These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
130 related articles for article (PubMed ID: 19143060)
1. Use of fogarty catheter to limit hemorrhage and hematoma after vacuum-assisted breast biopsy. Zografos GC; Zagouri F; Sergentanis TN; Koulocheri D; Michalopoulos NV; Tsigris C; Bramis J; Gomatos IP Acta Radiol; 2008 Sep; 49(7):752-4. PubMed ID: 19143060 [TBL] [Abstract][Full Text] [Related]
2. Hematoma after vacuum-assisted breast biopsy: a preventable condition? Zografos GC; Zagouri F; Sergentanis TN; Nikiteas N; Gomatos IP Acta Radiol; 2008 Apr; 49(3):277; reply 277. PubMed ID: 18365814 [No Abstract] [Full Text] [Related]
3. Hematoma after vacuum-assisted breast biopsy: are interleukins predictors? Zografos GC; Zagouri F; Sergentanis TN; Koulocheri D; Flessas I; Provatopoulou X; Kalogera E; Michalopoulos NV; Bramis J; Gounaris A Onkologie; 2009 Jul; 32(7):395-7. PubMed ID: 19556816 [TBL] [Abstract][Full Text] [Related]
4. Minimizing underestimation rate of microcalcifications excised via vacuum-assisted breast biopsy: a blind study. Zografos GC; Zagouri F; Sergentanis TN; Nonni A; Koulocheri D; Fotou M; Panopoulou E; Pararas N; Fotiadis C; Bramis J Breast Cancer Res Treat; 2008 May; 109(2):397-402. PubMed ID: 17653855 [TBL] [Abstract][Full Text] [Related]
5. Use of urinary balloon catheter to prevent postoperative bleeding after ultrasound-guided vacuum-assisted breast biopsy. Lian ZQ; Yu HY; Zhang AQ; Xie SM; Wang Q Breast J; 2020 Feb; 26(2):144-148. PubMed ID: 31650650 [TBL] [Abstract][Full Text] [Related]
7. Emergency embolization for breast pseudoaneurysm following vacuum-assisted biopsy: a case report. Binh NT; Duc NM; Tra My TT; Dung LV; Luu DT; Linh LT Pan Afr Med J; 2021; 38():135. PubMed ID: 33912305 [TBL] [Abstract][Full Text] [Related]
8. Vacuum-assisted breast biopsy in nonpalpable solid breast lesions without microcalcifications: the Greek experience. Zografos G; Zagouri F; Sergentanis TN; Nonni A; Koulocheri D; Dardamanis D; Oikonomou V; Giannopoulos P; Kouerinis I; Tsigris C; Bramis J Diagn Interv Radiol; 2008 Sep; 14(3):127-30. PubMed ID: 18814132 [TBL] [Abstract][Full Text] [Related]
9. Pain during vacuum-assisted breast biopsy: are there any predictors? Zografos GC; Zagouri F; Sergentanis TN; Nonni A; Domeyer P; Koulocheri D; Flessas I; Panopoulou E; Chrysikos D; Bramis J Breast; 2008 Dec; 17(6):592-5. PubMed ID: 18657974 [TBL] [Abstract][Full Text] [Related]
10. Haematomas after percutaneus vacuum-assisted breast biopsy. Hertl K; Marolt-Music M; Kocijancic I; Prevodnik-Kloboves V; Zgajnar J Ultraschall Med; 2009 Feb; 30(1):33-6. PubMed ID: 18773386 [TBL] [Abstract][Full Text] [Related]
11. Stereotactic vacuum-assisted breast biopsy: Comparison between 11- and 8-gauge needles. Ruggirello I; Nori J; Desideri I; Saieva C; Giannotti E; Bicchierai G; De Benedetto D; Francolini G; Bianchi S; Vezzosi V; Sanchez L; Susini T; Orzalesi L; Meattini I; Livi L; Miele V Eur J Surg Oncol; 2017 Dec; 43(12):2257-2260. PubMed ID: 29042074 [TBL] [Abstract][Full Text] [Related]
12. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation. Zagouri F; Sergentanis TN; Domeyer P; Chrysikos D; Giannakopoulou G; Michalopoulos NV; Safioleas P; Flessas I; Panopoulou E; Bletsa G; Zografos GC BMC Res Notes; 2010 Mar; 3():70. PubMed ID: 20226029 [TBL] [Abstract][Full Text] [Related]
13. Pain in different methods of breast biopsy: emphasis on vacuum-assisted breast biopsy. Zagouri F; Sergentanis TN; Gounaris A; Koulocheri D; Nonni A; Domeyer P; Fotiadis C; Bramis J; Zografos GC Breast; 2008 Feb; 17(1):71-5. PubMed ID: 17869106 [TBL] [Abstract][Full Text] [Related]
14. Ultrasound demonstration of clip migration to Skin within 6 weeks of 11-gauge vacuum-assisted stereotactic breast biopsy. Parikh J Breast J; 2004; 10(6):539-42. PubMed ID: 15569213 [TBL] [Abstract][Full Text] [Related]
15. Vascular Complications following Vacuum-Assisted Breast Biopsy (VABB): A Case Report and Review of the Literature. Pansa E; Guzzardi G; Santocono S; Carriero A Tomography; 2023 Jun; 9(4):1246-1253. PubMed ID: 37489467 [TBL] [Abstract][Full Text] [Related]
16. Vacuum-assisted breast biopsy: the value and limitations of cores with microcalcifications. Zagouri F; Sergentanis TN; Nonni A; Koulocheri D; Fotou M; Panopoulou E; Panou M; Fotiadis C; Bramis J; Zografos GC Pathol Res Pract; 2007; 203(8):563-6. PubMed ID: 17611039 [TBL] [Abstract][Full Text] [Related]
17. Intraoperative localization after stereotactic breast biopsy without a needle. Smith LF; Henry-Tillman R; Rubio IT; Korourian S; Klimberg VS Am J Surg; 2001 Dec; 182(6):584-9. PubMed ID: 11839321 [TBL] [Abstract][Full Text] [Related]
18. Compression-refractory breast hematoma secondary to pseudoaneurysm after stereotactically guided vacuum-assisted biopsy: the critical role of urgent surgical evacuation. Sun S; Hennessey H; Kam Nakch I; Alsharif S; Meterissian S; Mesurolle B J Clin Ultrasound; 2014 Oct; 42(8):492-4. PubMed ID: 24990329 [TBL] [Abstract][Full Text] [Related]
19. Vacuum-assisted breast biopsy device (mammotome) malfunction simulating microcalcifications. Wahner-Roedler DL; Whaley DH; Brandt KR; Reynolds C Breast J; 2005; 11(6):474-5. PubMed ID: 16297098 [No Abstract] [Full Text] [Related]
20. [Vacuum-assisted breast biopsy for diagnosis of non-palpable lesions: experience with 226 cases]. Nebuloni M; Amadori R; Antonacci C; Rossi RS; Sartani A; De Simone A; Corsi F; Bianco R; Nosenzo MA; Trabucchi E; Vago G Pathologica; 2008 Jun; 100(3):162-5. PubMed ID: 18841819 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]