These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 19089282)

  • 1. Effect of cervical relining of acrylic resin copings on the accuracy of stone dies obtained using a polyether impression material.
    de Sá AT; de Freitas CA; de Sá FC; Ursi WJ; Simões TC; de Freitas MF
    J Appl Oral Sci; 2008; 16(1):7-11. PubMed ID: 19089282
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study.
    Caputi S; Varvara G
    J Prosthet Dent; 2008 Apr; 99(4):274-81. PubMed ID: 18395537
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques.
    Filho HG; Mazaro JV; Vedovatto E; Assunção WG; dos Santos PH
    J Prosthodont; 2009 Feb; 18(2):172-6. PubMed ID: 19178624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dimensional accuracy of dental casts: influence of tray material, impression material, and time.
    Thongthammachat S; Moore BK; Barco MT; Hovijitra S; Brown DT; Andres CJ
    J Prosthodont; 2002 Jun; 11(2):98-108. PubMed ID: 12087547
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An evaluation of impression techniques for multiple internal connection implant prostheses.
    Vigolo P; Fonzi F; Majzoub Z; Cordioli G
    J Prosthet Dent; 2004 Nov; 92(5):470-6. PubMed ID: 15523336
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The accuracy of dual-arch impressions: a pilot study.
    Larson TD; Nielsen MA; Brackett WW
    J Prosthet Dent; 2002 Jun; 87(6):625-7. PubMed ID: 12131884
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of dimensional accuracy of four different die materials before and after disinfection of the impression: an in vitro study.
    Nandini Y; Vinitha KB; Manvi S; Smitha M
    J Contemp Dent Pract; 2013 Jul; 14(4):668-74. PubMed ID: 24309347
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions.
    Ceyhan JA; Johnson GH; Lepe X
    J Prosthet Dent; 2003 Aug; 90(2):143-9. PubMed ID: 12886207
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determining the accuracy of stock and custom tray impression/casts.
    Millstein P; Maya A; Segura C
    J Oral Rehabil; 1998 Aug; 25(8):645-8. PubMed ID: 9781870
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of implant impressions with different impression coping types and shapes.
    Rashidan N; Alikhasi M; Samadizadeh S; Beyabanaki E; Kharazifard MJ
    Clin Implant Dent Relat Res; 2012 Apr; 14(2):218-25. PubMed ID: 19804420
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of different impression techniques on the dimensional accuracy of impressions using various elastomeric impression materials: an in vitro study.
    Singh K; Sahoo S; Prasad KD; Goel M; Singh A
    J Contemp Dent Pract; 2012 Jan; 13(1):98-106. PubMed ID: 22430701
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of impression techniques for implants. Part 1--Influence of transfer copings surface abrasion.
    Assunção WG; Cardoso A; Gomes EA; Tabata LF; dos Santos PH
    J Prosthodont; 2008 Dec; 17(8):641-7. PubMed ID: 19090889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dimensional accuracy of a new polyether impression material.
    Endo T; Finger WJ
    Quintessence Int; 2006 Jan; 37(1):47-51. PubMed ID: 16429703
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays.
    Burns J; Palmer R; Howe L; Wilson R
    J Prosthet Dent; 2003 Mar; 89(3):250-5. PubMed ID: 12644799
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Passive fit and accuracy of three dental implant impression techniques.
    Al Quran FA; Rashdan BA; Zomar AA; Weiner S
    Quintessence Int; 2012 Feb; 43(2):119-25. PubMed ID: 22257873
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of implant impression techniques.
    Assif D; Marshak B; Schmidt A
    Int J Oral Maxillofac Implants; 1996; 11(2):216-22. PubMed ID: 8666454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the precision of three implant transfer impression techniques using two elastomeric impression materials.
    Mostafa TM; Elgendy MN; Kashef NA; Halim MM
    Int J Prosthodont; 2010; 23(6):525-8. PubMed ID: 21209987
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of disinfection of custom tray materials on adhesive properties of several impression material systems.
    Thompson GA; Vermilyea SG; Agar JR
    J Prosthet Dent; 1994 Dec; 72(6):651-6. PubMed ID: 7853264
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations.
    Al-Abdullah K; Zandparsa R; Finkelman M; Hirayama H
    J Prosthet Dent; 2013 Aug; 110(2):90-100. PubMed ID: 23929370
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner.
    An S; Kim S; Choi H; Lee JH; Moon HS
    J Prosthet Dent; 2014 Nov; 112(5):1171-5. PubMed ID: 24951386
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.