These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 19124435)

  • 1. New techniques for assessment of vascular function.
    Smith RD; Levy PJ
    Ther Adv Cardiovasc Dis; 2008 Oct; 2(5):373-85. PubMed ID: 19124435
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of noninvasive hemodynamics in hypertension management.
    Sanford T; Treister N; Peters C
    Am J Hypertens; 2005 Feb; 18(2 Pt 2):87S-91S. PubMed ID: 15752938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hypertension as a hemodynamic disease: the role of impedance cardiography in diagnostic, prognostic, and therapeutic decision making.
    Ventura HO; Taler SJ; Strobeck JE
    Am J Hypertens; 2005 Feb; 18(2 Pt 2):26S-43S. PubMed ID: 15752931
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [New noninvasive methods of cardiovascular system function assessment].
    Guzik P; Gielerak G
    Pol Merkur Lekarski; 2005 Nov; 19(113):681-5. PubMed ID: 16498812
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transthoracic impedance cardiography: a noninvasive method of hemodynamic assessment.
    Bayram M; Yancy CW
    Heart Fail Clin; 2009 Apr; 5(2):161-8. PubMed ID: 19249685
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The role of noninvasive hemodynamic monitoring in the evaluation and treatment of hypertension.
    Ferrario CM; Basile J; Bestermann W; Frohlich E; Houston M; Lackland DT; Smith RD; Wise DL
    Ther Adv Cardiovasc Dis; 2007 Dec; 1(2):113-8. PubMed ID: 19124400
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Central blood pressure and hypertension: role in cardiovascular risk assessment.
    Safar ME; Jankowski P
    Clin Sci (Lond); 2009 Feb; 116(4):273-82. PubMed ID: 19138169
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A century of indirect blood pressure measurement. Back to basics.
    Cushman WC
    Arch Intern Med; 1996 Sep; 156(17):1922-3. PubMed ID: 8823145
    [No Abstract]   [Full Text] [Related]  

  • 9. Loose cuff hypertension.
    Taleyarkhan PR; Geddes LA; Kemeny AE; Vitter JS
    Cardiovasc Eng; 2009 Sep; 9(3):113-8. PubMed ID: 19662531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Brachial versus central blood pressure and vascular stiffness].
    Frimodt-Møller M; Hansen TW; Rasmussen SL
    Ugeskr Laeger; 2009 Jun; 171(24):2004-7. PubMed ID: 19523362
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Impedance cardiography - a modern tool for monitoring therapy of cardiovascular diseases].
    Krzesiński P; Gielerak G; Kowal J
    Kardiol Pol; 2009 Jan; 67(1):65-71. PubMed ID: 19253194
    [No Abstract]   [Full Text] [Related]  

  • 12. Systemic arterial blood pressure and its relevance to optometric practice.
    Terry JE; Schoessler JP
    J Am Optom Assoc; 1976 Jan; 47(1):48-52. PubMed ID: 1027761
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Level of blood pressure control in a hypertensive population when measurements are performed outside the clinical setting.
    Félix-Redondo FJ; Fernández-Bergés D; Espinosa-Garcia J; Pozuelos-Estrada J; Molina-Martínez LM; Pérez-Castán JF; Ríos-Rivera J; Valiente-Rubio JI; Gómez-de-la-Cámara A; Rodríguez-Pascual N
    Cardiol J; 2009; 16(1):57-67. PubMed ID: 19130417
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Urgent need to address quality control issues of out-of-office blood pressure measurement and patient risk assessment.
    Hedner T; Kjeldsen SE; Narkiewicz K; Oparil S
    Blood Press; 2008; 17(1):5-6. PubMed ID: 18568686
    [No Abstract]   [Full Text] [Related]  

  • 15. Overview of the history of pediatric blood pressure assessment and hypertension: an epidemiologic perspective.
    Labarthe DR
    Blood Press Monit; 1999; 4(3-4):197-203. PubMed ID: 10490878
    [No Abstract]   [Full Text] [Related]  

  • 16. [Blood pressure measurement].
    Bang LE; Wiinberg N
    Ugeskr Laeger; 2009 Jun; 171(24):2001-4. PubMed ID: 19523361
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The arterial pulse wave and vascular compliance.
    Noon JP
    Prog Cardiovasc Nurs; 2009 Jun; 24(2):53-8. PubMed ID: 19523158
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Office blood pressure measurement with electronic devices: has the time come?
    Stergiou GS
    Am J Hypertens; 2008 Mar; 21(3):246. PubMed ID: 18311123
    [No Abstract]   [Full Text] [Related]  

  • 19. Differences in blood pressure values obtained with automated and manual methods in medical inpatients.
    Bern L; Brandt M; Mbelu N; Asonye U; Fisher T; Shaver Y; Serrill C
    Medsurg Nurs; 2007 Dec; 16(6):356-61; quiz 362. PubMed ID: 18390254
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of sphygmomanometers at pharmacies.
    Erdem DG; Erdem E; Dilek M; Aydogdu T; Selim N; Demiray F; Sari A; Akpolat T
    Kidney Blood Press Res; 2009; 32(4):231-4. PubMed ID: 19622898
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.