179 related articles for article (PubMed ID: 19105992)
1. Effect of severely reduced bone support on the stress field developed within the connectors of three types of cross-arch fixed partial dentures.
Manda M; Galanis C; Georgiopoulos V; Provatidis C; Koidis P
J Prosthet Dent; 2009 Jan; 101(1):54-65. PubMed ID: 19105992
[TBL] [Abstract][Full Text] [Related]
2. Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: a three-dimensional finite element analysis.
Manda M; Galanis C; Georgiopoulos V; Provatidis C; Koidis P
J Prosthet Dent; 2010 Feb; 103(2):91-100. PubMed ID: 20141813
[TBL] [Abstract][Full Text] [Related]
3. The effect of type of restoration on the stress field developed in terminal abutments with severely reduced periodontal support and coronal structure.
Stasinopoulou I; Manda M; Galanis C; Koidis P
J Prosthet Dent; 2013 Oct; 110(4):303-12. PubMed ID: 24079566
[TBL] [Abstract][Full Text] [Related]
4. Stress analysis of a cantilevered fixed partial denture with normal and reduced bone support.
Yang HS; Chung HJ; Park YJ
J Prosthet Dent; 1996 Oct; 76(4):424-30. PubMed ID: 8897301
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.
Lin CL; Wang JC; Chang WJ
Clin Oral Implants Res; 2008 Jan; 19(1):107-17. PubMed ID: 17944965
[TBL] [Abstract][Full Text] [Related]
6. Stress analysis of effects of nonrigid connectors on fixed partial dentures with pier abutments.
Oruc S; Eraslan O; Tukay HA; Atay A
J Prosthet Dent; 2008 Mar; 99(3):185-92. PubMed ID: 18319089
[TBL] [Abstract][Full Text] [Related]
7. Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response: biological-data-based finite element study.
Yoda N; Liao Z; Chen J; Sasaki K; Swain M; Li Q
J Oral Rehabil; 2016 Sep; 43(9):692-701. PubMed ID: 27224022
[TBL] [Abstract][Full Text] [Related]
8. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.
Ramakrishaniah R; Al Kheraif AA; Elsharawy MA; Alsaleh AK; Ismail Mohamed KM; Rehman IU
Dent Mater; 2015 May; 31(5):514-21. PubMed ID: 25765540
[TBL] [Abstract][Full Text] [Related]
9. Effects of cantilever design and material on stress distribution in fixed partial dentures--a finite element analysis.
Eraslan O; Sevimay M; Usumez A; Eskitascioglu G
J Oral Rehabil; 2005 Apr; 32(4):273-8. PubMed ID: 15790382
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of stress induced by implant type, number of splinted teeth, and variations in periodontal support in tooth-implant-supported fixed partial dentures: a non-linear finite element analysis.
Lin CL; Wang JC; Chang SH; Chen ST
J Periodontol; 2010 Jan; 81(1):121-30. PubMed ID: 20059424
[TBL] [Abstract][Full Text] [Related]
11. Fixed cantilever splints on teeth with normal and reduced periodontal support.
Wylie RS; Caputo AA
J Prosthet Dent; 1991 Dec; 66(6):737-42. PubMed ID: 1805021
[TBL] [Abstract][Full Text] [Related]
12. Biomechanics of cantilever fixed partial dentures in shortened dental arch therapy.
Romeed SA; Fok SL; Wilson NH
J Prosthodont; 2004 Jun; 13(2):90-100. PubMed ID: 15210004
[TBL] [Abstract][Full Text] [Related]
13. Finite element analysis of fixed partial denture replacement.
Romeed SA; Fok SL; Wilson NH
J Oral Rehabil; 2004 Dec; 31(12):1208-17. PubMed ID: 15544658
[TBL] [Abstract][Full Text] [Related]
14. Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.
Cordaro L; Ercoli C; Rossini C; Torsello F; Feng C
J Prosthet Dent; 2005 Oct; 94(4):313-20. PubMed ID: 16198167
[TBL] [Abstract][Full Text] [Related]
15. The effect of implant design on the stress distribution in a three-unit implant-supported distal cantilever fixed partial denture: a three-dimensional finite-element analysis.
Koka P; Mohapatra A; Anandapandian PA; Murugesan K; Vasanthakumar M
Indian J Dent Res; 2012; 23(2):129-34. PubMed ID: 22945697
[TBL] [Abstract][Full Text] [Related]
16. Finite element stress analysis on the effect of splinting in fixed partial dentures.
Yang HS; Lang LA; Felton DA
J Prosthet Dent; 1999 Jun; 81(6):721-8. PubMed ID: 10347362
[TBL] [Abstract][Full Text] [Related]
17. Influence of the supporting structure on stress distribution in all-ceramic FPDs.
Dittmer MP; Kohorst P; Borchers L; Stiesch M
Int J Prosthodont; 2010; 23(1):63-8. PubMed ID: 20234896
[TBL] [Abstract][Full Text] [Related]
18. The influence of the loading mode on the stress distribution on the connector region of metal-ceramic and all-ceramic fixed partial denture.
Motta AB; Pereira LC; da Cunha AR; Duda FP
Artif Organs; 2008 Apr; 32(4):283-91. PubMed ID: 18370942
[TBL] [Abstract][Full Text] [Related]
19. Methods to improve a periodontally involved terminal abutment of a cantilever fixed partial denture--a finite element stress analysis.
Wang CH; Lee HE; Wang CC; Chang HP
J Oral Rehabil; 1998 Apr; 25(4):253-7. PubMed ID: 9610851
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical behaviour of tooth-supported fixed partial dentures by 3D FEA.
Naveau A; Chesneau J; Barquins M; Pierrisnard L
Eur J Prosthodont Restor Dent; 2009 Dec; 17(4):157-63. PubMed ID: 20158056
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]