BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

634 related articles for article (PubMed ID: 19133083)

  • 21. Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel-titanium instruments.
    Vieira EP; França EC; Martins RC; Buono VT; Bahia MG
    Int Endod J; 2008 Feb; 41(2):163-72. PubMed ID: 18005043
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of different types of automated devices on the shaping ability of rotary nickel-titanium FlexMaster instruments.
    Schäfer E; Erler M; Dammaschke T
    Int Endod J; 2005 Sep; 38(9):627-36. PubMed ID: 16104976
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Influence of cross-sectional design and dimension on mechanical behavior of nickel-titanium instruments under torsion and bending: a numerical analysis.
    Zhang EW; Cheung GS; Zheng YF
    J Endod; 2010 Aug; 36(8):1394-8. PubMed ID: 20647104
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments.
    Lopes HP; Ferreira AA; Elias CN; Moreira EJ; de Oliveira JC; Siqueira JF
    J Endod; 2009 Jul; 35(7):1013-6. PubMed ID: 19567325
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.
    Grande NM; Plotino G; Pecci R; Bedini R; Malagnino VA; Somma F
    Int Endod J; 2006 Oct; 39(10):755-63. PubMed ID: 16948660
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals.
    Ayar LR; Love RM
    Int Endod J; 2004 Sep; 37(9):593-601. PubMed ID: 15317562
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparison of the shaping effects of 5 nickel-titanium rotary instruments in simulated S-shaped canals.
    Ersev H; Yilmaz B; Ciftçioğlu E; Ozkarsli SF
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 May; 109(5):e86-93. PubMed ID: 20416526
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.
    Alapati SB; Brantley WA; Iijima M; Clark WA; Kovarik L; Buie C; Liu J; Ben Johnson W
    J Endod; 2009 Nov; 35(11):1589-93. PubMed ID: 19840654
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.
    Inan U; Gonulol N
    J Endod; 2009 Oct; 35(10):1396-9. PubMed ID: 19801238
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments.
    Yahata Y; Yoneyama T; Hayashi Y; Ebihara A; Doi H; Hanawa T; Suda H
    Int Endod J; 2009 Jul; 42(7):621-6. PubMed ID: 19467049
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile.
    Berutti E; Chiandussi G; Gaviglio I; Ibba A
    J Endod; 2003 Jan; 29(1):15-9. PubMed ID: 12540212
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis.
    Kim HC; Cheung GS; Lee CJ; Kim BM; Park JK; Kang SI
    J Endod; 2008 Jun; 34(6):743-7. PubMed ID: 18498904
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals.
    Schäfer E; Vlassis M
    Int Endod J; 2004 Apr; 37(4):229-38. PubMed ID: 15056349
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Cyclic fatigue testing of nickel-titanium endodontic instruments.
    Pruett JP; Clement DJ; Carnes DL
    J Endod; 1997 Feb; 23(2):77-85. PubMed ID: 9220735
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A review of cyclic fatigue testing of nickel-titanium rotary instruments.
    Plotino G; Grande NM; Cordaro M; Testarelli L; Gambarini G
    J Endod; 2009 Nov; 35(11):1469-76. PubMed ID: 19840633
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Shaping ability of progressive versus constant taper instruments in simulated root canals.
    Yang GB; Zhou XD; Zhang H; Wu HK
    Int Endod J; 2006 Oct; 39(10):791-9. PubMed ID: 16948665
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effect of argon and nitrogen ion implantation on nickel-titanium rotary instruments.
    Wolle CF; Vasconcellos MA; Hinrichs R; Becker AN; Barletta FB
    J Endod; 2009 Nov; 35(11):1558-62. PubMed ID: 19840647
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of the geometry of curved artificial canals on the fracture of rotary nickel-titanium instruments subjected to cyclic fatigue tests.
    Lopes HP; Vieira MV; Elias CN; Gonçalves LS; Siqueira JF; Moreira EJ; Vieira VT; Souza LC
    J Endod; 2013 May; 39(5):704-7. PubMed ID: 23611396
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparative analysis of torsional and bending behavior through finite-element models of 5 Ni-Ti endodontic instruments.
    Arbab-Chirani R; Chevalier V; Arbab-Chirani S; Calloch S
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jan; 111(1):115-21. PubMed ID: 21176826
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use.
    Brantley WA; Svec TA; Iijima M; Powers JM; Grentzer TH
    J Endod; 2002 Nov; 28(11):774-8. PubMed ID: 12470023
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 32.