BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 19133768)

  • 21. Polymeric membrane electrodes with improved fluoride selectivity and lifetime based on Zr(IV)- and Al(III)-tetraphenylporphyrin derivatives.
    Pietrzak M; Meyerhoff ME; Malinowska E
    Anal Chim Acta; 2007 Jul; 596(2):201-9. PubMed ID: 17631098
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of nonionic surfactants on the potentiometric response of ion-selective polymeric membrane electrodes designed for blood electrolyte measurements.
    Malinowska E; Meyerhoff ME
    Anal Chem; 1998 Apr; 70(8):1477-88. PubMed ID: 9569759
    [TBL] [Abstract][Full Text] [Related]  

  • 23. 2,6-bis-methylsulfanyl-[1,3,5]thiadiazine-4-thione as a Ag+-selective ionophore.
    Mahajan RK; Sood P; Mahajan MP; Singh P
    Anal Sci; 2004 Oct; 20(10):1423-6. PubMed ID: 15524195
    [TBL] [Abstract][Full Text] [Related]  

  • 24. New polymeric membrane cadmium(II)-selective electrodes using tripodal amine based ionophores.
    Khamjumphol U; Watchasit S; Suksai C; Janrungroatsakul W; Boonchiangma S; Tuntulani T; Ngeontae W
    Anal Chim Acta; 2011 Oct; 704(1-2):73-86. PubMed ID: 21907024
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Polymeric membrane electrodes for monohydrogen phosphate and sulfate.
    Fibbioli M; Berger M; Schmidtchen FP; Pretsch E
    Anal Chem; 2000 Jan; 72(1):156-60. PubMed ID: 10655648
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Electroanalytical and biocompatibility studies on carboxylated poly(vinyl chloride) membranes for microfabricated array sensors.
    Cosofret VV; Erdösy M; Buck RP; Kao WJ; Anderson JM; Lindner E; Neuman MR
    Analyst; 1994 Nov; 119(11):2283-92. PubMed ID: 7872483
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Fluorinated tripodal receptors for potentiometric chloride detection in biological fluids.
    Pankratova N; Cuartero M; Jowett LA; Howe ENW; Gale PA; Bakker E; Crespo GA
    Biosens Bioelectron; 2018 Jan; 99():70-76. PubMed ID: 28738230
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fabrication of a highly selective cadmium (II) sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore.
    Ghaemi A; Tavakkoli H; Mombeni T
    Mater Sci Eng C Mater Biol Appl; 2014 May; 38():186-91. PubMed ID: 24656367
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores.
    Amemiya S; Buhlmann P; Pretsch E; Rusterholz B; Umezawa Y
    Anal Chem; 2000 Apr; 72(7):1618-31. PubMed ID: 10763261
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Polymeric plasticizer extends the lifetime of PVC-membrane ion-selective electrodes.
    Zahran EM; New A; Gavalas V; Bachas LG
    Analyst; 2014 Feb; 139(4):757-63. PubMed ID: 24352534
    [TBL] [Abstract][Full Text] [Related]  

  • 31. New molecularly-imprinted polymer for carnitine and its application as ionophore in potentiometric selective membranes.
    Moret J; Moreira FT; Almeida SA; Sales MG
    Mater Sci Eng C Mater Biol Appl; 2014 Oct; 43():481-7. PubMed ID: 25175239
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ion-Selective Potentiometry with Plasma-Initiated Covalent Attachment of Sensing Membranes onto Inert Polymeric Substrates and Carbon Solid Contacts.
    Choi KR; Honig ML; Bühlmann P
    Anal Chem; 2024 Mar; 96(11):4702-4708. PubMed ID: 38451778
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effects of ion-carrier substituents on the potentiometric-response characteristics in anion-selective membrane electrodes based on iron porphyrins.
    Shahrokhian S; Seifi H; Bagherzadeh M; Mousavi SR
    Chemphyschem; 2004 May; 5(5):652-60. PubMed ID: 15179717
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Synthesis and characterization of bis nitrato[4-hydroxyacetophenonesemicarbazone) nickel(II) complex as ionophore for thiocyanate-selective electrode.
    Chandra S; Hooda S; Tomar PK; Malik A; Kumar A; Malik S; Gautam S
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():18-27. PubMed ID: 26952393
    [TBL] [Abstract][Full Text] [Related]  

  • 35. How fluorous is poly(2,2-bis(trifluoromethyl)-4,5-difluoro-1,3-dioxide-co-tetrafluoroethylene) (Teflon AF)?
    Zhao H; Ismail K; Weber SG
    J Am Chem Soc; 2004 Oct; 126(41):13184-5. PubMed ID: 15479047
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cs+ -selective membrane electrodes based on ethylene glycol-functionalized polymeric microspheres.
    Peper S; Gonczy C; Runde W
    Talanta; 2005 Oct; 67(4):713-7. PubMed ID: 18970229
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The potentiometric behavior of polymer-supported metallophthalocyanines used as anion-selective electrodes.
    Arvand M; Pourhabib A; Shemshadi R; Giahi M
    Anal Bioanal Chem; 2007 Feb; 387(3):1033-9. PubMed ID: 17180336
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cyanex based uranyl sensitive polymeric membrane electrodes.
    Badr IH; Zidan WI; Akl ZF
    Talanta; 2014 Jan; 118():147-55. PubMed ID: 24274282
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Highly Selective Potentiometric Sensing of Biologically Relevant Pyrophosphate and Lysophosphatidic Acid Using
    Li L; Tang J; Liu H; Qian Y
    Anal Chem; 2022 Nov; 94(43):14854-14860. PubMed ID: 36260062
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Synthesis of an ammonium ionophore and its application in a planar ion-selective electrode.
    Benco JS; Nienaber HA; McGimpsey WG
    Anal Chem; 2003 Jan; 75(1):152-6. PubMed ID: 12530832
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.