These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

79 related articles for article (PubMed ID: 1913044)

  • 1. Dosimetric accuracy at low monitor unit settings.
    Das IJ; Kase KR; Tello VM
    Br J Radiol; 1991 Sep; 64(765):808-11. PubMed ID: 1913044
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quality assurance of the dose delivered by small radiation segments.
    Hansen VN; Evans PM; Budgell GJ; Mott JH; Williams PC; Brugmans MJ; Wittkämper FW; Mijnheer BJ; Brown K
    Phys Med Biol; 1998 Sep; 43(9):2665-75. PubMed ID: 9755953
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.
    Das IJ; Harrington JC; Akber SF; Tomer AF; Murray JC; Cheng CW
    Med Phys; 1994 Jun; 21(6):821-6. PubMed ID: 7935220
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Dosimetric characteristics of the bremsstrahlung beam from the LUE-15M medical linear electron accelerator].
    Vatnitskiĭ SM; Ermakov IA; Puzanov VP; Sinitsyn RV; Cherviakov AM
    Med Radiol (Mosk); 1983 Oct; 28(10):43-9. PubMed ID: 6415359
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric accuracy of a dual photon energy linac at low monitor setting for various pulse repetition frequencies.
    Sharma AK; Supe SS; Anantha N; Subbarangaiah K
    Med Dosim; 1994; 19(1):47-9. PubMed ID: 8003207
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Hyperfractionation--a new challenge for medical electron linear accelerators?].
    Jensen JM; Ihnen E; Glaser T; Hillenberg HJ; Kohr P; Thoms M
    Strahlenther Onkol; 1990 Jun; 166(6):415-9. PubMed ID: 2363104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical Note: FLASH radiotherapy monitor chamber signal conditioning.
    Snyder M; Vadas J; Musselwhite J; Halford R; Wilson G; Stevens C; Yan D
    Med Phys; 2021 Feb; 48(2):791-795. PubMed ID: 33296516
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A dose verification method using a monitor unit matrix for dynamic IMRT on Varian linear accelerators.
    Chen X; Yue NJ; Chen W; Saw CB; Heron DE; Stefanik D; Antemann R; Huq MS
    Phys Med Biol; 2005 Dec; 50(23):5641-52. PubMed ID: 16306658
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On comparing the quality of head and neck IMRT plans delivered with two different linear accelerator manufacturers.
    Basran PS; Balogh J; Poon I; MacKenzie R; Chan T
    Med Dosim; 2011; 36(1):75-80. PubMed ID: 20346644
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of pulsed IMRT and VMAT for re-irradiation treatments: dosimetric and delivery feasibilities.
    Lin MH; Price RA; Li J; Kang S; Li J; Ma CM
    Phys Med Biol; 2013 Nov; 58(22):8179-96. PubMed ID: 24200917
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetry characteristics of large wedges for 4- and 6-MV x rays.
    Wu A; Zwicker RD; Krasin F; Sternick ES
    Med Phys; 1984; 11(2):186-8. PubMed ID: 6427569
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Potential hazard due to induced radioactivity secondary to radiotherapy: the report of task group 136 of the American Association of Physicists in Medicine.
    Thomadsen B; Nath R; Bateman FB; Farr J; Glisson C; Islam MK; LaFrance T; Moore ME; George Xu X; Yudelev M
    Health Phys; 2014 Nov; 107(5):442-60. PubMed ID: 25271934
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the veridose QC phantom.
    Meigooni AS; Myron G; Sowards KT
    Med Dosim; 2003; 28(1):49-54. PubMed ID: 12747620
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-term dosimetric stability of multiple TomoTherapy delivery systems.
    Smilowitz JB; Dunkerley D; Hill PM; Yadav P; Geurts MW
    J Appl Clin Med Phys; 2017 May; 18(3):137-143. PubMed ID: 28464517
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A linear accelerator monitor unit totalizer.
    Pillar DG; Gillin MT; Kline RW; Grimm DF
    Med Phys; 1983; 10(6):895-6. PubMed ID: 6419035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo simulation of the photon beam characteristics from medical linear accelerators.
    Kim HK; Han SJ; Kim JL; Kim BH; Chang SY; Lee JK
    Radiat Prot Dosimetry; 2006; 119(1-4):510-3. PubMed ID: 16644954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric characteristics of the Elekta Beam Modulator.
    Patel I; Glendinning AG; Kirby MC
    Phys Med Biol; 2005 Dec; 50(23):5479-92. PubMed ID: 16306646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Computer-assisted dosimetry system for the monitor calibration of accelerators].
    Seifert H; Licht N; Leetz HK
    Strahlenther Onkol; 1994 Aug; 170(8):471-8. PubMed ID: 8085214
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Neutron dose rate evaluation for medical linear accelerators.
    Facure A; Falcão RC; Da Silva AX; Crispim VR
    Radiat Prot Dosimetry; 2004; 111(1):101-3. PubMed ID: 15367778
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An analysis of discrepancies encountered by the AAPM radiological physics center.
    Gagnon WF; Berkley LW; Kennedy P; Hanson WF; Shalek RJ
    Med Phys; 1978; 5(6):556-60. PubMed ID: 104139
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.