  • 21. Effects of vertebroplasty on endplate subsidence in elderly female spines.
    Nagaraja S; Awada HK; Dreher ML; Bouck JT; Gupta S
    J Neurosurg Spine; 2015 Mar; 22(3):273-82. PubMed ID: 25525963
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Percutaneous vertebroplasty for symptomatic osteoporotic vertebral compression fracture adjacent to lumbar instrumented circumferential fusion.
    Yang SC; Chen HS; Kao YH; Ma CH; Tu YK; Chung KC
    Orthopedics; 2012 Jul; 35(7):e1079-85. PubMed ID: 22784904
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Percutaneous vertebroplasty for vertebral compression fractures with intravertebral cleft: cement injection under vacuum aspiration.
    Koike Y; Takizawa K; Ogawa Y; Fujikawa A; Yoshimatsu M; Nakajima Y
    J Vasc Interv Radiol; 2011 Dec; 22(12):1721-6. PubMed ID: 21983056
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Treatment of osteoporotic fractures. A new approach by vertebroplasty and kyphoplasty].
    Fabeck L
    Rev Med Brux; 2008 Sep; 29(4):317-22. PubMed ID: 18949983
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Percutaneous vertebroplasty for vertebral fractures caused by multiple myeloma, an aggressive vertebral haemangioma and in a traumatic burst fracture].
    Muijs SP; Dijkstra PD; van Erkel AR
    Ned Tijdschr Geneeskd; 2008 Jul; 152(30):1686-93. PubMed ID: 18714523
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Vertebral endplate fractures: an indicator of the abnormal forces generated in the spine after vertebroplasty.
    Trout AT; Kallmes DF; Layton KF; Thielen KR; Hentz JG
    J Bone Miner Res; 2006 Nov; 21(11):1797-802. PubMed ID: 17002575
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: review of the literature].
    Hendrikse CA; Kalmijn S; Voormolen MH; Verhaar HJ; Mali WP
    Ned Tijdschr Geneeskd; 2003 Aug; 147(32):1553-9. PubMed ID: 12942846
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prophylactic vertebroplasty may reduce the risk of adjacent intact vertebra from fatigue injury: an ex vivo biomechanical study.
    Chiang CK; Wang YH; Yang CY; Yang BD; Wang JL
    Spine (Phila Pa 1976); 2009 Feb; 34(4):356-64. PubMed ID: 19214094
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Decompressed percutaneous vertebroplasty: a secured bone cement delivery procedure for vertebral augmentation in osteoporotic compression fractures.
    Chu W; Tsuei YC; Liao PH; Lin JH; Chou WH; Chu WC; Young ST
    Injury; 2013 Jun; 44(6):813-8. PubMed ID: 23199757
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Vertebral reinforcement by means of kyphoplasty in the treatment of non-osteoporotic thoraco-lumbar fractures. Study of 40 cases and review of the literature].
    Arregui R; Martínez-Quiñones JV; Aso-Escario J; Aso-Vizan J
    Neurocirugia (Astur); 2008 Dec; 19(6):537-50. PubMed ID: 19112547
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intradural cement leakage: a rare complication of percutaneous vertebroplasty.
    Sabuncuoğlu H; Dinçer D; Güçlü B; Erdoğan E; Hatipoğlu HG; Ozdoğan S; Timurkaynak E
    Acta Neurochir (Wien); 2008 Aug; 150(8):811-5. PubMed ID: 18509588
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical assessment of stability in the metastatic spine following percutaneous vertebroplasty: effects of cement distribution patterns and volume.
    Tschirhart CE; Roth SE; Whyne CM
    J Biomech; 2005 Aug; 38(8):1582-90. PubMed ID: 15958214
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Prophylactic vertebroplasty can decrease the fracture risk of adjacent vertebrae: an in vitro cadaveric study.
    Aquarius R; Homminga J; Hosman AJ; Verdonschot N; Tanck E
    Med Eng Phys; 2014 Jul; 36(7):944-8. PubMed ID: 24736018
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanical effects of unipedicular vertebroplasty on intact vertebrae.
    Higgins KB; Harten RD; Langrana NA; Reiter MF
    Spine (Phila Pa 1976); 2003 Jul; 28(14):1540-7; discussion 1548. PubMed ID: 12865841
    [TBL] [Abstract][Full Text] [Related]  

  • 35. New vertebral fractures after percutaneous vertebroplasty for painful osteoporotic vertebral compression fractures: a clustered analysis and the relevance of intradiskal cement leakage.
    Nieuwenhuijse MJ; Putter H; van Erkel AR; Dijkstra PD
    Radiology; 2013 Mar; 266(3):862-70. PubMed ID: 23204545
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Vertebroplasty: magnetic resonance findings related to cement leakage risk.
    Koh YH; Han D; Cha JH; Seong CK; Kim J; Choi YH
    Acta Radiol; 2007 Apr; 48(3):315-20. PubMed ID: 17453503
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Role of cementoplasty in the management of compression vertebral body fractures.
    Hamady M; Sheard S
    Postgrad Med J; 2009 Jun; 85(1004):293-8. PubMed ID: 19528303
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cement leakage in percutaneous vertebroplasty: effect of preinjection gelfoam embolization.
    Bhatia C; Barzilay Y; Krishna M; Friesem T; Pollock R
    Spine (Phila Pa 1976); 2006 Apr; 31(8):915-9. PubMed ID: 16622381
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Temperature measurement during polymerization of bone cement in percutaneous vertebroplasty: an in vivo study in humans.
    Anselmetti GC; Manca A; Kanika K; Murphy K; Eminefendic H; Masala S; Regge D
    Cardiovasc Intervent Radiol; 2009 May; 32(3):491-8. PubMed ID: 19280257
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Treatment of painful osteoporotic or traumatic vertebral compression fractures by percutaneous vertebral augmentation procedures: a nonrandomized comparison between vertebroplasty and kyphoplasty.
    De Negri P; Tirri T; Paternoster G; Modano P
    Clin J Pain; 2007 Jun; 23(5):425-30. PubMed ID: 17515741
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]