These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 19093562)

  • 1. [Theory and correction of interference fringe in static fourier transform spectrometer].
    Lin L; Ren Z; Li G
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Sep; 28(9):2067-72. PubMed ID: 19093562
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror].
    Lü JG; Liang JQ; Liang ZZ; Tian C; Qin YX
    Guang Pu Xue Yu Guang Pu Fen Xi; 2016 May; 36(5):1554-9. PubMed ID: 30001062
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [The investigation and simulation of a novel spatially modulated micro-Fourier transform spectrometer].
    Kong YM; Liang JQ; Wang B; Liang ZZ; Xu DW; Zhang J
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Apr; 29(4):1142-6. PubMed ID: 19626921
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accurate measurement and adjustment method for interference fringe direction in a scanning beam interference lithography system.
    Li Y; Jiang S; Chen X; Liu Z; Wang W; Song Y; Bayanheshig
    Opt Express; 2023 Aug; 31(17):28145-28160. PubMed ID: 37710876
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fourier transform infrared spectrometer based on an electrothermal MEMS mirror.
    Wang D; Liu H; Zhang J; Chen Q; Wang W; Zhang X; Xie H
    Appl Opt; 2018 Jul; 57(21):5956-5961. PubMed ID: 30118019
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Comparison of correction methods for nonlinear optic path difference of reflecting rotating Fourier transform spectrometer].
    Jing JJ; Zhou JS; Xiangli B; Lü QB; Wei RY
    Guang Pu Xue Yu Guang Pu Fen Xi; 2010 Jun; 30(6):1678-82. PubMed ID: 20707175
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wide-spectrum reconstruction method for a birefringence interference imaging spectrometer.
    Zhang C; Jian X
    Opt Lett; 2010 Feb; 35(3):366-8. PubMed ID: 20125723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multichannel Fourier fringe analysis as an aid to automatic phase unwrapping.
    Burton DR; Lalor MJ
    Appl Opt; 1994 May; 33(14):2939-48. PubMed ID: 20885656
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Fourier Transform Spectrometer Based on Rotating Parallel-Mirror-Pair].
    Zhao BW; Xiangli B; Cai QS; Lü QB; Zhou JS
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Nov; 35(11):3209-13. PubMed ID: 26978938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Influence of collimation system on static Fourier transform spectrometer].
    Jiang CZ; Liang JQ; Liang ZZ; Sun Q; Wang WB
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Jan; 34(1):274-8. PubMed ID: 24783575
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a compact static Fourier transform spectrometer in integrated optics based on a leaky loop structure.
    Martin B; Morand A; Benech P; Leblond G; Blaize S; Lerondel G; Royer P; Kern P; Le Coarer E
    Opt Lett; 2009 Jan; 34(2):184-6. PubMed ID: 19148249
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Stray light and bandpass correction in the spectral measurement for light emitting diodes].
    Shen HP; Pan JG; Feng HJ; Xu ZH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Jun; 29(6):1493-7. PubMed ID: 19810516
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Modeling and correction of the effect of detector lateral fringe error in the large aperture static imaging spectrometer].
    Xiangli B; Lü QB; Yuan Y; Huang M; Zhou JS; Zhang GF
    Guang Pu Xue Yu Guang Pu Fen Xi; 2012 Apr; 32(4):1137-41. PubMed ID: 22715802
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design of a static Fourier-transform spectrometer with increased field of view.
    Courtial J; Patterson BA; Harvey AR; Sibbett W; Padgett MJ
    Appl Opt; 1996 Dec; 35(34):6698-702. PubMed ID: 21151250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Spectral baseline correction by piecewise dividing in Fourier transform infrared gas analysis].
    Tang XJ; Wang J; Zhang L; Guan JF; Zhang Y; Liu JH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Feb; 33(2):334-9. PubMed ID: 23697106
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Study on uniformity of optical field in static Fourier transform spectrometer].
    Lü JG; Liang JQ; Liang ZZ; Fu JG
    Guang Pu Xue Yu Guang Pu Fen Xi; 2012 Jan; 32(1):259-63. PubMed ID: 22497172
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Study on phase correction method of spatial heterodyne spectrometer].
    Wang XQ; Ye S; Zhang LJ; Xiong W
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 May; 33(5):1424-8. PubMed ID: 23905366
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Study of in-situ measurement system for porous alumina film based on AFM and reflectometric interference spectroscopy].
    Liu C; Zhang DX; Zhang HJ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Jul; 28(7):1679-83. PubMed ID: 18844188
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Parameter discretization in two-dimensional continuous wavelet transform for fast fringe pattern analysis.
    Ma J; Wang Z; Vo M; Luu L
    Appl Opt; 2011 Dec; 50(34):6399-408. PubMed ID: 22192992
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Spectral measuring of Fourier transform spectrometer using pneumatic hydraulic servo system].
    Li Z; Wang S; Wang Q; Li F
    Guang Pu Xue Yu Guang Pu Fen Xi; 2000 Aug; 20(4):589-91. PubMed ID: 12945386
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.