These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 1911316)

  • 1. The influence of cutaneous factors on the transcutaneous pO2 and pCO2 at various body sites.
    Takiwaki H; Nakanishi H; Shono Y; Arase S
    Br J Dermatol; 1991 Sep; 125(3):243-7. PubMed ID: 1911316
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The effect of different types of anesthetic respirators on oxygenation and ventilation in infants during short-term anesthesia. A study using transcutaneous PO2 and PCO2 monitoring].
    Scheiber G; Hess W; Marichal A
    Anaesthesist; 1994 Aug; 43(8):510-20. PubMed ID: 7978174
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of transcutaneous oxygen and carbon dioxide monitors in normal adults and critically ill patients.
    Rithalia SV; Farrow P; Doran BR
    Intensive Crit Care Nurs; 1992 Mar; 8(1):40-6. PubMed ID: 1559023
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcutaneous PO2 and PCO2 monitoring at 37 degrees C. cutaneous PO2 and PCO2.
    Rooth G; Ewald U; Caligara F
    Adv Exp Med Biol; 1987; 220():23-32. PubMed ID: 3118654
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcutaneous blood gas monitoring among neonatal intensive care units in Japan.
    Ochiai M; Kurata H; Inoue H; Ichiyama M; Fujiyoshi J; Watabe S; Hiroma T; Nakamura T; Ohga S
    Pediatr Int; 2020 Feb; 62(2):169-174. PubMed ID: 31845473
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcutaneous monitors during one-lung ventilation: are they reliable?
    Chung MR; Lichtor JL; Rangachari K; Roizen MF
    J Cardiothorac Anesth; 1988 Jun; 2(3):313-9. PubMed ID: 17171866
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a new combined transcutaneous tcPCO
    van Wijk JJ; van Weteringen W; Hoeks SE; Staals LM
    Paediatr Anaesth; 2022 Mar; 32(3):429-435. PubMed ID: 34882905
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of electrode temperature on measurements of transcutaneous carbon dioxide partial pressure and oxygen partial pressure in very low birth weight infants.
    Li BH; Zhao CL; Cao SL; Geng HL; Li JJ; Zhu M; Niu SP
    Zhongguo Dang Dai Er Ke Za Zhi; 2021 Aug; 23(8):809-813. PubMed ID: 34511170
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of transcutaneous pCO2 and pO2 in the fetus during labor.
    Schmidt S; Langner K; Dudenhausen JW; Saling E
    Arch Gynecol; 1985; 236(3):145-51. PubMed ID: 3925898
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults.
    Wimberley PD; Grønlund Pedersen K; Olsson J; Siggaard-Andersen O
    Clin Chem; 1985 Oct; 31(10):1611-5. PubMed ID: 3930089
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Demonstrating the Potential of Using Transcutaneous Oxygen and Carbon Dioxide Tensions to Assess the Risk of Pressure Injuries.
    Xue M; Wang D; Zhang Z; Cao Z; Luo Z; Zheng Y; Lu J; Zhao Q; Zhang XD
    Int J Biol Sci; 2018; 14(11):1466-1471. PubMed ID: 30262998
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-invasive continuous fetal transcutaneous pO2 and pCO2 monitoring during labor.
    Okane M; Shigemitsu S; Inaba J; Koresawa M; Kubo T; Iwasaki H
    J Perinat Med; 1989; 17(6):399-410. PubMed ID: 2517562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcutaneous oxygen and carbon dioxide levels and a clinical symptom scale for monitoring the acute asthmatic state in infants and young children.
    Wennergren G; Engström I; Bjure J
    Acta Paediatr Scand; 1986 May; 75(3):465-9. PubMed ID: 3088908
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of time courses of agreement between minutely obtained transcutaneous blood gas data and the gold standard arterial data from spontaneously breathing Asian adults, and various subgroup analyses.
    Umeda A; Ishizaka M; Tasaki M; Yamane T; Watanabe T; Inoue Y; Mochizuki T; Okada Y; Kesler S
    BMC Pulm Med; 2020 May; 20(1):151. PubMed ID: 32471394
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia.
    Nishiyama T; Nakamura S; Yamashita K
    Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcutaneous oxygen and carbon dioxide levels with iloprost administration in diabetic critical limb ischemia.
    Melillo E; Ferrari M; Balbarini A; Pedrinelli R
    Vasc Endovascular Surg; 2006; 40(4):303-11. PubMed ID: 16959724
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term transcutaneous monitoring of oxygen tension and carbon dioxide at 42 degrees C in critically ill neonates: improved performance of the tcpo2 monitor with topical metabolic inhibition.
    Fanconi S; Tschupp A; Molinari L
    Eur J Pediatr; 1996 Dec; 155(12):1043-6. PubMed ID: 8956942
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The use of a transcutaneous pO2/pCO2 combination electrode during volume therapy in a child in shock].
    Haisjackl M; Hasibeder W; Sparr H; Klaunzer S; Putz G; Kroesen G
    Anaesthesist; 1989 Aug; 38(8):431-3. PubMed ID: 2782600
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
    Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
    Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of two transcutaneous monitors for the measurement of arterial PO2 and PCO2 in neonates.
    Carter B; Hochmann M; Osborne A; Nisbet A; Campbell N
    Anaesth Intensive Care; 1995 Dec; 23(6):708-14. PubMed ID: 8669606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.