasms.
    Haase GM; Meagher DP; McNeely LK; Daniel WE; Poole MA; Blake M; Odom LF
    Cancer; 1994 Jul; 74(2):740-7. PubMed ID: 8033056
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Intraoperative radiation therapy with high-energy electron beams].
    Takahashi M
    Gan To Kagaku Ryoho; 1986 Apr; 13(4 Pt 1):922-30. PubMed ID: 3083788
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraoperative electron beam therapy.
    Koh WJ; Russell KJ; Cain JM; Greer BE; Tamimi HK; Figge DC; Laramore GE; Griffin TW
    Radiol Med; 1990 Oct; 80(4 Suppl 1):86-7. PubMed ID: 2251425
    [No Abstract]   [Full Text] [Related]  

  • 16. [Intraoperative radiation therapy: its technological support, potentials and prospects].
    Boĭko AV; Chernichenko AV; Chissov VI; Kvasov VA; Kiseleva ES; Dar'ialova SL; Demidova LV; Rakhmanin IuA; Osipova NA; Donskova IuS; Rusakov IG; Novikova EG; Mamontov AS; Vashakhmadze LA; Reshetov IV
    Vestn Rentgenol Radiol; 1996; (2):45-8. PubMed ID: 8754122
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Energy and applicator size and shape used in over 800 intraoperative electron beam therapy fields.
    Thomas CR; McCullough EC; Gunderson LL
    Am J Clin Oncol; 1999 Apr; 22(2):147-9. PubMed ID: 10199448
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An overview: radiation sources, beam quality, dosimetry and spectroscopy in neutron capture therapy.
    Kanda K
    Strahlenther Onkol; 1989; 165(2-3):67-9. PubMed ID: 2494745
    [No Abstract]   [Full Text] [Related]  

  • 19. Shielding assessment of a mobile electron accelerator for intra-operative radiotherapy.
    Krechetov AS; Goer D; Dikeman K; Daves JL; Mills MD
    J Appl Clin Med Phys; 2010 Sep; 11(4):3151. PubMed ID: 21081870
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Intraoperative radiotherapy (IORT) at the Graz University Clinics: development and dosimetry of an applicator system].
    Leitner H; Arian-Schad K; Jüttner F; Kohek P; Hackl A; Friehs G
    Strahlenther Onkol; 1990 Mar; 166(3):207-10. PubMed ID: 2109356
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.