These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

312 related articles for article (PubMed ID: 19098352)

  • 1. Physical evaluation of prototype high-performance anti-scatter grids: potential for improved digital radiographic image quality.
    Fetterly KA; Schueler BA
    Phys Med Biol; 2009 Jan; 54(2):N37-42. PubMed ID: 19098352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems.
    Fetterly KA; Schueler BA
    Phys Med Biol; 2007 Aug; 52(16):4863-80. PubMed ID: 17671340
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficiency of antiscatter grids for flat-detector CT.
    Kyriakou Y; Kalender W
    Phys Med Biol; 2007 Oct; 52(20):6275-93. PubMed ID: 17921585
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical note: a comparison of antiscatter grids for digital radiography.
    Court L; Yamazaki T
    Br J Radiol; 2004 Nov; 77(923):950-2. PubMed ID: 15507421
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation and testing of digital intra-oral radiographic systems.
    Doyle P; Finney L
    Radiat Prot Dosimetry; 2005; 117(1-3):313-7. PubMed ID: 16461488
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Studies of performance of antiscatter grids in digital radiography: effect on signal-to-noise ratio.
    Chan HP; Lam KL; Wu YZ
    Med Phys; 1990; 17(4):655-64. PubMed ID: 2215411
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultra-high-strip-density radiographic grids: a new antiscatter technique for mammography.
    Chan HP; Frank PH; Doi K; Iida N; Higashida Y
    Radiology; 1985 Mar; 154(3):807-15. PubMed ID: 3969487
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Grids or air gaps for scatter reduction in digital radiography: a model calculation.
    Neitzel U
    Med Phys; 1992; 19(2):475-81. PubMed ID: 1584148
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of radiographic image quality parameters obtained with the REX simulator.
    Magalhaes LA; Drexler GG; deAlmeida CE
    Radiat Prot Dosimetry; 2011 Nov; 147(4):614-8. PubMed ID: 21273198
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects.
    Cunha DM; Tomal A; Poletti ME
    Phys Med Biol; 2010 Aug; 55(15):4335-59. PubMed ID: 20647608
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors.
    Willis CE; Vinogradskiy YY; Lofton BK; White RA
    Med Phys; 2011 Jul; 38(7):4422-9. PubMed ID: 21859043
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Effects of high-strip density anti-scatter grid on image quality and radiation dose].
    Wamser G; Maier W; Aichinger H; Bohndorf K
    Rofo; 1997 Jun; 166(6):475-80. PubMed ID: 9272997
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel technique for determination of two dimensional signal-to-noise ratio improvement factor of an antiscatter grid in digital radiography.
    Nøtthellen J; Konst B; Abildgaard A
    Phys Med Biol; 2014 Aug; 59(15):4213-25. PubMed ID: 25017397
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Use of multi-grid screens in intensive care units].
    Grunert JH; Boy B; Groenewold SK; Krahn-Peters V; Hendrickx P
    Aktuelle Radiol; 1995 Sep; 5(5):293-6. PubMed ID: 7495890
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An examination of automatic exposure control regimes for two digital radiography systems.
    Marshall NW
    Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.
    Altunbas C; Kavanagh B; Alexeev T; Miften M
    Med Phys; 2017 Aug; 44(8):3952-3964. PubMed ID: 28513847
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quality assurance of computed and digital radiography systems.
    Walsh C; Gorman D; Byrne P; Larkin A; Dowling A; Malone JF
    Radiat Prot Dosimetry; 2008; 129(1-3):271-5. PubMed ID: 18319281
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparison of film-screen combinations in contrast-detail diagram and with interactive image analysis. 3: Trimodal histograms of gray scale distribution in bar groups of lead pattern images].
    Hagemann G; Eichbaum G; Stamm G
    Aktuelle Radiol; 1998 May; 8(3):151-6. PubMed ID: 9645256
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Effect of Interspaces of Anti-scatter Grid on the Image Improvement Factor].
    Saito H; Asano H; Miyake H; Nakamura H; Imai Y; Ogura I; Negishi T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2018; 74(10):1186-1193. PubMed ID: 30344216
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical evaluation of a prototype ratio 29:1 grid for adult patient cardiovascular angiography imaging conditions.
    Fetterly KA; Schueler BA; Hindal MD; Miller DL
    Phys Med Biol; 2021 Jul; 66(14):. PubMed ID: 34157690
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.