353 related articles for article (PubMed ID: 19091902)
1. Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph.
van Velden FH; Kloet RW; van Berckel BN; Lammertsma AA; Boellaard R
J Nucl Med; 2009 Jan; 50(1):72-80. PubMed ID: 19091902
[TBL] [Abstract][Full Text] [Related]
2. Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods.
van Velden FH; Kloet RW; van Berckel BN; Wolfensberger SP; Lammertsma AA; Boellaard R
Phys Med Biol; 2008 Jun; 53(12):3217-30. PubMed ID: 18506070
[TBL] [Abstract][Full Text] [Related]
3. Image derived input functions for dynamic High Resolution Research Tomograph PET brain studies.
Mourik JE; van Velden FH; Lubberink M; Kloet RW; van Berckel BN; Lammertsma AA; Boellaard R
Neuroimage; 2008 Dec; 43(4):676-86. PubMed ID: 18707007
[TBL] [Abstract][Full Text] [Related]
4. Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling.
Boellaard R; van Lingen A; Lammertsma AA
J Nucl Med; 2001 May; 42(5):808-17. PubMed ID: 11337581
[TBL] [Abstract][Full Text] [Related]
5. In vivo validation of reconstruction-based resolution recovery for human brain studies.
Mourik JE; Lubberink M; van Velden FH; Kloet RW; van Berckel BN; Lammertsma AA; Boellaard R
J Cereb Blood Flow Metab; 2010 Feb; 30(2):381-9. PubMed ID: 19844240
[TBL] [Abstract][Full Text] [Related]
6. The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images.
Kalantari F; Rajabi H; Ay MR; Razavi-Ratki SK; Fard-Esfahani A; Beiki D; Eftekhari M; Fallahi B; Sadeghian L; Emami-Ardekani A
Hell J Nucl Med; 2012; 15(2):92-7. PubMed ID: 22741145
[TBL] [Abstract][Full Text] [Related]
7. Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment.
Riddell C; Carson RE; Carrasquillo JA; Libutti SK; Danforth DN; Whatley M; Bacharach SL
J Nucl Med; 2001 Sep; 42(9):1316-23. PubMed ID: 11535719
[TBL] [Abstract][Full Text] [Related]
8. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
Kalantari F; Rajabi H; Saghari M
Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
[TBL] [Abstract][Full Text] [Related]
9. Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.
Lartizien C; Kinahan PE; Swensson R; Comtat C; Lin M; Villemagne V; Trébossen R
J Nucl Med; 2003 Feb; 44(2):276-90. PubMed ID: 12571221
[TBL] [Abstract][Full Text] [Related]
10. Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT.
Brambilla M; Cannillo B; Dominietto M; Leva L; Secco C; Inglese E
Ann Nucl Med; 2005 Apr; 19(2):75-82. PubMed ID: 15909485
[TBL] [Abstract][Full Text] [Related]
11. Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies.
Reilhac A; Tomeï S; Buvat I; Michel C; Keheren F; Costes N
Neuroimage; 2008 Jan; 39(1):359-68. PubMed ID: 17920931
[TBL] [Abstract][Full Text] [Related]
12. Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals.
Cheng JC; Shoghi K; Laforest R
Med Phys; 2012 Feb; 39(2):1029-41. PubMed ID: 22320813
[TBL] [Abstract][Full Text] [Related]
13. Is iterative reconstruction an alternative to filtered backprojection in routine processing of dopamine transporter SPECT studies?
Koch W; Hamann C; Welsch J; Pöpperl G; Radau PE; Tatsch K
J Nucl Med; 2005 Nov; 46(11):1804-11. PubMed ID: 16269593
[TBL] [Abstract][Full Text] [Related]
14. Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging.
Gantet P; Payoux P; Celler A; Majorel C; Gourion D; Noll D; Esquerré JP
Med Phys; 2006 Jan; 33(1):52-60. PubMed ID: 16485409
[TBL] [Abstract][Full Text] [Related]
15. Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study.
Yokoi T; Shinohara H; Onishi H
Ann Nucl Med; 2002 Feb; 16(1):11-8. PubMed ID: 11922203
[TBL] [Abstract][Full Text] [Related]
16. Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU.
Kim KS; Ye JC
Phys Med Biol; 2011 Aug; 56(15):4991-5009. PubMed ID: 21772080
[TBL] [Abstract][Full Text] [Related]
17. Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization.
Morimoto T; Ito H; Takano A; Ikoma Y; Seki C; Okauchi T; Tanimoto K; Ando A; Shiraishi T; Yamaya T; Suhara T
Ann Nucl Med; 2006 Apr; 20(3):237-43. PubMed ID: 16715957
[TBL] [Abstract][Full Text] [Related]
18. The SRT reconstruction algorithm for semiquantification in PET imaging.
Kastis GA; Gaitanis A; Samartzis AP; Fokas AS
Med Phys; 2015 Oct; 42(10):5970-82. PubMed ID: 26429272
[TBL] [Abstract][Full Text] [Related]
19. Quantitative comparison of analytic and iterative reconstruction methods in 2- and 3-dimensional dynamic cardiac 18F-FDG PET.
Lubberink M; Boellaard R; van der Weerdt AP; Visser FC; Lammertsma AA
J Nucl Med; 2004 Dec; 45(12):2008-15. PubMed ID: 15585474
[TBL] [Abstract][Full Text] [Related]
20. OS-EM and FBP reconstructions at low count rates: effect on 3D PET studies of [11C] WAY-100635.
Bélanger MJ; Mann JJ; Parsey RV
Neuroimage; 2004 Jan; 21(1):244-50. PubMed ID: 14741662
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]