352 related articles for article (PubMed ID: 19143961)
21. Relationship between inspiratory pressure and tidal volume in the anesthetized canine.
Blumenthal SR; Skoula CM; Gordon BE
Lab Anim Sci; 1998 Feb; 48(1):69-73. PubMed ID: 9517894
[TBL] [Abstract][Full Text] [Related]
22. Can you deliver accurate tidal volume by manual resuscitator?
Lee HM; Cho KH; Choi YH; Yoon SY; Choi YH
Emerg Med J; 2008 Oct; 25(10):632-4. PubMed ID: 18843057
[TBL] [Abstract][Full Text] [Related]
23. Relationship between endotracheal tube leakage and under-reading of tidal volume in neonatal ventilators.
Mahmoud RA; Fischer HS; Proquitté H; Shalaby HM; Schmalisch G
Acta Paediatr; 2009 Jul; 98(7):1116-22. PubMed ID: 19432838
[TBL] [Abstract][Full Text] [Related]
24. Bench performance of ventilators during simulated paediatric ventilation.
Park MA; Freebairn RC; Gomersall CD
Anaesth Intensive Care; 2013 May; 41(3):349-58. PubMed ID: 23659397
[TBL] [Abstract][Full Text] [Related]
25. [Benchmark of a high-frequency jet ventilator, the Monsoon™].
Gueret G; Touffet L; Arvieux CC; Bourgain JL
Ann Fr Anesth Reanim; 2010 Nov; 29(11):821-5. PubMed ID: 20980121
[TBL] [Abstract][Full Text] [Related]
26. Arterial-to-end-tidal carbon dioxide tension difference in children with congenital heart disease.
Choudhury M; Kiran U; Choudhary SK; Airan B
J Cardiothorac Vasc Anesth; 2006 Apr; 20(2):196-201. PubMed ID: 16616659
[TBL] [Abstract][Full Text] [Related]
27. The effects of tidal volume demand on work of breathing during simulated lung-protective ventilation.
Kallet RH; Alonso JA; Diaz M; Campbell AR; Mackersie RC; Katz JA
Respir Care; 2002 Aug; 47(8):898-909. PubMed ID: 12162801
[TBL] [Abstract][Full Text] [Related]
28. [What are the changes in paediatric anaesthesia practice afforded by new anaesthetic ventilators?].
Odin I; Nathan N
Ann Fr Anesth Reanim; 2006 Apr; 25(4):417-23. PubMed ID: 16310339
[TBL] [Abstract][Full Text] [Related]
29. Combining "open-lung" ventilation and arteriovenous extracorporeal lung assist: influence of different tidal volumes on gas exchange in experimental lung failure.
Muellenbach RM; Kredel M; Kuestermann J; Klingelhoefer M; Schuster F; Wunder C; Kranke P; Roewer N; Brederlau J
Med Sci Monit; 2009 Aug; 15(8):BR213-20. PubMed ID: 19644409
[TBL] [Abstract][Full Text] [Related]
30. Measurement of pulsatile tidal volume, pressure amplitude, and gas flow during high-frequency percussive ventilation, with and without partial cuff deflation.
Allan PF; Thurlby JR; Naworol GA
Respir Care; 2007 Jan; 52(1):45-9. PubMed ID: 17194317
[TBL] [Abstract][Full Text] [Related]
31. Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode.
Dellinger RP; Jean S; Cinel I; Tay C; Rajanala S; Glickman YA; Parrillo JE
Crit Care; 2007; 11(1):R26. PubMed ID: 17316449
[TBL] [Abstract][Full Text] [Related]
32. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.
Toyama H; Endo Y; Ejima Y; Matsubara M; Kurosawa S
Anaesth Intensive Care; 2011 Jul; 39(4):599-606. PubMed ID: 21823376
[TBL] [Abstract][Full Text] [Related]
33. [Intraoperative changes in arterial end tidal CO2 partial pressure difference in interventions with constant ventilation-perfusion ratio].
Hillen T; Sümpelmann R; Strauss JM
Anaesthesiol Reanim; 1999; 24(2):37-40. PubMed ID: 10372433
[TBL] [Abstract][Full Text] [Related]
34. Contemporary anesthesia ventilators incur a significant "oxygen cost".
Klemenzson GK; Perouansky M
Can J Anaesth; 2004; 51(6):616-20. PubMed ID: 15197125
[TBL] [Abstract][Full Text] [Related]
35. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
[TBL] [Abstract][Full Text] [Related]
36. Volume guarantee ventilation, interrupted expiration, and expiratory braking.
McCallion N; Lau R; Dargaville PA; Morley CJ
Arch Dis Child; 2005 Aug; 90(8):865-70. PubMed ID: 15886260
[TBL] [Abstract][Full Text] [Related]
37. [Arterial to end-tidal carbon dioxide tension difference during laparoscopic colorectal surgery].
Tanaka T; Satoh K; Torii Y; Suzuki M; Furutani H; Harioka T
Masui; 2006 Aug; 55(8):988-91. PubMed ID: 16910479
[TBL] [Abstract][Full Text] [Related]
38. Expiratory tidal volume displayed on Bird 8400 STi can exceed the preset tidal volume due to cardiogenic oscillation: a lung model study.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
J Anesth; 2004; 18(4):313-5. PubMed ID: 15549478
[TBL] [Abstract][Full Text] [Related]
39. The influence of flow rate on breathing circuit compliance and tidal volume delivered to patients in mechanical ventilation.
Silvestri S
Physiol Meas; 2006 Jan; 27(1):23-33. PubMed ID: 16365508
[TBL] [Abstract][Full Text] [Related]
40. An in vitro evaluation of an instrument designed to measure oxygen consumption and carbon dioxide production during mechanical ventilation.
Weissman C; Sardar A; Kemper M
Crit Care Med; 1994 Dec; 22(12):1995-200. PubMed ID: 7988139
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]