These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 19089099)

  • 1. Influence of the final temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy.
    Oliveira PC; Adabo GL; Ribeiro RF; da Rocha SS; Avila FA; do Valle AL
    J Appl Oral Sci; 2007 Feb; 15(1):44-8. PubMed ID: 19089099
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of mold temperature on castability of CP Ti and Ti-6Al-4V castings into phosphate bonded investment materials.
    Oliveira PC; Adabo GL; Ribeiro RF; Rocha SS
    Dent Mater; 2006 Dec; 22(12):1098-102. PubMed ID: 16423386
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Vickers hardness of cast commercially pure titanium and Ti-6Al-4V alloy submitted to heat treatments.
    da Rocha SS; Adabo GL; Henriques GE; Nóbilo MA
    Braz Dent J; 2006; 17(2):126-9. PubMed ID: 16924339
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An initial study of diffusion bonds between superplastic Ti-6Al-4V for implant dentistry applications.
    Elias KL; Daehn GS; Brantley WA; McGlumphy EA
    J Prosthet Dent; 2007 Jun; 97(6):357-65. PubMed ID: 17618918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of thermal treatments on tensile strength of commercially cast pure titanium and Ti-6Al-4V alloys.
    da Rocha SS; Adabo GL; Vaz LG; Henriques GE
    J Mater Sci Mater Med; 2005 Aug; 16(8):759-66. PubMed ID: 15965747
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.
    de Oliveira Correa G; Henriques GE; Mesquita MF; Sobrinho LC
    J Prosthet Dent; 2006 Mar; 95(3):243-8. PubMed ID: 16543023
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Superplastic forming of titanium alloy denture base].
    Okuno O; Nakano T; Hamanaka H; Miura I; Ito M; Ai M; Okada M
    Shika Zairyo Kikai; 1989 Mar; 8(2):129-36. PubMed ID: 2603084
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical properties of cast Ti-6Al-4V-XCu alloys.
    Aoki T; Okafor IC; Watanabe I; Hattori M; Oda Y; Okabe T
    J Oral Rehabil; 2004 Nov; 31(11):1109-14. PubMed ID: 15525390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.
    Contreras EF; Henriques GE; Giolo SR; Nobilo MA
    J Prosthet Dent; 2002 Nov; 88(5):467-72. PubMed ID: 12473994
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.
    Koike M; Hummel SK; Ball JD; Okabe T
    J Prosthet Dent; 2012 Jun; 107(6):393-9. PubMed ID: 22633596
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical properties and microstructures of cast Ti-Cu alloys.
    Kikuchi M; Takada Y; Kiyosue S; Yoda M; Woldu M; Cai Z; Okuno O; Okabe T
    Dent Mater; 2003 May; 19(3):174-81. PubMed ID: 12628428
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of Plasma Surface Treatment on Shear Bond Strength with Denture Base Resin in Co-Cr Alloy, Ti-6Al-4V Alloy, and CP-Ti Alloy.
    Kang H; Ji MK; Cho HS; Park SW; Yun KD; Park C; Lim HP
    J Nanosci Nanotechnol; 2020 Sep; 20(9):5771-5774. PubMed ID: 32331177
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of surface contamination on adhesive bonding of cast pure titanium and Ti-6Al-4V alloy.
    Watanabe I; Watanabe E; Yoshida K; Okabe T
    J Prosthet Dent; 1999 Mar; 81(3):270-6. PubMed ID: 10050113
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microstructures and Mechanical Properties of Laser-Sintered Commercially Pure Ti and Ti-6Al-4V Alloy for Dental Applications.
    Okazaki Y; Ishino A
    Materials (Basel); 2020 Jan; 13(3):. PubMed ID: 32013199
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Infrared gold alloy brazing on titanium and Ti-6Al-4V alloy surfaces and its application to removable prosthodontics.
    Wakabayashi N; Ai M; Iijima K; Takada Y; Okuno O
    J Prosthodont; 1999 Sep; 8(3):180-7. PubMed ID: 10740500
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laser and plasma dental soldering techniques applied to Ti-6Al-4V alloy: ultimate tensile strength and finite element analysis.
    Castro MG; Araújo CA; Menegaz GL; Silva JP; Nóbilo MA; Simamoto Júnior PC
    J Prosthet Dent; 2015 May; 113(5):460-6. PubMed ID: 25749079
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings.
    Fonseca JC; Henriques GE; Sobrinho LC; de Góes MF
    Dent Mater; 2003 Nov; 19(7):686-91. PubMed ID: 12901996
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols.
    Guilherme AS; Henriques GE; Zavanelli RA; Mesquita MF
    J Prosthet Dent; 2005 Apr; 93(4):378-85. PubMed ID: 15798689
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of thermal cycling on the bond strength of low-fusing porcelain to commercially pure titanium and titanium-aluminium-vanadium alloy.
    Tróia MG; Henriques GE; Nóbilo MA; Mesquita MF
    Dent Mater; 2003 Dec; 19(8):790-6. PubMed ID: 14511738
    [TBL] [Abstract][Full Text] [Related]  

  • 20. C.P titanium/Ti-6Al-4V joint by spark plasma welding: Microstructure and mechanical properties.
    Zahabi S; Mohammad Sharifi E; Naderi M; Ramezani M; Jamali H; Loghman Esatrki MR
    Heliyon; 2024 Mar; 10(6):e27514. PubMed ID: 38509952
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.