These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
540 related articles for article (PubMed ID: 19132850)
1. Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time? Mazze RS; Strock E; Borgman S; Wesley D; Stout P; Racchini J Diabetes Technol Ther; 2009 Jan; 11(1):11-8. PubMed ID: 19132850 [TBL] [Abstract][Full Text] [Related]
2. New features and performance of a next-generation SEVEN-day continuous glucose monitoring system with short lag time. Bailey T; Zisser H; Chang A Diabetes Technol Ther; 2009 Dec; 11(12):749-55. PubMed ID: 20001675 [TBL] [Abstract][Full Text] [Related]
3. Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems. Garg SK; Smith J; Beatson C; Lopez-Baca B; Voelmle M; Gottlieb PA Diabetes Technol Ther; 2009 Feb; 11(2):65-72. PubMed ID: 19243265 [TBL] [Abstract][Full Text] [Related]
4. The accuracy and efficacy of real-time continuous glucose monitoring sensor in Chinese diabetes patients: a multicenter study. Zhou J; Lv X; Mu Y; Wang X; Li J; Zhang X; Wu J; Bao Y; Jia W Diabetes Technol Ther; 2012 Aug; 14(8):710-8. PubMed ID: 22853722 [TBL] [Abstract][Full Text] [Related]
6. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. McGarraugh G; Bergenstal R Diabetes Technol Ther; 2009 Mar; 11(3):145-50. PubMed ID: 19216686 [TBL] [Abstract][Full Text] [Related]
7. A new-generation continuous glucose monitoring system: improved accuracy and reliability compared with a previous-generation system. Christiansen M; Bailey T; Watkins E; Liljenquist D; Price D; Nakamura K; Boock R; Peyser T Diabetes Technol Ther; 2013 Oct; 15(10):881-8. PubMed ID: 23777402 [TBL] [Abstract][Full Text] [Related]
8. Retrofitting of continuous glucose monitoring traces allows more accurate assessment of glucose control in outpatient studies. Del Favero S; Facchinetti A; Sparacino G; Cobelli C; Diabetes Technol Ther; 2015 May; 17(5):355-63. PubMed ID: 25671379 [TBL] [Abstract][Full Text] [Related]
9. Accuracy assessment of online glucose monitoring by a subcutaneous enzymatic glucose sensor during exercise in patients with type 1 diabetes treated by continuous subcutaneous insulin infusion. Radermecker RP; Fayolle C; Brun JF; Bringer J; Renard E Diabetes Metab; 2013 May; 39(3):258-62. PubMed ID: 23522730 [TBL] [Abstract][Full Text] [Related]
10. Accuracy evaluation of a new real-time continuous glucose monitoring algorithm in hypoglycemia. Mahmoudi Z; Jensen MH; Dencker Johansen M; Christensen TF; Tarnow L; Christiansen JS; Hejlesen O Diabetes Technol Ther; 2014 Oct; 16(10):667-78. PubMed ID: 24918271 [TBL] [Abstract][Full Text] [Related]
11. Comparison of the clinical information provided by the FreeStyle Navigator continuous interstitial glucose monitor versus traditional blood glucose readings. McGarraugh GV; Clarke WL; Kovatchev BP Diabetes Technol Ther; 2010 May; 12(5):365-71. PubMed ID: 20388046 [TBL] [Abstract][Full Text] [Related]
13. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Garg S; Zisser H; Schwartz S; Bailey T; Kaplan R; Ellis S; Jovanovic L Diabetes Care; 2006 Jan; 29(1):44-50. PubMed ID: 16373894 [TBL] [Abstract][Full Text] [Related]
14. Optical coherence tomography-based continuous noninvasive glucose monitoring in patients with diabetes. Gabbay RA; Sivarajah S Diabetes Technol Ther; 2008 Jun; 10(3):188-93. PubMed ID: 18473692 [TBL] [Abstract][Full Text] [Related]
15. The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Mastrototaro J; Shin J; Marcus A; Sulur G; Diabetes Technol Ther; 2008 Oct; 10(5):385-90. PubMed ID: 18715215 [TBL] [Abstract][Full Text] [Related]
16. Time lag characterization of two continuous glucose monitoring systems. Garg SK; Voelmle M; Gottlieb PA Diabetes Res Clin Pract; 2010 Mar; 87(3):348-53. PubMed ID: 20022127 [TBL] [Abstract][Full Text] [Related]
17. A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II. Christiansen MP; Klaff LJ; Brazg R; Chang AR; Levy CJ; Lam D; Denham DS; Atiee G; Bode BW; Walters SJ; Kelley L; Bailey TS Diabetes Technol Ther; 2018 Mar; 20(3):197-206. PubMed ID: 29381090 [TBL] [Abstract][Full Text] [Related]
18. Accuracy of two continuous glucose monitoring systems: a head-to-head comparison under clinical research centre and daily life conditions. Kropff J; Bruttomesso D; Doll W; Farret A; Galasso S; Luijf YM; Mader JK; Place J; Boscari F; Pieber TR; Renard E; DeVries JH Diabetes Obes Metab; 2015 Apr; 17(4):343-9. PubMed ID: 25132320 [TBL] [Abstract][Full Text] [Related]
19. Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies. Laffel L Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S223-33. PubMed ID: 26784126 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of the Enlite 6-day glucose sensor with guardian and Veo calibration algorithms. Keenan DB; Mastrototaro JJ; Zisser H; Cooper KA; Raghavendhar G; Lee SW; Yusi J; Bailey TS; Brazg RL; Shah RV Diabetes Technol Ther; 2012 Mar; 14(3):225-31. PubMed ID: 22145851 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]