201 related articles for article (PubMed ID: 19124107)
1. Reducing the number of reader interpretations in MRMC studies.
Obuchowski NA
Acad Radiol; 2009 Feb; 16(2):209-17. PubMed ID: 19124107
[TBL] [Abstract][Full Text] [Related]
2. A permutation test for comparing ROC curves in multireader studies a multi-reader ROC, permutation test.
Bandos AI; Rockette HE; Gur D
Acad Radiol; 2006 Apr; 13(4):414-20. PubMed ID: 16554220
[TBL] [Abstract][Full Text] [Related]
3. Prediction accuracy of a sample-size estimation method for ROC studies.
Chakraborty DP
Acad Radiol; 2010 May; 17(5):628-38. PubMed ID: 20380980
[TBL] [Abstract][Full Text] [Related]
4. Reader variability in mammography and its implications for expected utility over the population of readers and cases.
Wagner RF; Beam CA; Beiden SV
Med Decis Making; 2004; 24(6):561-72. PubMed ID: 15534338
[TBL] [Abstract][Full Text] [Related]
5. Reader studies for validation of CAD systems.
Gallas BD; Brown DG
Neural Netw; 2008; 21(2-3):387-97. PubMed ID: 18215501
[TBL] [Abstract][Full Text] [Related]
6. Analysis of location specific observer performance data: validated extensions of the jackknife free-response (JAFROC) method.
Chakraborty DP
Acad Radiol; 2006 Oct; 13(10):1187-93. PubMed ID: 16979067
[TBL] [Abstract][Full Text] [Related]
7. One-shot estimate of MRMC variance: AUC.
Gallas BD
Acad Radiol; 2006 Mar; 13(3):353-62. PubMed ID: 16488848
[TBL] [Abstract][Full Text] [Related]
8. Perceptually based FROC analysis.
Arora R; Kundel HL; Beam CA
Acad Radiol; 2005 Dec; 12(12):1567-74. PubMed ID: 16321746
[TBL] [Abstract][Full Text] [Related]
9. Reliability studies of diagnostic tests are not using enough observers for robust estimation of interobserver agreement: a simulation study.
Sadatsafavi M; Najafzadeh M; Lynd L; Marra C
J Clin Epidemiol; 2008 Jul; 61(7):722-7. PubMed ID: 18486446
[TBL] [Abstract][Full Text] [Related]
10. Incorporating utility-weights when comparing two diagnostic systems: a preliminary assessment.
Bandos AI; Rockette HE; Gur D
Acad Radiol; 2005 Oct; 12(10):1293-300. PubMed ID: 16179206
[TBL] [Abstract][Full Text] [Related]
11. Hierarchical models for ROC curve summary measures: design and analysis of multi-reader, multi-modality studies of medical tests.
Wang F; Gatsonis CA
Stat Med; 2008 Jan; 27(2):243-56. PubMed ID: 17340598
[TBL] [Abstract][Full Text] [Related]
12. Optimization of restricted ROC surfaces in three-class classification tasks.
Edwards DC; Metz CE
IEEE Trans Med Imaging; 2007 Oct; 26(10):1345-56. PubMed ID: 17948725
[TBL] [Abstract][Full Text] [Related]
13. Statistical methods for MRMC ROC studies.
Skaron A; Li K; Zhou XH
Acad Radiol; 2012 Dec; 19(12):1499-507. PubMed ID: 23122569
[TBL] [Abstract][Full Text] [Related]
14. Flexible image evaluation: iPad versus secondary-class monitors for review of MR spinal emergency cases, a comparative study.
McNulty JP; Ryan JT; Evanoff MG; Rainford LA
Acad Radiol; 2012 Aug; 19(8):1023-8. PubMed ID: 22503894
[TBL] [Abstract][Full Text] [Related]
15. The "differential diagnosis" for multiple diseases: comparison with the binary-truth state experiment in two empirical studies.
Obuchowski NA; Applegate KE; Goske MJ; Arheart KL; Myers MT; Morrison S
Acad Radiol; 2001 Oct; 8(10):947-54. PubMed ID: 11699847
[TBL] [Abstract][Full Text] [Related]
16. Application of computer-aided diagnosis (CAD) in MR-mammography (MRM): do we really need whole lesion time curve distribution analysis?
Baltzer PA; Renz DM; Kullnig PE; Gajda M; Camara O; Kaiser WA
Acad Radiol; 2009 Apr; 16(4):435-42. PubMed ID: 19268855
[TBL] [Abstract][Full Text] [Related]
17. Assessment of medical imaging systems and computer aids: a tutorial review.
Wagner RF; Metz CE; Campbell G
Acad Radiol; 2007 Jun; 14(6):723-48. PubMed ID: 17502262
[TBL] [Abstract][Full Text] [Related]
18. Assessment of the internal craniocervical ligaments with a new magnetic resonance imaging sequence: three-dimensional turbo spin echo with variable flip-angle distribution (SPACE).
Baumert B; Wörtler K; Steffinger D; Schmidt GP; Reiser MF; Baur-Melnyk A
Magn Reson Imaging; 2009 Sep; 27(7):954-60. PubMed ID: 19282121
[TBL] [Abstract][Full Text] [Related]
19. Multireader receiver operating characteristic studies: a comparison of study designs.
Obuchowski NA
Acad Radiol; 1995 Aug; 2(8):709-16. PubMed ID: 9419629
[TBL] [Abstract][Full Text] [Related]
20. Hippocampal MRI volumetry at 3 Tesla: reliability and practical guidance.
Jeukens CR; Vlooswijk MC; Majoie HJ; de Krom MC; Aldenkamp AP; Hofman PA; Jansen JF; Backes WH
Invest Radiol; 2009 Sep; 44(9):509-17. PubMed ID: 19692839
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]